ADTRAN 3000 NTU-8 user manual

User manual for the device ADTRAN 3000 NTU-8

Device: ADTRAN 3000 NTU-8
Category: Network Card
Manufacturer: ADTRAN
Size: 0.9 MB
Added : 4/5/2014
Number of pages: 18
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for ADTRAN 3000 NTU-8. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with ADTRAN 3000 NTU-8.

For your convenience

If looking through the ADTRAN 3000 NTU-8 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual ADTRAN 3000 NTU-8 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual ADTRAN 3000 NTU-8 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
ADTRAN 3000 NTU-8 User manual - Online PDF
Advertisement
« Page 1 of 18 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual ADTRAN 3000 NTU-8 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to ADTRAN 3000 NTU-8. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

®
Total Access 3000/3010
NTU-8 Single Fiber Quad E1
Installation and Maintenance Practice
Document Number: 61182301E1-5A
January 2008

Summary of the content on the page No. 2

Total Access 3000/3010 NTU-8 Single Fiber Quad E1 Installation and Maintenance Practice Front Matter Trademarks Any brand names and product names included in this document are trademarks, registered trademarks, or trade names of their respective holders. To the Holder of this Document ® The contents of this document are current as of the date of publication. ADTRAN reserves the right to change the contents without prior notice. In no event will ADTRAN be liable for any special, incidental, or

Summary of the content on the page No. 3

Revision History Revision Date Description A January 2008 Initial release Conventions The following typographical conventions are used in this document: This font indicates a cross-reference link. This font indicates screen menus, fields, and parameters. THIS FONT indicates keyboard keys (ENTER, ESC, ALT). Keys that are to be pressed simultaneously are shown with a plus sign (ALT+X indicates that the ALT key and X key should be pressed at the same time). This font indicates references to othe

Summary of the content on the page No. 4

Total Access 3000/3010 NTU-8 Single Fiber Quad E1 Installation and Maintenance Practice Training ADTRAN offers training courses on our products. These courses include overviews on product features and functions while covering applications of ADTRAN product lines. ADTRAN provides a variety of training options, including customized training and courses taught at our facilities or at customer sites. For inquiries concerning training, contact ADTRAN: Training Phone: 800-615-1176, ext. 6996 Train

Summary of the content on the page No. 5

Contents General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Summary of the content on the page No. 6

Total Access 3000/3010 NTU-8 Single Fiber Quad E1 Installation and Maintenance Practice Tables Table 1. Compliance Codes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Table 2. Front Panel LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Table 3. Rear Panel Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Summary of the content on the page No. 7

Total Access 3000/3010 NTU-8 Single Fiber Quad E1 GENERAL ® This document is an installation and maintenance guide for the Total Access 3000/3010 NTU-8 Single Fiber Quad E1 with Ethernet and Performance Monitoring (NTU-8F). Figure 1 illustrates the NTU-8F (P/N 1182301E1) front panel. Figure 1. NTU-8F Front Panel DESCRIPTION The NTU-8F is a standalone remote network terminal unit that provides for transport four, short-haul E1 (G.703) channels, and a 10Base-T or 100Base-T (10/100) Ethernet

Summary of the content on the page No. 8

Total Access 3000/3010 NTU-8 Single Fiber Quad E1 Installation and Maintenance Practice • Operation over extended temperature range of –5°C to +55°C • Optical interface consisting of a single mode transceiver module comprised of a single fiber transmitter and an SC connector • Optical interface port support for flat SC-type optical connectors • Single fiber optical interface • Operating wavelengths of 1310 nm and 1550 nm for both receiver and transmitter Compliance The NTU-8F is compliant with

Summary of the content on the page No. 9

Installation INSTALLATION C A U T I O N ! SUBJECT TO ELECTROSTATIC DAMAGE OR DECREASE IN RELIABILITY. HANDLING PRECAUTIONS REQUIRED. CAUTION Electrostatic Discharge (ESD) can damage electronic modules. When handling modules, wear an antistatic discharge wrist strap to prevent damage to electronic components. Place modules in antistatic packing material when transporting or storing. When working on modules, always place them on an approved antistatic mat that is electrically grounded. After unp

Summary of the content on the page No. 10

Total Access 3000/3010 NTU-8 Single Fiber Quad E1 Installation and Maintenance Practice Physical Installation To install the NTU-8F, perform the following steps: 1. Place the unit in a location where a DC power source is available. This unit operates within a voltage range of –24 VDC to –48 VDC. If a wall-mount installation is required, attach the supplied hangers to the unit. 2. Connect power to the NTU-8F housing. Power is connected to the NTU-8F by connecting the plus (+), minus (–), and g

Summary of the content on the page No. 11

Installation Table 2. Front Panel LEDs (Continued) Label Status Description LBK Off No loopback on selected channel Green Selected G.703 E1 port in local loopback Yellow Selected G.703 E1 port in remote loopback (PN127 or V.54) Red Selected G.703 E1 port in local or remote loopback (PN127 or V.54); when no port is selected, this becomes an OR’d summation of all loopbacks on all ports BERT Off Selected G.703 E1 port BERT not active Green Selected G.703 E1 port BER, with no errors Yellow

Summary of the content on the page No. 12

Total Access 3000/3010 NTU-8 Single Fiber Quad E1 Installation and Maintenance Practice PROVISIONING The NTU-8F is automatically configured to match the LTU-8 settings and does not require local provisioning. Provisioning for the LTU-8 is via the Total Access 3000/3010 System Controller Unit (SCU). The SCU initiates and controls the transfer of commands and data to and from the LTU-8. The LTU-8 generates all menu items for both the LTU-8 and the NTU-8F. The LTU-8 retains provisioning data in

Summary of the content on the page No. 13

Provisioning Table 4. Provisioning Defaults (Continued) NTU-8F Settings Defaults LT Clock Source Internal Clock; G.703 Rx Clock G.703 Rx Clock; Fiber Rx Clock NT Clock Source Internal Clock; Fiber Rx Clock G.703 Rx Clock; Fiber Rx Clock ISDN-PRA V3 Disabled; Disabled Enabled LTU Ethernet Service State In Service; Out of Service-Maintenance Out of Service-Maintenance; Out of Service-Unassigned NTU Ethernet Service State In Service; Out of Service-Maintenance Out of Service-Maintenance; Out o

Summary of the content on the page No. 14

Total Access 3000/3010 NTU-8 Single Fiber Quad E1 Installation and Maintenance Practice OPERATION The NTU-8F provides a platform to exchange data between four G.703 interfaces and an optical fiber interface. The customer data connection is via the RJ-45 connector on the unit. An optical fiber interface is provided for communication with the loop. The NTU-8F operates with an LTU-8 at the other end of the fiber optic cable. FRONT PANEL PUSHBUTTON Pushbuttons on the front panel (Table 5) provide

Summary of the content on the page No. 15

Specifications SPECIFICATIONS Specifications for the NTU-8F are detailed in Table 6. Table 6. NTU-8F Specifications Specification Description Environmental Operating Temperature: –5°C to +55°C Storage Temperature: –40°C to +85°C Relative Humidity: Up to 95% noncondensing Physical Dimensions: Height: 1.8 inches Width: 8.0 inches Depth: 9.0 inches Weight: 2.5 pound Power Input Voltage Range: –42 VDC to –56 VDC inputs Maximum Current Draw: 90 mA at –48 VDC Maximum Power Dissipation: 4.32 watts

Summary of the content on the page No. 16

Total Access 3000/3010 NTU-8 Single Fiber Quad E1 Installation and Maintenance Practice This page is intentionally blank. 10 61182301E1-5A

Summary of the content on the page No. 17

Appendix A Warranty WARRANTY AND CUSTOMER SERVICE ADTRAN will replace or repair this product within the warranty period if it does not meet its published specifications or fails while in service. Warranty information can be found at www.adtran.com/warranty. Refer to the following subsections for sales, support, Customer and Product Service (CAPS) requests, or further information. ADTRAN Sales Pricing/Availability: 800-827-0807 ADTRAN Technical Support Pre-Sales Applications/Post-Sales Tech

Summary of the content on the page No. 18

® Carrier Networks Division 901 Explorer Blvd. Huntsville, AL 35806


Alternative user manuals
# User manual Category Download
1 ADTRAN 1000 User manual Network Card 1
2 ADTRAN 1xN User manual Network Card 0
3 ADTRAN 1200051L5 User manual Network Card 0
4 ADTRAN 1204006L1 User manual Network Card 0
5 ADTRAN 1000R Series User manual Network Card 0
6 ADTRAN 1200051L2 User manual Network Card 0
7 ADTRAN 1204002L1 User manual Network Card 0
8 ADTRAN 220 DDM, 3192 H2TU-C User manual Network Card 0
9 ADTRAN 1355 PWR User manual Network Card 0
10 ADTRAN 3000 HTU-C User manual Network Card 0
11 ADTRAN 25 User manual Network Card 0
12 ADTRAN 3010 HTU-C User manual Network Card 0
13 ADTRAN 3192 H2TU-C User manual Network Card 3
14 ADTRAN 239 T1 HDSL4 User manual Network Card 0
15 ADTRAN 3010 User manual Network Card 0
16 Sony BTA-NW1A User manual Network Card 2
17 Sony BKMW-E3000 User manual Network Card 2
18 Sony AC-SQ950D User manual Network Card 0
19 Sony BBV RX100 User manual Network Card 3
20 Sony CLIE A-AVZ-100-11 User manual Network Card 1