Cornelius Enduro-200/250 user manual

User manual for the device Cornelius Enduro-200/250

Device: Cornelius Enduro-200/250
Category: Beverage Dispenser
Manufacturer: Cornelius
Size: 0.21 MB
Added : 4/21/2014
Number of pages: 17
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Cornelius Enduro-200/250. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Cornelius Enduro-200/250.

For your convenience

If looking through the Cornelius Enduro-200/250 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Cornelius Enduro-200/250 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Cornelius Enduro-200/250 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Cornelius Enduro-200/250 User manual - Online PDF
Advertisement
« Page 1 of 17 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Cornelius Enduro-200/250 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Cornelius Enduro-200/250. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

www.cornelius.com
Installation Manual
ICE/BEVERAGE DISPENSER
Model: Enduro-200/250
IMPORTANT:
TO THE INSTALLER.
It is the responsibility of
the Installer to ensure that
the water supply to the
dispensing equipment is
provided with protection
against backflow by an air
gap as defined in
ANSI/ASME A112.1.2-1979;
or an approved vacuum
breaker or other such
method as proved effective
by test.
Water pipe connections
and fixtures directly
connected to a potable
water supply shall be
sized, installed,

Summary of the content on the page No. 2

TABLE OF CONTENTS Page SAFETY PRECAUTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 DESCRIPTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 SPECIFICATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 INSTALLATION INSTRUCTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Summary of the content on the page No. 3

SAFETY PRECAUTIONS Always: Disconnect power to the dispenser before servicing or cleaning. Never: Place hands inside of hopper or gate area without disconnecting power to the dispenser. Agitator rotation occurs automatically when dispenser is energized! This ice dispenser has been specifically designed to provide protection against personal injury and eliminates contamination of ice.To insure continued protection and sanitation, observe the following: ALWAYS: Be sure the removable lid is proper

Summary of the content on the page No. 4

INSTALLATION INSTRUCTIONS 1. Locate the dispenser indoors on a level counter top. A. LEG OPTION Note: Before installing legs, the plastic plugs must be removed. Unpack the four (4) legs and install them into the threaded holes provided in the bottom of the unit. The installer must provide flexibility in the product and utility supply lines to permit shifting the position of the dispenser sufficiently to clean the area beneath it. Rotate the line support bracket, located under base, to the down p

Summary of the content on the page No. 5

GATE RESTRICTOR PLATE ADJUSTMENT CAUTION: Disconnect power to dispenser before installing, removing or adjusting restrictor. The restrictor plate may be adjusted up or down as shown in Figure 2 to reduce or increase the ice dispensing rate, especially desirable when using glasses or other containers with small openings. Adjustment can be made by sliding the restrictor plate up or down with nuts loosened, to obtain the desired ice dispensing rate. SOLVENT BOND HOSE CLAMP DRIP TRAY DRAIN FITTING

Summary of the content on the page No. 6

INSTALL PLATE ON STUDS AS SHOWN FIGURE 2. GATE RESTRICTOR PLATE 7/16 DIA. 30 1 13/16 26 7/16 1 5/16 12 9 18 5/8 21 1/4 30 11/16 29 23 1/16 3 1/2 9 3/16 11 5/8 Z Style 23 REMOVABLE SINK TO FRONT OF DRIP RECOMMENDED COUNTER OPENING SIZE TRAY ON COUNTERTOP 9 X 12 FOR UTILITIES AND BEVERAGE TUBING. OPENING CAN BE LOCATED TO FRONT TOP ANYWHERE WITHIN SHADED AREA. OF DRIP TRAY FIGURE 3. MOUNTING TEMPLATE 92181INS 4

Summary of the content on the page No. 7

12 34 FAUCETS VIEWED FROM THIS SIDE FIGURE 4. FLOW DIAGRAM (UNIT WITH SIX FAUCETS) 5 92181INS Non–Carb Water OPTIONAL FAUCETS PRESSURE REGULATOR 1 W1 S1 POTABLE INSTALL FOR WATER 2 NON–CARB AS FILTER SUPPLY REQUIRED S2 CHECK CARBONATOR VALVE W2 3 CO2 S3 Carb Water S1 S2 S3 W1 W2 COLDPLATE W3 INLET CONNECTIONS W4 S4 S5 S6 4 OPTIONAL FOR W4 S4 DIET DRINK DRINKS OR ROOT BEER 5 5–15 S5 PSIG W3 6 S6 SYRUP TANKS COLD PLATE 15–50 PSIG S6 S5 S4 S3 S2 S1 PRESSURE REGULATORS FLAVOR F1 F2 F3 F4 TANKS 25–30

Summary of the content on the page No. 8

12 34 FAUCETS VIEWED FROM THIS SIDE FIGURE 5. FLOW DIAGRAM (UNIT WITH EIGHT FAUCETS) 92181INS 6 Non–Carb Water Carb Water FAUCETS OPTIONAL PRESSURE REGULATOR 1 CHECK S1 VALVE POTABLE WATER W1 2 FILTER SUPPLY S2 CARBONATOR INSTALL FOR 3 NON–CARB AS S3 W2 REQUIRED CO2 4 S4 S1 Carb Water S2 S3 S4 W1 W2 COLDPLATE INLET W3 CONNECTIONS W4 S5 S6 S7 S8 OPTIONAL FOR 5 DIET DRINKS S5 OR ROOT BEER W4 5–15 6 PSIG S6 CO2 7 Cylinder W3 S7 8 S8 S7 S6 S5 S4 S3 S2 S1 S8 SYRUP TANKS COLD PLATE 15–50 PSIG PRESSURE

Summary of the content on the page No. 9

123 4 FAUCETS VIEWED FROM THIS SIDE FIGURE 6. FLOW DIAGRAM (UNIT WITH TEN FAUCETS) 7 92181INS Non–Carb Water Carb Water FAUCETS OPTIONAL PRESSURE 1 REGULATOR S1 POTABLE WATER 2 W1 SUPPLY S2 FILTER CARBONATOR 3 INSTALL FOR S3 NON–CARB AS CHECK W2 REQUIRED 4 VALVE S4 CO2 5 S5 S1 Carb Water S2 S3 S4 S5 W1 W2 COLDPLATE W3 INLET CONNECTIONS W4 S6 S7 S8 S9 S10 6 S6 7 OPTIONAL FOR W4 DIET DRINKS S7 OR ROOT BEER 5–15 PSIG S10 S9 S8 S7 S6 S5 S4 S3 S2 S1 8 S8 SYRUP TANKS W3 15–50 PSIG PRESSURE 9 S9 REGULA

Summary of the content on the page No. 10

1234 FAUCETS VIEWED FROM FRONT OF UNIT FIGURE 7. FLOW DIAGRAM (”B” UNIT WITH EIGHT BEVERAGE FAUCETS) 92181INS 8 REGULATORS REGULATOR FOR DIET OR ROOT BEER 5–15 PSIG 15–50 PSIG 1 FAUCETS 2 SYRUP CO TANK 1 S1 S2 S3 S4 S5 S6 S7 S8 2 TANKS S1 3 2 S2 4 3 S3 5 4 S4 6 5 S5 7 6 S6 8 7 S7 FLAVOR WATER * F1 F2 F3 F4 TANKS 8 30 PSIG S8 CW CO2 60–100 PSIG CARB WATER MANIFOLD WATER CHECK OPTIONAL CW VALVE PRESSURE REGULATOR REMOTE POTABLE REFRIGERATION WATER SYSTEM SUPPLY CARBONATOR FILTER ITEMS OUTSIDE BRO

Summary of the content on the page No. 11

BLK 9 92181INS MOTOR T’STAT LIGHT HEATER AGITATOR CAP WIRING DIAGRAM MOTOR 1 2 BLUE GRN ICE LEVEL SIGNAL R Y N OPTION Q.C. CONNECTOR E E L D L SERVICE INFORMATION TO 24V TO BEVERAGE VALVES TRANSFORMER TO HINGE ELECTRIC SHOCK HAZARD. DISCONNECT DISPENSE KEY SWITCH GATE DANGER! POWER BEFORE SERVICING UNIT. SWITCH SOLENOID (106VDC) BLUE YELLOW R OPTIONAL G WB R Y G B B B E E LIGHT BALLAST R H L L L E R L G G D I D E A E A A A L R R T E C E CCC E BEVERAGE BEVERAGE L E BLACK BLACK N E K TRANSFORMER T

Summary of the content on the page No. 12

G L N TIMER L2 L1 RECTIFIER MOTOR HEATER AGITATOR MOTOR 3 N.O. O/L R C 2 4 S VEND SWITCH START CAPACITOR N.C. CAPACITOR MOTOR START RELAY GATE SOLENOID BALLAST LIGHT STARTER OPTIONAL BEVERAGE TRANSFORMER OPTIONAL FLAVOR VLVS OPTIONAL LOW ICE LEVEL LIGHT T’STAT PCB VLV BOARD KEYPAD SOLENOIDS OPTIONAL OPTIONAL BEVERAGE BEVERAGE VALVES VALVES BEVERAGE PANEL FIGURE 9. SCHEMATIC (115 VOLT UNIT) 92181INS 10

Summary of the content on the page No. 13

FLAVOR SOLENOIDS 12 34 BLK 11 92181INS WIRING DIAGRAM SERVICE INFORMATION (220–240 VAC) ELECTRIC SHOCK HAZARD. DISCONNECT DANGER! POWER BEFORE SERVICING UNIT. MOTOR T’STAT LIGHT HEATER AGITATOR B B TO L MOTOR 2 L BEVERAGE 1 U K E BROWN 1 BLUE PANEL POWER BLK ICE LEVEL SIGNAL E SWITCH YEL OPTION N PCB BOARD BROWN Q.C. CONNECTOR L BLU 2 RED BRN TO BEVERAGE VALVES TO 24V TRANSFORMER WHT TO HINGE 3 GUSSET DISPENSE KEY SWITCH KEYPAD WHT GATE SWITCH SOLENOID BLK ESD 4 BLUE (WATER–5) YELLOW GRN/YEL FLA

Summary of the content on the page No. 14

G L N EMI FILTER LINE FILTER TIMER L2 L1 RECTIFIER MOTOR HEATER POWER SWITCH AGITATOR MOTOR 3 N.O. O/L R C 2 4 S VEND SWITCH START CAPACITOR N.C. MOTOR START RELAY GATE SOLENOID OPTIONAL BALLAST OPTIONAL LIGHT OPTIONAL STARTER OPTIONAL BEV. TRANSFORMER OPTIONAL BEV. TRANSFORMER OPTIONAL FLAVOR VLVS PCB VLV BOARD KEYPAD SOLENOIDS BEV. FAUCETS BEVERAGE PANEL FIGURE 11. SCHEMATIC (220–240 VOLT UNIT) 92181INS 12

Summary of the content on the page No. 15

TROUBLESHOOTING IMPORTANT: Only qualified personnel should service internal components or electrical wiring. WARNING: If repairs are to be made to a product system, remove quick disconnects from the applicable product tank, then relieve the system pressure before proceeding. If repairs are to be made to the CO system, stop dispensing, shut off the CO supply, then relieve the 2 2 system pressure before proceeding. If repairs are to be made to the refrigeration system, make sure electrical powe

Summary of the content on the page No. 16

Trouble Probable Cause BEVERAGE NOT SWEET ENOUGH. A.Empty syrup tank. B.Faucet brix requires adjusting. BEVERAGES NOT COLD (UNITS WITH BUILT-IN A.Unit standing with no ice in hopper or no ice in cold COLD PLATE). plate cabinet. FLAVOR SYRUPS DO NOT DISPENSE. A.No 24 volt power to PC board. B.No CO2 pressure. C.Empty syrup tank. D.Kinked tubing. E.Clogged inner nozzle. F. Defective PC board. G.Defective harness from keypad. H.Defective Flow control. I. Defective solenoid harness. J. Defective key

Summary of the content on the page No. 17

WARRANTY IMI Cornelius Inc. warrants that all equipment and parts are free from defects in material and workmanship under normal use and service. For a copy of the warranty applicable to your Cornelius product, in your country, please write, fax or telephone the IMI Cornelius office nearest you. Please provide the equipment model number and the date of purchase. IMI Cornelius Offices AUSTRALIA  P.O. 210,  RIVERWOOD,  NSW 2210, AUSTRALIA  (61) 2 533 3122  FAX (61) 2 534 2166 AUSTRIA  AM LAN


Alternative user manuals
# User manual Category Download
1 Cornelius 1522 User manual Beverage Dispenser 12
2 Cornelius 318569000 User manual Beverage Dispenser 1
3 Cornelius 2232MS User manual Beverage Dispenser 0
4 Cornelius 318948000 User manual Beverage Dispenser 1
5 Cornelius 318949000 User manual Beverage Dispenser 25
6 Cornelius 569000261 User manual Beverage Dispenser 0
7 Cornelius 18368 User manual Beverage Dispenser 0
8 Cornelius 230 VAC User manual Beverage Dispenser 2
9 Cornelius 2 Flavor Post-Mix Cold Coffee Dispenser Quest 2000 User manual Beverage Dispenser 1
10 Cornelius 569000262 User manual Beverage Dispenser 0
11 Cornelius 326142000 User manual Beverage Dispenser 2
12 Cornelius 50Hz User manual Beverage Dispenser 1
13 Cornelius 560003869 User manual Beverage Dispenser 0
14 Cornelius 560003870 User manual Beverage Dispenser 0
15 Cornelius A8531 User manual Beverage Dispenser 0
16 Sony KDL-40V4100 User manual Beverage Dispenser 4
17 Sony KDL-46V4100 User manual Beverage Dispenser 2
18 Sony KDL-40W4100 User manual Beverage Dispenser 3
19 Sony KDL-40V4150 User manual Beverage Dispenser 2
20 Sony KDL-46W4150 User manual Beverage Dispenser 1