Icom DSC CONTROLLER DS-100 user manual

User manual for the device Icom DSC CONTROLLER DS-100

Device: Icom DSC CONTROLLER DS-100
Category: Network Card
Manufacturer: Icom
Size: 0.27 MB
Added : 8/8/2014
Number of pages: 36
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Icom DSC CONTROLLER DS-100. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Icom DSC CONTROLLER DS-100.

For your convenience

If looking through the Icom DSC CONTROLLER DS-100 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Icom DSC CONTROLLER DS-100 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Icom DSC CONTROLLER DS-100 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Icom DSC CONTROLLER DS-100 User manual - Online PDF
Advertisement
« Page 1 of 36 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Icom DSC CONTROLLER DS-100 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Icom DSC CONTROLLER DS-100. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

INSTRUCTION MANUAL
DSC CONTROLLER
DS-100

Summary of the content on the page No. 2

FOREWORD FEATURES Thank you for purchasing this Icom product. The DS-100 DSC Class D DSC terminal CONTROLLER is designed and built with Icom’s superior tech- The DS-100 VHF DSC CONTROLLER is designed as a nology and craftsmanship. With proper care this product should ‘Class D DSC terminal unit’ for the IC-M501EURO VHF provide you with years of trouble-free operation. MARINE TRANSCEIVER. Self ID indication The DS-100 does not function when there is no ID is pro- IMPORTANT grammed. Therefore,

Summary of the content on the page No. 3

CAUTIONS DO NOT operate the controller without running the ves- RWARNING! NEVER connect the controller to an AC sel’s engine. When your vessel’s engine is OFF and the con- outlet. This may pose a fire hazard or result in an electric troller is transmitting, the vessel’s battery will soon become shock. exhausted. RWARNING NEVER transmit a distress call when DO NOT use chemical agents such as benzene or alcohol your vessel does not need immediate help. Distress calls can when cleaning, as they can

Summary of the content on the page No. 4

TABLE OF CONTENTS FOREWORD ........................................................................ i Address ID ................................................................. 17 IMPORTANT ........................................................................ i Offset time ................................................................. 19 EXPLICIT DEFINITIONS ...................................................... i Brightness .........................................................

Summary of the content on the page No. 5

PANEL DESCRIPTION 1 ➥ Push this key to call subject menu screen. ➥ Push the key to return the start screen. r ENTER [ENT] u ➥ Enters the selected subject and advances the item to in- DSC CONTROLLER ds-100 dicate the contents. ➥ Push this key to determine the data. 1 2 3 QZ ABC DEF t UP/DOWN/LEFT/RIGHT SWITCHES [Y]/[Z]/[ΩΩ ]/[≈ ≈] 4 5 6 GHI JKL MNO ➥ Push [Y]/[Z] to select the menu contents in the selected y 7 8 9 PRS TUV WXY item. 0 BS ➥ Push [Y]/[Z] to adjust brightness and contrast. WATER RE

Summary of the content on the page No. 6

1 PANEL DESCRIPTION must be set in advance. NOTE: If GPS data is interrupted for 30 sec. the “GPS” indi- cation disappears. The terminal unit retains the most recent data in such cases. Function display q GPS INDICATOR ➥ “GPS” appears while GPS receiver is connected. -VHF DSC CONTROLLER- ➥ “GPS’ disappears when no GPS receiver is connected. ➥ “MNL’ appears when the time data and position data are CH 70 WATCHING input manually. w TIME ZONE INDICATOR ➥ “Local” appears when the offset time da

Summary of the content on the page No. 7

CALL PROCEDURE 2 e After transmitting the call, the transceiver is set to the Distress call/Simple operation phone frequency (ch 16) au- tomatically. A distress call should be transmitted if, in the opnion of the Distress alert • The controller is still waiting on Master, the ship or a person is in distress and requires imme- Completed ch 70 for an acknowledgment diate assistance. Now waiting for call. A distress call should include the ship’s position and time. acknowledgemnt r When receivin

Summary of the content on the page No. 8

2 CALL PROCEDURE t Lift up the [DISTRESS] switch cover, pushing and holding Distress call/Regular operation the button for 5 sec. to trans- mit the distress call. Transmit a distress call after selecting the ‘Distress setting’. several times to select ‘Indi- ≈Manual e

Summary of the content on the page No. 11

2 CALL PROCEDURE Group call All ships call q Push [CALL], then push [√] q Push [CALL], then push [√] one or more times to select one or more times to select ‘Group call’, then push ‘All ships call’, then push ≈Manual entry Safety [ENT]. [ENT]. ICOM ≈Urgency w Select the desired address, w Select the desired category, then push [ENT]. then push [ENT]. • Enter the 8 digit address when e Push [CALL] and [ENT] si- ‘Manual e

Summary of the content on the page No. 12

2 CALL PROCEDURE D When no acknowledgement is received D After receiving acknowledgement call If no acknowledgement is received, the emergency alarm will The following should be commenced with your voice trans- sound continuously. In this case, the controller automatically mission after receiving a distress acknowledgement from a tramsmits the distress call again every 3.5 to 4.5 minutes. coast station (or another ship). • Push [CLR] if you want to stop the alarm. • “MAY DAY” • A distress relay

Summary of the content on the page No. 13

WHEN RECEIVING A CALL 3 • Monitoring the traffic frequency To receive a DSC call The calling station transmits via voice on the traffic frequency. D When receiving a DSC call —RCV All ships call— • Emergency alarm (or con- You should act in one of the following ways depending on the tinuous beeps depending From: ICOM DSC received DSC format (or category): on the category) sounds Category:Routine until pushing [CLR]. • Wait for a voice transmission on the traffic frequency. • Transmit an acknowled

Summary of the content on the page No. 14

3 WHEN RECEIVING A CALL D When receiving an individual call When receive a Distress call When receiving an individual call, an alarm (Pi-pi) sounds. —RCV Individual call— D When receiving a Distress call • Push [ENT], then the oper- When receiving a distress call, ating channel changes to From: JHON an alarm (Pi-po) sounds with —RCV Distress call— designated channel. max. AF level continuously. And • Push [CLR] to record the Distress ID: at the same time, the trans- received information, then

Summary of the content on the page No. 15

3 WHEN RECEIVE A CALL D When receiving an All ships call D When receiving a Position request When receiving a Routine or When receiving a Position re- Safety all ships call, an alarm quest call, an alarm (Pi-pi) —RCV All ships call— —RCV Pos request— (Pi-pi) sounds. sounds. When you receive a distress or • Push [ENT] to transmit your From: 23456789 From: JHON Category:Routine Urgency all ships call, an alarm own ships longitude and lat- (Pi-po) sounds with max. AF itude information. To reply, pu

Summary of the content on the page No. 16

3 WHEN RECEIVING A CALL D When receiving a Distress ACK D When receiving a group call When receiving a distress ac- When receiving a Group call, knowledgement, an alarm (Pi- an alarm (Pi-pi) sounds. —RCV Group call— —RCV Distress ACK— po) sounds with max. AF level • Push [ENT], then the oper- continuously. And at the same ating channel changes to From: DS-100 SN3 From: Tokyo guard time, the transceiver’s (IC- designated channel. Group:Icom Inc Distress ID: Mr.Bean M501EURO) operating channel • P

Summary of the content on the page No. 17

3 WHEN RECEIVING A CALL D Distress message Received message (RCV MSG) When receiving a DSC call, the received format specifier and q Push [CALL], then push [√]