Faria Instruments NMEA2000 user manual

User manual for the device Faria Instruments NMEA2000

Device: Faria Instruments NMEA2000
Category: Automobile Parts
Manufacturer: Faria Instruments
Size: 1.55 MB
Added : 2/26/2013
Number of pages: 44
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Faria Instruments NMEA2000. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Faria Instruments NMEA2000.

For your convenience

If looking through the Faria Instruments NMEA2000 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Faria Instruments NMEA2000 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Faria Instruments NMEA2000 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Faria Instruments NMEA2000 User manual - Online PDF
Advertisement
« Page 1 of 44 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Faria Instruments NMEA2000 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Faria Instruments NMEA2000. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

Owner’s Manual
NMEA2000 MG2000
Tachometer
IS0189
rev. B ecr#6583 12/2006

Summary of the content on the page No. 2

Index Standard Operating Conditions page 1 Description page 1 Figure 1 page 1 Operation page 1 Normal Mode page 2 Display Contrast page 2 Displayed Functions page 3 Default screen 1 page 3 Default screen 2 page 3 Default screen 3 page 4 Default screen 4 page 4 Default screen 5 page 4 Figure 2 Default screens page 5 Figure 3 LCD Display Screens page 6 Edit Mode page 7 Functions that are adjusted in Edit Mode. page 7 Instructions page 8 Select “Default Screen” page 8 Local Fuel

Summary of the content on the page No. 3

Calibrate Trim Sender page 20 Select Display Units page 20 Select “Pressure Units” page 20 Select “Volume Units” page 21 Select “Temperature Units” page 21 Select “Distance Units” page 21 Select “Depth Units” page 21 Fuel Tank Calibration page 22 Low Fuel Alarm Setting page 23 Adjust “Low Fuel Alarm” Setting page 23 Select “Self Test” page 23 Select “Software ID and Revision” page 24 Depth Sounder Warnings page 24 Set Depth Sounder Shallow Warning page 25 Set Depth So

Summary of the content on the page No. 4

Faria KLine mini Gateway PGFXXX Oil Pressure Faria KLine 3650 RPM 20.1 PSI Trim Sync mini Gateway PGFXXX FARIA NMEA 2000 CAN bus Engine Temp MG2000 Tachometer Manual Faria Oil Pressure On Off 136 ˚F 3650 KLine RPM 20.1 PSI Standard Operating Conditions Engine Hours Trim Sync mini 325 Hours Voltage: 12 - 24V 19.3 System, PSI (10.5 – 32 41˚21N 072˚06W Gateway V operating, 36 V max operating, 1 Depth Hr.) 65˚ F 20 Feet P S PGFXXX Temperature: 0° - 158° F Shock Resistant per

Summary of the content on the page No. 5

The Faria MG2000 Tachometer will turn buttons to enter the “Edit” menus. on when the ignition key is turned on and will turn off when the ignition key is turned off. Operation The unit will power up showing the “Self When the “Edit” menus have been Test Mode Is In Operation” then switch to selected, pressing the “Mode” button the last saved default screen. for a short period of time causes the Note: The warning LEDs will flash when instrument to return to “Normal” mode. there is no

Summary of the content on the page No. 6

data directly from the ECU so no settings Faria are required. KLine mini A microprocessor controlled stepper Gateway motor moves the pointer to display engine revolutions per minute. With the display in “Positive” mode, black PGFXXX on white, pressing the “Down” button decreases the contrast. Pressing the Oil Pressure “Up” button increases contrast. 3650 RPM 20.1 PSI Trim Sync Continuing to press the “Up” button causes the display to reverse to the “Negative” mode, white on black. The

Summary of the content on the page No. 7

Faria KLine mini Faria Gateway KLine mini PGFXXX Gateway Oil Pressure PGFXXX 3650 RPM 20.1 PSI Trim Sync Oil Pressure 20.1 PSI 3650 RPM Trim Sync Default Screen “2” on the tachometer. Pressure gauge dial range can be selected in “Edit” mode. Fuel Left On Off 47 Gal Default screen “4” Fuel Used RPM 17.5 Gal 41˚21N 072˚06W 19.3 PSI On Off 3400 Fuel Inst Sen Fuel 65˚ F 11.6 Gal P S 41˚21N 072˚06W 17.5 Gal 19.3 PSI Oil Pressure Fuel Left 65˚ F Displays the quantity of fuel

Summary of the content on the page No. 8

Engine !” or “Engine Emergency Stop Screen “1” !”. Accessing the “View“ mode when the Alarm screen appears will allow more Default information to be displayed about the alarm, if provided by the engine. Screen “2” Internal alarm values can be set for “Low Fuel” and other functions. Alarms for these settings will appear as required. Screen “3” LCD Display Screens: In “Normal” mode, press “Mode” once to enter screen “Select” mode, Screen “4” Screen “5” Alarms (only available if A

Summary of the content on the page No. 9

1. Select Default Screen 2. Local Fuel Configuration 3. Fuel Totalizer Configuration 4. Organize User Screens 5. Select Gauge Range 6. Select Data Sources 7. Calibrate Trim Sender 8. Select Display Units 9. Fuel Tank Calibrate 10. Low Fuel Alarm 11. Select Self Test 12. Software ID & Revision 13. Reset To Defaults 14. Depth Sounder Warnings Page 6

Summary of the content on the page No. 10

Edit Mode The “Edit” mode is used to adjust or set the values of numerous functions and options in the MG2000. The procedure below specifies the steps to be taken in the “Edit” mode to adjust / set each option. To enter “Edit” mode, press “Mode” and “Up” buttons while in “Normal” mode. To return to “Normal” mode, press “Mode” button once while in “Edit” mode. Functions that are set or adjusted in the “Edit” mode. 1. Select Default Screen 2. Local Fuel Configuration 3. Fuel Totalizer Configurati

Summary of the content on the page No. 11

Instructions – Function LINE DISPLAY 1 Select Select Default Screen 2 Default 3 Screen Press and hold “Up” and “Down” for 2 seconds to select “Default Screen.” Press “Up” or “Down” to select another function or “Mode” to return to “Normal” mode. 1 Default 2 Display (Display Screen 1 is the “Default” at first turn on.) 3 Screen: 1 4 Press and hold “Up” and “Down” for 2 seconds to select Screen 1 as the “Default Screen” and exit. Press “Up” or “Down” to select another Screen. 1 Default 2 Displa

Summary of the content on the page No. 12

Press and hold “Up” and “Down” for 2 seconds to reset “Fuel Used” to zero (0). Automatically resets fuel used to zero and returns to “Local Fuel Config” menu. Press “Up” or “Down” to select another function or “Mode” to return to “Edit” mode. 1 Set Set “Fuel Tank Full” 2 Fuel Tank 3 Full NOTE: In order to use the “Fuel Left” function, the owner must set this function when the fuel tank is filled or use the set current amount of fuel below. In addition, if “Set Fuel Tank Full” function is use

Summary of the content on the page No. 13

When the volume is correctly set, Press and hold “Up” and “Down” for 2 seconds to save the value and return to the “Local Fuel Config” mode. Press “Up” or “Down” to select another function or “Mode” to return to “Edit” mode. 1 Select Select “Fuel Tank Size” 2 Fuel Tank 3 Size Press and hold “Up” and “Down” for 2 seconds to enter the “Select Fuel Tank Size” menu or press “Mode” to return to “Edit” mode. 1 Select 2 Standard Select “Standard Fuel Tank Size” 3 Fuel Tank 4 Size Press and hold

Summary of the content on the page No. 14

1 Select Press “Up” or “Down” to set the fuel tank size displayed on the Screen to match your fuel tank size. Line 4 value will 2 Other adjust. 3 Fuel Tank When set, Press and hold “Up” and “Down” for 2 seconds to save the value. XX 4 Press “Up” or “Down” to select a different function or press “Mode” to return to “Local Fuel Config” menu. Press “Up” or “Down” to select a different function or press “Mode” to return to “Edit” mode. 1 Fuel Totalizer Fuel Totalizer Config 2 Config 3 Press and

Summary of the content on the page No. 15

Press and hold “Up” and “Down” for 2 seconds to set “TFuel Tank Full.” Automatically sets the total fuel available to the TFuel tank size selected by the user and returns to “Fuel Totalizer Config” menu. Press “Up” or “Down” to select another function or “Mode” to return to “Edit” mode. 1 Total Total Amount of Fuel 2 Amount of Fuel 3 NOTE: If the known combined amount of fuel is in the fuel tanks but they are not full, this function can be used to indicate the amount of fuel available. The

Summary of the content on the page No. 16

1 Select 2 TFuel Tank Size 3 Press “Up” or “Down” to scroll through the selections. Only three selections will show at one time. 120 Gal 4 > 25 Gal 5 36 Gal 6 40 Gal When the correct choice is next to the selection arrow, 50 Gal Press and hold “Up” And “Down” for 2 seconds to save 55 Gal the selection and return to the “Select Standard TFuel Tank Size” selection 80 Gal 1 Select 2 Other Select “Other TFuel Tank Size” 3 TFuel Tank 4 Size Press and hold “Up” and “Down” for 2 seconds t

Summary of the content on the page No. 17

Press “Up” or “Down” to select a different function or press “Mode” to return to “Edit” mode. 1 Organize Organize User Screens 2 User 3 Screens Press and hold “Up” and “Down” for 2 seconds to select “Organize User Screens.” Press “Up” or “Down” to select another function or “Mode” to return to “Normal” mode. 1 Set up Screen Organize Screen 1 2 1 3 Press and hold “Up” and “Down” for 2 seconds to select “Set Up Screen 1.” Press “Up” or “Down” to select another Screen or “Mode” to return to

Summary of the content on the page No. 18

Repeat for remaining Screens (2, 3, etc) Press “Mode” to return to the “Edit” mode. Press “Up” or “Down” to select another function or “Mode” to return to “Normal” mode 1 Select Select Gauge Range (dial reading range) 2 Gauge Range 3 Press and hold “Up” and “Down” for 2 seconds to “Select Gauge Range.” Press “Up” or “Down” to select another function. 1 Select Select “Oil Pressure Dial” 2 Oil Pressure Dial 3 Press and hold “Up” and “Down” for 2 seconds to select “Oil Pressure Dial.” Press “Up

Summary of the content on the page No. 19

Press and hold “Up” and “Down” for 2 seconds to select “Voltmeter Dial.” Press “Up” or “Down” to select another “Gauge Range.” Press “Mode” to return to “Edit” mode. 1 Select Press “Up” or “Down” to scroll through the selections. 2 Voltmeter When the correct choice is next to the selection arrow, 3 Dial Press and hold “Up” and “Down” for 2 seconds to save the 32 v 4 selection and return to “Gauge Range” selection. > 16 v 5 1 Select Select “Water Pressure Dial” 2 Water Press 3 Dial Pr

Summary of the content on the page No. 20

1 Select Select Data Sources 2 Data Sources 3 Press and hold “Up” and “Down” for 2 seconds to choose “Select Data Sources.” Press “Up” or “Down” to select another function. 1 Set Set “Engine Instance” 2 Engine Instance 3 Press and hold “Up” and “Down” for 2 seconds to select “Set Engine Instance”. ”Press “Up” or “Down” to select another function. Press “Up” or “Down” to set the engine instance. 1 Set 2 Engine Line 5 value will adjust between 0 and 4. 3 Instance When set, press and hold “U


Alternative user manuals
# User manual Category Download
1 Faria Instruments GM/ALDL User manual Automobile Parts 2
2 Faria Instruments J1939 User manual Automobile Parts 1
3 Faria Instruments PILOT IS0152 User manual Automobile Parts 4
4 Faria Instruments Performance IS0218 User manual Automobile Parts 0
5 Faria Instruments IS0135A User manual Automobile Parts 1
6 Faria Instruments MG2000 Speedometer MG2000TM User manual Automobile Parts 0
7 Faria Instruments IS0157 User manual Automobile Parts 0
8 Faria Instruments SMARTCRAFT MG2000 User manual Automobile Parts 10
9 Faria Instruments Speedometer/Depth Sounder User manual Automobile Parts 51
10 Faria Instruments Suzuki User manual Automobile Parts 1
11 Faria Instruments Commander User manual Automobile Parts 1
12 Sony BP-GL95 User manual Automobile Parts 25
13 Sony BP-GL65 User manual Automobile Parts 2
14 Philips Epic 50PF9966 User manual Automobile Parts 3
15 Philips HTS3011 User manual Automobile Parts 2
16 Philips SDJ6040W User manual Automobile Parts 1