ACTiSYS ACT-IR100SD user manual

User manual for the device ACTiSYS ACT-IR100SD

Device: ACTiSYS ACT-IR100SD
Category: Network Card
Manufacturer: ACTiSYS
Size: 0.74 MB
Added : 11/16/2013
Number of pages: 17
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for ACTiSYS ACT-IR100SD. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with ACTiSYS ACT-IR100SD.

For your convenience

If looking through the ACTiSYS ACT-IR100SD user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual ACTiSYS ACT-IR100SD on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual ACTiSYS ACT-IR100SD to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
ACTiSYS ACT-IR100SD User manual - Online PDF
Advertisement
« Page 1 of 17 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual ACTiSYS ACT-IR100SD but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to ACTiSYS ACT-IR100SD. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1



The Wireless Connectivity Expert

48511 Warm Springs Blvd., Suite 206, Fremont CA 94539
Tel: +1-510-490-8024 Fax: +1-510-623-7268
Website: http://www.actisys.com/ E-mail: irda-info@actisys.com
ACT-IR100SD OBEX Server
IrReady Intelligent Adapter
User’s Manual


October 30, 2006
Ver. 1.0

© Copyright 2000-2006 ACTiSYS Corporation
All Rights Reserved

Summary of the content on the page No. 2

ACT-IR100SD OBEX Server The Wireless Connectivity Expert User’s Manual TABLE OF CONTENTS REVISION HISTORY ............................................................................................... 3 PRECAUTIONS ........................................................................................................ 4 1. FEATURES ................................................................................................................ 5 2. OVERVIEW.......................

Summary of the content on the page No. 3

ACT-IR100SD OBEX Server The Wireless Connectivity Expert User’s Manual REVISION HISTORY Revision History Revision Date Comment 1.0 10/30/2006 Draft Preliminary Design Specification.  Copyright 2000-2006 ACTiSYS Corp. Page 3 of 17 Oct 30, 2006 Version 1.0

Summary of the content on the page No. 4

ACT-IR100SD OBEX Server The Wireless Connectivity Expert User’s Manual PRECAUTIONS To ensure trouble-free operation, please observe the following precautions: Optical communications are easily affected by external light sources, weak batteries, transfer distance, transfer angle, etc. Any of these conditions may cause a data transfer failure, incomplete or missing data. Make sure that the wireless interface is away from direct sunlight and other strong light source. Do not ter

Summary of the content on the page No. 5

ACT-IR100SD OBEX Server The Wireless Connectivity Expert User’s Manual 1. FEATURES A complete IrDA Protocol stack in a dongle. Supports both IrDA Primary and Secondary mode, changeable via PC utility. No driver program is needed. Supports mandatory IrDA layer: IrPHY, IrLAP, IrLMP and IAS. Supports upper layers TinyTP, IrCOMM, IrLPT, and OBEX PUT/GET server. Supports host baud rate from 1.2 kbps to 115.2 kbps, which is changeable by PC utility. IrDA baud rate from 9.6 kbps to 11

Summary of the content on the page No. 6

ACT-IR100SD OBEX Server The Wireless Connectivity Expert User’s Manual 2. OVERVIEW The ACT-IR100SD is a high-integration IrDA Intelligent dongle. It provides a serial interface to a host device that intends to have Infrared communication capability. The host device can be any equipment or device that needs to communicate with IrDA enabled portable or tablet PC, PDA, cellphone and hand held data terminal, via IrDA protocol with only a wired serial interface. The ACT-IR100SD will handle

Summary of the content on the page No. 7

ACT-IR100SD OBEX Server The Wireless Connectivity Expert User’s Manual 3. ARCHITECTURE OF ACT-IR100SD The mandatory IrDA protocol layers, IrLAP and IrLMP (including IAS) are handled by ACT-IR100SD, In addition, TinyTP, IrCOMM, IrLPT and OBEX transport are also included. The incoming/outgoing IrDA user data payload are buffered and then transferred to/from the host. The baud rates of IrDA traffic and host interface are independent of each other. The flow controls of IrDA traffic an

Summary of the content on the page No. 8

ACT-IR100SD OBEX Server The Wireless Connectivity Expert User’s Manual 4. HOST INTERFACE The host interface of ACT-IR100SD is a full-duplex asynchronous RS232 DB9M connector. The following table is the signals of DB9M connector. It can be treated as DTE. The data bytes are transmitted via TXD pin and received via RXD. Each data byte consists of one start bit (0), 8 data bits (LSB first, MSB last), a stop bit (1) and no parity bit. Implementing H/W flow control signals in host end is r

Summary of the content on the page No. 9

ACT-IR100SD OBEX Server The Wireless Connectivity Expert User’s Manual 4.1 Host Interface Signals ACT-IR100SD host interface consists of three output signals and five input signals. All these signals are low active. That is, they are at 0V when active and at VCC level when inactive. When an inverting RS232 level converter is used, the corresponding RS232 level signals are high active. That is, they are at +12V nominal when active and at –12V nominal when inactive. 4. /TXD: serial dat

Summary of the content on the page No. 10

ACT-IR100SD OBEX Server The Wireless Connectivity Expert User’s Manual 5. OPERATING IN ACT-IR100SD 5.1 How To Connect IR100SD With Host Device: IR100SD uses a standard RS232 DTE port to connect with the host. If the host device is a Modem like device and has a RS232 DCE port, then use a "straight cable". That is, connect the signals with the same name from one side to the other. All the operating procedures of IR100SD are triggered by DSR signal from HOST, (DSR for IR100SD is an i

Summary of the content on the page No. 11

ACT-IR100SD OBEX Server The Wireless Connectivity Expert User’s Manual 5.2.1 The first page is to set the host baud rate and the hardware flow control. Please Note: Ignore CTS: If host device has no hardware flow control signals, only Tx, Rx and GND, then you have to set this bit to 1. IR100SD will pass the coming data to host and doesn’t care the status of CTS. Note: Since IR100SD is a buffer limited dongle (2K bytes for host and 2K bytes for IrDA), if this bit is set, then it will

Summary of the content on the page No. 12

ACT-IR100SD OBEX Server The Wireless Connectivity Expert User’s Manual 5.2.2 The second page is to set time interval of discovery, the slot number of discovery and the mode of IR100SD. 1) IR100SD supports both Primary and Secondary. It allows customer to change it. 2) Discovery time should be 3 seconds in general. If you want the discovery process faster, you can change it. 3) Discovery slot can also make discovery process faster.  Copyright 2000-2006 ACTiSYS Corp. Page 12 of

Summary of the content on the page No. 13

ACT-IR100SD OBEX Server The Wireless Connectivity Expert User’s Manual 5.2.3 The third page is to set the IrDA protocols when IR100SD is in Primary.  Copyright 2000-2006 ACTiSYS Corp. Page 13 of 17 Oct 30, 2006 Version 1.0

Summary of the content on the page No. 14

ACT-IR100SD OBEX Server The Wireless Connectivity Expert User’s Manual 5.3 OBEX PUT/GET Description The OBEX specification consists of two major parts: a protocol and an application framework. This is also illustrated graphically below. The "application framework" is represented in ellipses inside the "wide word of applications" at the upper half of this figure. The "protocol" part is presented in five rectangles at the lower half of this figure. Standard ACT-IR100SD doesn’t and ca

Summary of the content on the page No. 15

ACT-IR100SD OBEX Server The Wireless Connectivity Expert User’s Manual The following figure shows how cellphone or PDA delivers an object (maybe a phone book record, a picture or a formatted data) to user’s host. When IR100SD-OBEX-Server receives OBEX PUT command, it will act like a PUT server and reply proper response. Then it will trim PUT commands sent by cellphone, only left object data itself and then pass to user’s host. While transferring objects, user’s host is not able to kno

Summary of the content on the page No. 16

ACT-IR100SD OBEX Server The Wireless Connectivity Expert User’s Manual Frame length means total frame size, including byte 0,1,2, and 3. For example, if data frame is 300 bytes, length should be 304. 6. THE DEFAULT SETTING OF ACT-IR100SD The default setting of ACT-IR100SD is configured as the following: Parameters Setting Host baud rate and data format: 115.2 kbps, 8N1 DSR/CTS Not ignored Device role mode Primary/Secondary both Discovery period 3 seconds Discovery slots 6 Pr

Summary of the content on the page No. 17

ACT-IR100SD OBEX Server The Wireless Connectivity Expert User’s Manual 7. ACT-IR100SD DONGLE DIMENSIONS 8. CHARACTERISTICS AND SPECIFICATION Parameter Min. Typical Max. Units DC supply voltage 6.0 7.5 12 V Supply voltage, VSS 0 V Operating temperature range, TA 0 60 ℃ DC current (Ready mode) 40 mA DC current (Active mode) 50 150 mA Infrared Transmitting range 158 200 cm RS232 signal threshold level +/-3 +/-6 +/-12 V  Copyright 2000-2006 ACTiSYS Corp. Page 17


Alternative user manuals
# User manual Category Download
1 ACTiSYS ACT-IR100M User manual Network Card 0
2 ACTiSYS ACT-IR100S User manual Network Card 1
3 ACTiSYS ACT-100MP User manual Network Card 2
4 ACTiSYS ACT-IR100M+ User manual Network Card 0
5 ACTiSYS ACT-100M User manual Network Card 1
6 ACTiSYS ACT IR2000UL User manual Network Card 25
7 ACTiSYS ACT-IR320L User manual Network Card 0
8 ACTiSYS ACT-IR210L User manual Network Card 8
9 ACTiSYS ACT-IR8250SW User manual Network Card 0
10 ACTiSYS IrDA PC Adapter ACT-IR220L+/220L/200L User manual Network Card 24
11 ACTiSYS IrDA IR Printer Adapter ACT-IR100MP User manual Network Card 1
12 ACTiSYS RS232 User manual Network Card 0
13 ACTiSYS ACT IR100SLM User manual Network Card 1
14 Sony BTA-NW1A User manual Network Card 2
15 Sony BKMW-E3000 User manual Network Card 2
16 Sony AC-SQ950D User manual Network Card 0
17 Sony BBV RX100 User manual Network Card 3
18 Sony CLIE A-AVZ-100-11 User manual Network Card 1