Acer PCI to Ultra 160 SCSI RAID Controller AcceleRAID 170 user manual

User manual for the device Acer PCI to Ultra 160 SCSI RAID Controller AcceleRAID 170

Device: Acer PCI to Ultra 160 SCSI RAID Controller AcceleRAID 170
Category: Network Card
Manufacturer: Acer
Size: 6.2 MB
Added : 11/16/2013
Number of pages: 86
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Acer PCI to Ultra 160 SCSI RAID Controller AcceleRAID 170. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Acer PCI to Ultra 160 SCSI RAID Controller AcceleRAID 170.

For your convenience

If looking through the Acer PCI to Ultra 160 SCSI RAID Controller AcceleRAID 170 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Acer PCI to Ultra 160 SCSI RAID Controller AcceleRAID 170 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Acer PCI to Ultra 160 SCSI RAID Controller AcceleRAID 170 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Acer PCI to Ultra 160 SCSI RAID Controller AcceleRAID 170 User manual - Online PDF
Advertisement
« Page 1 of 86 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Acer PCI to Ultra 160 SCSI RAID Controller AcceleRAID 170 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Acer PCI to Ultra 160 SCSI RAID Controller AcceleRAID 170. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

Summary of the content on the page No. 2

Summary of the content on the page No. 3

AcceleRAID™ 170 PCI to Ultra 160 SCSI RAID Controller Installation Guide Part Number 775064-01 08P4093 © Copyright 2000 Mylex Corporation. All Rights Reserved. All contents of this manual are copyrighted by Mylex Corporation. The information contained herein is the exclusive property of Mylex Corporation and shall not be copied, transferred, photocopied, translated on paper, film, electronic media, or computer-readable form; or otherwise reproduced in any way, without the express written

Summary of the content on the page No. 4

Greetings Thank you for purchasing the Mylex AcceleRAID™ 170 disk array controller. Requests for technical information about this and other Mylex Corporation products should be made to your Mylex authorized reseller or Mylex marketing representative. Please Notice IBM, Mylex, AcceleRAID, Global Array Manager (GAM), and RAID EzAssist are trademarks or registered trademarks of International Business Machines Corp. and its subsidiaries. Microsoft, MS-DOS, Windows 95, Windows 98, Windows NT, an

Summary of the content on the page No. 5

About This Manual This installation guide covers hardware set-up and configuration procedures necessary for the installation of a Mylex AcceleRAID 170 single channel RAID controller. Chapter 1 describes the controller, standard package contents, and user- supplied items necessary for installation. Chapter 2 describes the steps to be performed prior to controller installation and the physical installation of the AcceleRAID 170 single channel RAID controller. Chapter 3 describes controller sta

Summary of the content on the page No. 6

Conventions Throughout the manual, the following conventions are used to describe user interaction with the product: prompt This style of type indicates screen display messages Enter Press the key labeled “Enter” (or “Delete,” etc.) ☛ Note Supplementary information that can have an effect on system performance  Caution Notification that a proscribed action has the potential to adversely affect equipment operation, system performance, or data integrity  WARNING Notification that a proscribe

Summary of the content on the page No. 7

Contents Chapter 1 Introduction Product Description ........................................................................... 1-1 Controller Features .................................................................... 1-2 Channel Capabilities .................................................................. 1-2 Controller Capabilities ................................................................ 1-2 Operating System Support ......................................................... 1-3 Sta

Summary of the content on the page No. 8

Chapter 3 Controller Start-up BIOS Options .....................................................................................3-1 Setting BIOS Options .................................................................3-2 BIOS Configuration Utility (RAID EzAssist) .......................................3-4 Operating System ..............................................................................3-4 Operating System Device Drivers ......................................................3-4 Glo

Summary of the content on the page No. 9

Appendix E Regulatory Information Class B Compliance ..........................................................................E-1 Declaration of Conformity ..................................................................E-2 Declaration of Conformity ..................................................................E-3 Community of Europe ........................................................................E-4 Underwriters Laboratories Statement and Warning ..........................E-5 Glo

Summary of the content on the page No. 10

viii AcceleRAID 170 Installation Guide

Summary of the content on the page No. 11

Chapter 1 Introduction This chapter describes:  The AcceleRAID™ 170 controller  Standard package contents  User supplied items Figure 1-1. AcceleRAID 170 Controller Product Description The Mylex AcceleRAID 170 controller is a PCI to Ultra 160 SCSI single channel RAID controller with 32-bit, 33MHz PCI capability. The AcceleRAID 170 supports one external connector and one internal Ultra 160 SCSI connector. The AcceleRAID 170 controller provides the speed and functionality required by high

Summary of the content on the page No. 12

Product Description Controller Features Features of the AcceleRAID 170 controller include:  One QLogic ISP 10160A chip to support one Ultra 160 SCSI LVD channel  Intel i960RM RISC processor operating at 100MHz  32MB, 64MB, and 128MB ECC cache DIMM module  PCI 2.2 compliant  1MB, 8-bit flash EEPROM for BIOS and code  Built-in configuration utilities (in BIOS)  Write-through and write-back cache support  PCI Hotplug capability allows the AcceleRAID 170 to be swapped with a replaceme

Summary of the content on the page No. 13

Introduction Operating System Support MS-DOS 5.x, 6.x, and above are supported using drivers that reside in the AcceleRAID BIOS. Many drivers in the Disk Array Controller Software Kit, included with the AcceleRAID 170 controller, support many other popular operating systems (see the PCI Disk Array Controller Drivers Installation Guide and User Manual). Manual No. 775064 1-3

Summary of the content on the page No. 14

Standard Package Contents Standard Package Contents The following items are supplied with the standard shipping package: Hardware  AcceleRAID 170 Disk Array Controller with documentation included on the CD-ROM and a printed Quick Installation Guide  Standard DIMM Module: 32MB, 64MB, or 128MB (ECC) Software  On-board RAID EzAssist disk array controller configuration utility with documentation on CD-ROM and a printed Quick Configuration Guide  Software Kit Driver diskettes with documentati

Summary of the content on the page No. 15

Introduction User-supplied Items The following user-supplied items are required to perform this installation:  IBM-PC™ compatible host system with PCI slot (PCI 2.2 compliant)  Network operating system software (as required)  SCSI cables to connect the controller and disk arrays  Static grounding strap or electrostatic discharge (ESD) safe work area  Disk array enclosure (or equivalent) with SCSI disk drives Manual No. 775064 1-5

Summary of the content on the page No. 16

User-supplied Items 1-6 AcceleRAID 170 Installation Guide

Summary of the content on the page No. 17

Chapter 2 Installation This chapter describes:  Before You Begin  Safety Considerations  Installation Checklist  Connectors, LEDs, Jumpers  Installation Process (controller)  SCSI Termination  SCSI IDs  SCSI Cabling  Limitations on Mixing SCSI Drives Mylex disk array controllers are designed to work in a variety of SCSI RAID application environments. Certain configuration steps need to be performed prior to installing the controller into a RAID environment. Each of the steps descri

Summary of the content on the page No. 18

Before You Begin Before You Begin Installing the AcceleRAID 170 single channel RAID controller is no more difficult than installing any 32-bit PCI adapter controller. The AcceleRAID 170 single channel controller connects into any PCI 2.2 compliant slot on the motherboard. Follow these steps and the installation procedures in this chapter. ☛ Note Recommended: Connect the AcceleRAID 170 into a 32-bit PCI slot to reserve the 64-bit PCI slot for 64-bit controllers (although the AcceleRAID 170

Summary of the content on the page No. 19

Installation Safety Considerations Be sure to observe the following precautions before beginning the controller installation procedure:  Caution Anti-static handling procedures are required. Leave the controller in its anti-static bag until it is time to plug the controller into the PCI slot. The use of a grounded wrist strap and other ESD protective measures are highly recommended.  WARNING Disconnect the system from the electrical wall outlet before opening the system cabinet. Working

Summary of the content on the page No. 20

Installation Checklist Installation Checklist GET READY ☛ Note It is recommended that you wear a grounded wrist strap when performing hardware installation procedures. 1. ____ Power off your computer system. 2. ____ Decide which available PCI slot will be used. 3. ____ Remove the plate from the I/O access port to the PCI slot. 4. ____ Remove the AcceleRAID 170 controller from the anti-static bag. GET SET ☛ Note Review Figure 2-1, Figure 2-2, and Figure 2-3; Table 2-1 and Table 2-2 to get fa


Alternative user manuals
# User manual Category Download
1 Acer PCI Disk Array Controller Drivers 08P4100 User manual Network Card 1
2 Acer Altos R300 User manual Network Card 1
3 Acer MegaRAID SCSI 320-0 Zero-Channel RAID Controller Series 520 User manual Network Card 0
4 Acer IEEE 802.11b Wireless USB Adapter User manual Network Card 7
5 Acer Network Device Altos R520 User manual Network Card 2
6 Acer ISDN P10 User manual Network Card 1
7 Acer PCI to Ultra SCSI RAID Controllers DAC960PG User manual Network Card 1
8 Acer G301 User manual Network Card 1
9 Acer PCI to Ultra SCSI RAID Controllers DAC960PJ User manual Network Card 1
10 Acer WT 300 User manual Network Card 2
11 Acer AcceleRAIDTM 352 PCI to Ultra 160 SCSI RAID Controller AcceleRAID 352 User manual Network Card 13
12 Acer ALN-201 User manual Network Card 6
13 Acer IEEE 802.11b WLAN PC Card User manual Network Card 1
14 Acer Altos R500 User manual Network Card 1
15 Acer Modemconte User manual Network Card 1
16 Sony BTA-NW1A User manual Network Card 2
17 Sony BKMW-E3000 User manual Network Card 2
18 Sony AC-SQ950D User manual Network Card 0
19 Sony BBV RX100 User manual Network Card 3
20 Sony CLIE A-AVZ-100-11 User manual Network Card 1