GE P485 user manual

User manual for the device GE P485

Device: GE P485
Category: Network Card
Manufacturer: GE
Size: 2.22 MB
Added : 8/10/2014
Number of pages: 76
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for GE P485. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with GE P485.

For your convenience

If looking through the GE P485 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual GE P485 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual GE P485 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
GE P485 User manual - Online PDF
Advertisement
« Page 1 of 76 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual GE P485 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to GE P485. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

D
G
E
E
R
M
E
U
T
GE Consumer & Industrial
P485 Modbus to Profibus
Converter
Instruction Manual
Manual P/N: 1601-0237-A1
Manual Order Code: GEK-113190
Copyright © 2005 GE Multilin
ISO9001:2000
GE Multilin
215 Anderson Avenue, Markham, Ontario
Canada L6E 1B3 GE Multilin's Quality
Management System is
Tel: (905) 294-6222 Fax: (905) 201-2098 registered to ISO9001:2000
QMI # 005094
Internet: http://www.GEmultilin.com
UL # A3775
L
S
T
I
I
L
G
I
E
N
R

Summary of the content on the page No. 2

Summary of the content on the page No. 3

GE Consumer & Industrial P485 Modbus to Profibus Converter Table of contents INTRODUCTION Getting started........................................................................................................1–1 Inspecting the package and product.................................................................................................1–1 Contact information...................................................................................................................................1

Summary of the content on the page No. 4

TABLE OF CONTENTS Profibus installation procedure ...........................................................................2–7 Profibus configuration tool.....................................................................................................................2–7 Profibus network termination ...............................................................................................................2–7 Links .........................................................................

Summary of the content on the page No. 5

TABLE OF CONTENTS Basic settings ..........................................................................................................5–2 Parameter window .....................................................................................................................................5–2 Communication............................................................................................................................................5–2 Message delimiter.............................

Summary of the content on the page No. 6

TABLE OF CONTENTS Step 1: Selecting the fieldbus type......................................................................................................9–6 Step 2: Selecting the sub-network properties ...............................................................................9–7 Step 3: Include device types ..................................................................................................................9–7 Step 4: Connect devices to the sub-network........................

Summary of the content on the page No. 7

GE Consumer & Industrial P485 Modbus to Profibus Converter Chapter 1: Introduction Introduction Getting started INSPECTING THE Examine the shipping container for obvious damage prior to installing this product; notify PACKAGE AND PRODUCT the carrier of any damage that you believe occurred during shipment or delivery. Inspect the contents of this package for any signs of damage and ensure that the items listed below are included. Remove the items from the shipping container. Be sure to keep t

Summary of the content on the page No. 8

INTRODUCTION Document conventions DESCRIPTION The following conventions are used throughout this document: • Numbered lists provide sequential steps. • Bulleted lists provide information, not procedural steps. • The term ‘user’ refers to the person or persons responsible for installing the P485 Modbus to Profibus Converter in a network. • Hexadecimal values are written in the format 0xNNNN, where NNNN is the hexadecimal value. • Decimal values are represented as NNNN, where NNNN is the decimal

Summary of the content on the page No. 9

INTRODUCTION About the P485 Modbus to Profibus Converter APPLICATION The P485 Modbus to Profibus Converter (or P485) acts as a gateway between the Modbus protocol and a Profibus-DP network. Integration of industrial devices is enabled without loss of functionality, control, and reliability, both when retrofitting to existing equipment as well as when setting up new installations. Profibus master (PLC) Profibus master (PLC) HMI HMI Profibus slave Profibus slave PC for configuration and monitor

Summary of the content on the page No. 10

INTRODUCTION Ordering ORDER CODES The following table illustrates the order codes for the P485 Modbus to Profibus Converter. Table 1–1: P485 order codes P485 – * Base unit P485 | P485 Modbus to Profibus Converter C With configuration cable X No configuration cable Specifications MECHANICAL HOUSING Plastic housing with snap-on connection to DIN-rail, protection class IP20 DIMENSIONS L x W x H: 120 mm × 75 mm × 27 mm (4.72-in × 2.95-in × 1.06-in) PROTECTION CLASS Protection class: IP20 ELECTRICAL

Summary of the content on the page No. 11

GE Consumer & Industrial P485 Modbus to Profibus Converter Chapter 2: Installation Installation Quick install PROCEDURE 1. Snap the P485 on to the DIN-rail (see DIN-rail mounting on page 2–5). 2. Connect the Profibus cable (see Profibus connector on page 2–2). 3. Connect the serial Modbus network cable (see Modbus connector on page 2–4 for details). 4. Connect a PC using the configuration cable (see Configuration cable on page 2–3). 5. Connect the power cable and apply power to the unit (see P

Summary of the content on the page No. 12

INSTALLATION A B C E D Figure 2-1: P485 electrical connections PROFIBUS CONNECTOR The Profibus connector is indicated as A in the figure above. This connector is used to connect the P485 to the Profibus network. The pin assignments for the Profibus connector are shown below. Table 2–1: Profibus connector pin assignments Pin Signal Description 1- - 2- - 3 B-Line Positive RxD/TxD (RS485) 4 RTS * Request To Send 5 GNDBUS ** Isolated ground from the RS485 side 6 +5 V BUS ** Isolated +5V output from

Summary of the content on the page No. 13

INSTALLATION CONFIGURATION CABLE The PC connector is indicated as B in Figure 2-1: P485 electrical connections on page 2–2. This connector is used to connect the P485 to a PC using the configuration cable for configuration and monitoring purposes. A P485/D485 configuration cable can be purchased from GE Multilin. The wiring for the configuration cable is shown below. D-sub 9 female (PC) Modular 4/4 RJ11 connector (P485) 1 1 Ground RS232 Rx 2 2 Ground RS232 Tx 3 3 Rx 4 4 Tx Ground 5 Connects t

Summary of the content on the page No. 14

INSTALLATION 51 9 6 (female) Figure 2-5: Configuration cable (PC end) MODBUS CONNECTOR The Modbus connector is indicated as C in Figure 2-1: P485 electrical connections on page 2–2. This connector is used to connect the P485 to the serial network. Based on the configuration selected in the EnerVista P485/D485 Setup software, the corresponding signals are activated. 51 9 6 (female) Figure 2-6: Modbus connector Table 2–4: Modbus connector pin assignments Pin Description RS232 RS422 RS485 1 +5 V

Summary of the content on the page No. 15

INSTALLATION Mechanical installation DIN-RAIL MOUNTING The DIN-rail connector is internally connected to the P485. 1 1 ON OFF 2 2 Figure 2-8: Mounting the P485 to the DIN-rail To snap the P485 on, first press the P485 downwards (1) to compress the spring on the DIN- rail connector, then push the P485 against the DIN-rail as to make it snap on (2) To snap the P485 off, push the P485 downwards (1) and pull it out from the DIN-rail (2), as to make it snap off from the DIN-rail. Indicators and swit

Summary of the content on the page No. 16

INSTALLATION Table 2–5: P485 status indicators Number Description State Status 1 Profibus online Off Not online Green Online 2 Profibus offline Off Not offline Red Offline 3Not used - - 4Profibus Off No diagnostics present diagnostics Red, flashing 1 Hz Error in configuration Red, flashing 2 Hz Error in user parameter data Red, flashing 4 Hz Error in initialisation 5 Subnet status * Off Power off (Modbus) Green, flashing Initializing and not running Green Running Red Stopped or subnet error, or

Summary of the content on the page No. 17

INSTALLATION For example, to set the node address to 42, set switch A to “2” and switch B to “4”. When removing the hatch, avoid touching the circuit boards and components. Exercise caution when using tools to open the hatch. NOTE Profibus installation procedure PROFIBUS Each device on a Profibus-DP network is associated with a GSD file, which contains all necessary information about the device. This file is used by the Profibus configuration tool CONFIGURATION TOOL during configuration of th

Summary of the content on the page No. 18

INSTALLATION Troubleshooting DESCRIPTION Problem during configuration upload/download. The Config Line LED turns red. • Serial communication failed – try again. The serial port seems to be available, but it is not possible to connect to the P485. • The serial port may be in use by another application. Exit EnerVista P485/D485 Setup and close all other applications including the ones in the system tray and try again. • Select another serial port and try again. Poor performance. • Right click ‘Mo

Summary of the content on the page No. 19

General data GE Consumer & Industrial P485 Modbus to Profibus Converter Chapter 3: Data exchange Data exchange Overview DESCRIPTION Data from the fieldbus (Profibus) and the sub network (Modbus) is stored in an internal memory buffer. This is a easy method for data exchange where the fieldbus control system simply reads and writes data to pre-defined memory locations, and the serial sub network also use the same internal memory buffer to read and write data. Refer to Figure 3-2: Data exchan

Summary of the content on the page No. 20

DATA EXCHANGE PLC memory I/O inputs I/O outputs Current Ia CT PRIMARY The PLC exchanges data The PLC exchanges data via the Profibus network via the Profibus network between its internal input between its internal output area and the input area area and the output area of the P485 of the P485 Profibus network Internal memory buffer of the P485 Input data area Output data area General data area 0x0000 0x0200 0x0400 Current Ia CT PRIMARY The data in the input area of The data in the output area of


Alternative user manuals
# User manual Category Download
1 GE 1019071 User manual Network Card 4
2 GE DEH-210 User manual Network Card 0
3 GE EPM5200P User manual Network Card 6
4 GE DIGITAL ENERGY 1018959 User manual Network Card 13
5 GE EPM 7300 User manual Network Card 13
6 GE 23954 User manual Network Card 2
7 GE EPM9650Q User manual Network Card 2
8 GE EPM 7700 User manual Network Card 2
9 GE GFK-1541B User manual Network Card 41
10 GE FPC 1000 User manual Network Card 6
11 GE H6505A User manual Network Card 0
12 GE EPM9450Q User manual Network Card 3
13 GE GFK-1852 User manual Network Card 4
14 GE H-6513 User manual Network Card 0
15 GE JGBP30BEH User manual Network Card 0
16 Sony BTA-NW1A User manual Network Card 2
17 Sony BKMW-E3000 User manual Network Card 2
18 Sony AC-SQ950D User manual Network Card 0
19 Sony BBV RX100 User manual Network Card 3
20 Sony CLIE A-AVZ-100-11 User manual Network Card 1