Bosch Appliances LTC 8016/90 user manual

User manual for the device Bosch Appliances LTC 8016/90

Device: Bosch Appliances LTC 8016/90
Category: Home Security System
Manufacturer: Bosch Appliances
Size: 0.72 MB
Added : 10/2/2013
Number of pages: 24
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Bosch Appliances LTC 8016/90. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Bosch Appliances LTC 8016/90.

For your convenience

If looking through the Bosch Appliances LTC 8016/90 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Bosch Appliances LTC 8016/90 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Bosch Appliances LTC 8016/90 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Bosch Appliances LTC 8016/90 User manual - Online PDF
Advertisement
« Page 1 of 24 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Bosch Appliances LTC 8016/90 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Bosch Appliances LTC 8016/90. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

LTC 8016/90
Instruction Manual
EN Allegiant Bilinx
Data Interface

Summary of the content on the page No. 2

| LTC 8016/90 | Instruction Manual | Important Safeguards EN 2 Important Safeguards 1. Read, Follow, and Retain Instructions - All safety 10. Power Sources - Operate the unit only from the type and operating instructions should be read and of power source indicated on the label. If unsure of followed before operating the unit. Retain instructions the type of power supply to use, contact your dealer for future reference. or local power company. 2. Heed Warnings - Adhere to all warnings on the un

Summary of the content on the page No. 3

| LTC 8016/90 | Instruction Manual | Safety Precautions EN 3 Safety Precautions For Indoor Product 1. Water and Moisture - Do not use this unit near water - for example, in a wet basement, in an unprotected outdoor installation or in any area classified as a wet location. CAUTION: TO REDUCE THE RISK OF 2. Object and Liquid Entry - Never push objects of ELECTRIC SHOCK, DO NOT REMOVE COVER any kind into this unit through openings, as they (OR BACK). NO USER SERVICEABLE PARTS may touch dangerous vo

Summary of the content on the page No. 4

| LTC 8016/90 | Instruction Manual | FCC & ICES Information EN 4 FCC & ICES INFORMATION Sicherheitshinweise (U.S.A. and Canadian Models Only) This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired VORSICHT: UM EINEN ELEKTRISCHEN SCHLAG ZU operation. VERMEIDEN, IST DIE ABDECKUNG (ODER RÜCKS

Summary of the content on the page No. 5

| LTC 8016/90 | Instruction Manual | Safety Precautions EN 5 Veiligheidsmaatregelen Medidas de Segurança VOORZICHTIG: OPEN DE BEHUIZING OF DE ACHTERKANT CUIDADO: PARA REDUZIR O RISCO DE CHOQUE VAN HET APPARAAT NIET. ZO VERMINDERT U HET RISICO ELÉCTRICO, NÃO RETIRE A TAMPA (OU A PARTE OP ELEKTRISCHE SCHOKKEN. IN HET APPARAAT POSTERIOR). NO INTERIOR, NÃO EXISTEM PEÇAS QUE BEVINDEN ZICH GEEN ONDERDELEN DIE U ZELF KUNT POSSAM SER REPARADAS PELO UTILIZADOR. REMETA A REPAREREN. LAAT SERVICE EN ONDERHO

Summary of the content on the page No. 6

| LTC 8016/90 | Instruction Manual | Table of Contents EN 6 Table of Contents Important Safeguards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2 FCC & ICES Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4 1.0 UNPACKING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Summary of the content on the page No. 7

| LTC 8016/90 | Instruction Manual | Unpacking EN 7 1.0 UNPACKING 3.0 DESCRIPTION This equipment should be unpacked and handled with 3.1 General care. If an item appears to have been damaged in The LTC 8016 Allegiant Bilinx Data Interface Unit shipment, notify the shipper. is an accessory device used to provide two-way communication between a controller and up to Verify that all parts shown in the Parts List have been 16 Bilinx-capable cameras. Full control of included. If any items are missin

Summary of the content on the page No. 8

| LTC 8016/90 | Instruction Manual | Installation EN 8 XF • Any Dinion Series Cameras manufactured 4.2 Connections to AC Power after April 2004. Connect the appropriate power cord to the AC main source. If the cord termination is not suitable for • Any controller device generating Allegiant connection to the main AC supply, modification biphase P/T/Z control code protocol. to the cord, or a locally sourced cord with the correct 4.0 INSTALLATION end style is required. The Allegiant Bilinx Data

Summary of the content on the page No. 9

| LTC 8016/90 | Instruction Manual | Installation EN 9 These switches are used to identify the group of Coax LTC 4630 cameras to be connected to the Interface Unit. Each F/O Module Bilinx-enabled group consists of 16 cameras in consecutive order, AutoDomes Fiber Cable Length 600 m ( 2000 ft) max and the group must always end at an exact multiple of 16. For example, the lowest camera group range Video + Data is from 1 to 16. The next group range is from Typical CAT-5 LTC 4631 17 to 32, etc., u

Summary of the content on the page No. 10

| LTC 8016/90 | Instruction Manual | Installation EN 10 4.4.1 Group ID Settings When Using Allegiant Set the Group ID switches using the supplied screwdriver, as follows: RS-232 or RS-485 Protocol When using the Allegiant data interface protocol, the Group ID Camera Group ID Camera 1 1 Switches Number Switches Number Group ID must be set to correspond to a block of 16 Range Range physical camera numbers between 1-16 and 481-496. 001 1 to 16 017 257 to 272 Since each block consists of 16 numbers

Summary of the content on the page No. 11

| LTC 8016/90 | Instruction Manual | Installation EN 11 4.4.2 Switch Settings When Interfacing to Biphase The Interface Unit is set to 901 by default, and no change is required when only one Interface Unit is Controller Devices When using a biphase data interface, the Group used in a system for cameras 1 to 16. Otherwise, use the supplied screwdriver to set the Group ID ID switches must be set to correspond to a block of 16 logical camera numbers between 1-16 and to correspond to the logical

Summary of the content on the page No. 12

| LTC 8016/90 | Instruction Manual | Installation EN 12 The video connections from the Interface Unit MUST 4.5 Video Connections to be kept in consecutive order, and the group must the Controller Unit always end at an exact multiple of 16. For example, Video connections from the Interface Unit vary based the lowest camera group range is from 1 to 16. The on the type of video connections available on the next group range is from 17 to 32, and so on, up to controller, and the distance between the

Summary of the content on the page No. 13

| LTC 8016/90 | Instruction Manual | Installation EN 13 4.5.2 Video Connections to Products via ends to the video inputs on the rear panel of the controller that corresponds to the physical camera LTC 8508/01 Ribbon-to-BNC Cable Video connections to Allegiant models LTC 8100, number range previously determined by the Group ID switch settings above. For example, if the Group ID LTC 8500, and other products using BNC video connectors, can utilize the 1 m (3 ft) 16-channel switches have been set to

Summary of the content on the page No. 14

| LTC 8016/90 | Instruction Manual | Installation EN 14 IntuiKey Series Keyboard: 4.6 Allegiant Series Switcher Data From the main Allegiant screen, navigate to the User Interface Functions menu screen, then press [Enter User 4.6.1 Allegiant Interface Configurations Command]. Key in 39, then press [Enter]. When using the Allegiant data interface protocol, up LTC 8555 or LTC 8550 Series Keyboard: to 31 Interface Units can be connected to a single Press [USER], key in 39, then press [Enter]. l

Summary of the content on the page No. 15

| LTC 8016/90 | Instruction Manual | Installation EN 15 4.6.2 Allegiant Data Connections Using a Single 4.6.3 Allegiant Data Connections Using Multiple Interface Unit Interface Units Use the supplied 3 m (10 ft) data interface cable to Up to 31 units can be connected to a single connect the Allegiant to the Interface Unit. Connect Allegiant switcher, using a daisychain data interface one end of the cable to the Allegiant port selected in configuration. This provides support for up to the prev

Summary of the content on the page No. 16

| LTC 8016/90 | Instruction Manual | Installation EN 16 To connect the Interface Unit to a biphase controller, connections to simplify connection to multiple attach the biphase data cable from the controller to the Interface Units. If this type of connection is necessary, biphase input terminal block on the rear panel of the remove the termination resistor from the biphase Interface Unit. Use the straight slot end of the supplied output terminal block, and connect another user- offset screwdrive

Summary of the content on the page No. 17

| LTC 8016/90 | Instruction Manual | Typical Configuration Diagrams EN 17 4.8.1 Connecting to DiBos Digital Video Connect one end of the RS-232 data cable to the COM2 port on the DESA, and the other end of the Recorders A RS-232 grade data cable (not supplied) is required cable to the PC port on the Interface Unit. The DESA software must now be configured to send the to connect the DiBos DVR to the LTC 8016 Interface Unit. A Bosch Security System’s S1385 cable can be biphase PTZ commands out of

Summary of the content on the page No. 18

| LTC 8016/90 | Instruction Manual | Typical Configuration Diagrams EN 18 Video + Data Max Cable Lengths: Bilinx-enabled RG-59U = 300 m (1000 ft) AutoDomes Bilinx-enabled RG-6 or RG-11 = 600 m (2000 ft) Dinion Series Cameras Video + Data Video Plus Bidirectional Data Conventional Camera BOSCH Video System Monitors Only BOSCH POWER 16-Channel LTC 8016/90 Video Supplied 16-Channel Data Allegiant Bilinx BOSCH BOSCH Signals LTC 8809 Video Cable Interface Unit BOSCH Prod Mon Clr Shot 1 2 3 4 5 6 7 8

Summary of the content on the page No. 19

| LTC 8016/90 | Instruction Manual | Typical Configuration Diagrams EN 19 Control Data Video Video + Data LTC 8016/90 Allegiant Bilinx Data Interface BOSCH POWER / DATA Bilinx-enabled Additional LTC 8016/90 AutoDomes units can be connected via the Biphase data interface, but full bidirectional functionality will not available Video Plus Bilinx-enabled Bidirectional Data Dinion Series Bilinx-enabled Cameras AutoDome LTC 8016/90 Allegiant Bilinx Data Interface BOSCH POWER / DATA Loop Through Syste

Summary of the content on the page No. 20

| LTC 8016/90 | Instruction Manual | Operation EN 20 video amplitude level drops below 15 IRE. When the 6.0 OPERATION Interface is connected to an Allegiant system using the Once installation is finished, operation of this unit is Allegiant data interface, messages can be sent to the completely automatic. Refer to the applicable section of controller to notify the system of these events. By the manual supplied with the control device and/or default, camera contact alarm input 1 will result in


Alternative user manuals
# User manual Category Download
1 Bosch Appliances 800 User manual Home Security System 2
2 Bosch Appliances 3.21.0002 User manual Home Security System 3
3 Bosch Appliances 500 User manual Home Security System 1
4 Bosch Appliances 00P User manual Home Security System 1
5 Bosch Appliances 100 User manual Home Security System 2
6 Bosch Appliances 8-Dec User manual Home Security System 21
7 Bosch Appliances 2601 User manual Home Security System 0
8 Bosch Appliances 4000 User manual Home Security System 0
9 Bosch Appliances 600 User manual Home Security System 0
10 Bosch Appliances 800 User manual Home Security System 0
11 Bosch Appliances APC-AEC21-UPS1Z User manual Home Security System 2
12 Bosch Appliances 8500 User manual Home Security System 2
13 Bosch Appliances AEC-AEC21-EXT1 User manual Home Security System 5
14 Bosch Appliances 7000 User manual Home Security System 0
15 Bosch Appliances 8008 User manual Home Security System 2
16 3Com 1000BASE-T-GBIC User manual Home Security System 0
17 Sony BRCSDP12 User manual Home Security System 3
18 3Com TECHD-0000000122 User manual Home Security System 1
19 Sony SSC-M354 User manual Home Security System 3
20 Sony DIGITAL 8 DCR-TRV130E User manual Home Security System 9