Kathrein BN 20610071 user manual

User manual for the device Kathrein BN 20610071

Device: Kathrein BN 20610071
Category: Network Card
Manufacturer: Kathrein
Size: 1.39 MB
Added : 2/18/2014
Number of pages: 24
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Kathrein BN 20610071. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Kathrein BN 20610071.

For your convenience

If looking through the Kathrein BN 20610071 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Kathrein BN 20610071 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Kathrein BN 20610071 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Kathrein BN 20610071 User manual - Online PDF
Advertisement
« Page 1 of 24 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Kathrein BN 20610071 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Kathrein BN 20610071. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

User manual
UFX 314 data bus de-multiplexer
(BN 20610071)

Summary of the content on the page No. 2

Contents Page General 3 3 1. Features 2. Mechanical layout 4 2.1 Rear view 4 2.2 Front view 4 2.3 Status LEDs 4 3. Installation 3.1 Installation 5 ® 3.2 UFO compact controller 7 3.3 Network confi guration 7 3.4 USB installation 8 3.4.1 Microsoft Windows 8 3.4.2 Linux 11 11 4. Software Update 5. Web interface 5.1 The main page 12 5.1.1 The device group box 12 5.1.2 The system group box 12 5.2 Log page 12 5.3 Status page 13 5.4 Update page 13 6. Modem access 6.1 Setting up in Microsoft Windows 13 6

Summary of the content on the page No. 3

General The UFX 314 data bus de-multiplexer (BN 20610071) is used for the central control of all channel units installed in a UFG 412 base unit. Each channel unit is connected using a separate cable. Several demultiplexers can be con- nected to a system over a network. 1. Features Facilitates the use of the USW 30 control software Required on the use of certain functions for some channel units, e. g. for NIT generation ® Can be used to update older UFO compact systems ® Control of individua

Summary of the content on the page No. 4

2. Mechanical layout The points are described in the plan view from left to right. 2.1 Rear view Redundant Power System Expansion connection for monitoring a redundant power supply, currently has no function Modem USB port for connecting a modem (see section 6) or a USB stick Power Power connection 12.5 V/approx. 200 mA (without controller or USB device), max. 900 mA ® 12 x Mini-DIN sockets For the connection of up to 12 UFO compact channel units 2.2 Front view 12 x port LEDs These LEDs are us

Summary of the content on the page No. 5

3. Installation 3.1 Installation The demultiplexer is installed in the 1 HU fan unit that is mounted above the base unit. For this purpose the following steps are required: Fit the UFX 314 into the 19” front panel (1 HU) supplied Remove the pre-assembled blanking plate Connect straight connectors on connecting cables to the demultiplexer (mini-DIN sockets 1 ... 12) The angled version is to be connected to the modules If a modem is being used, an RS 232 adapter must be connected (special acce

Summary of the content on the page No. 6

44 ( =1HE) 355 ( =8HE) 6 Channel unit 1 Kanal zug 1 Channel unit 12 Kanal zug 12 483 Channel unit 1 Channel unit 12 Kanal zug 1 Kanal zug 12

Summary of the content on the page No. 7

Connect the power cable for the UFX 314 to the screw terminals in the power supply for the base unit ® 3.2 UFO compact controller ® The UFO compact controller can be connected to any of the demultiplexers. However, it is to be noted that the controller only operates with the demultiplexers that belong to the same group to which it is connected. The usage ® of an older UFO compact controller prior to software version 9.20 is in principle possible, however there may be connection problems wit

Summary of the content on the page No. 8

3.4 USB installation 3.4.1 Microsoft Windows You will fi nd the driver for the connection of a PC using USB on the USW 30 control software CD (not included). To install the driver, you will need administrator permissions on the PC. The installation is described based on the English version of Windows XP. If the UFX 314 indicates an error after connecting/changing connections, or if it is not correctly detected by Windows, disconnect it from the PC and restart it using the Reset button. Before

Summary of the content on the page No. 9

Ignore this message by clicking “Continue Anyway”. The driver is now installed. Note: After driver installation has been completed, a new network connection will be available (name “USB Ethernet/RNDIS”) which can be confi gured and used as a standard (Ethernet) network connection. The driver installation is now complete. Windows confi rms again that the driver has been installed. If this message does not appear or if you have selected “Zeroconf” (factory setting) as the address for UFX

Summary of the content on the page No. 10

Click “Properties”. Select “Internet Protocol (TCP/IP)” and then click “Properties”. 10

Summary of the content on the page No. 11

Select “Use the following IP address”. You must complete “IP address” and “Subnet mask” to suit the address of your demultiplexer. If the UFX 314 is operated with DHCP, ask the person responsible for the DHCP server for the correct settings - in most cases “Obtain an IP address automatically” works. If “Zeroconf” (factory setting) is used on the UFX 314, select “Obtain an IP address automatically”. If the UFX 314 is set to “Manual”, you must set an IP and subnet mask suitable for the devi

Summary of the content on the page No. 12

5. Web interface Every UFX 314 has a web interface that can be reached by entering the IP address for the demultiplexer in a web browser. You can determine the address using USW 30 or KUBdate. 5.1 The main page The main page is divided into two areas, at the top the serial number, IP address and other links for the demultiplexer and below a list of all demultiplexers found, sorted by groups. All the links for a demultiplexer can be password-protected. The password is the same as for the PPP a

Summary of the content on the page No. 13

5.3 Status page The Status page contains information on network addresses, software and hardware versions as well as the time and capacity utilisation. 5.4 Update page On this page you can update the device's software. Normally the software is updated using the application KUBdate. You can extract the update archive from the Kathrein update bundle using a ZIP application; then upload it using this page. Should the bundle contain several archives, the fi le "bundle_info.xml" will provide infor

Summary of the content on the page No. 14

Select here “Connect to the Internet” and then click “Next”. Now select “Set up my connection manually”. After selecting “Connect using a dial-up modem”, use “Next” to open the dialog box for the connection's name. 14

Summary of the content on the page No. 15

Enter a meaningful name for the connection to this demultiplexer as the name for the Internet service provider. Enter here the telephone number to which the demultiplexer is connected. Enter here the same user name and password as you have set using USW 30. A check mark must also be set at “Make this the default Internet connection”. If you have not entered a password using USW 30, or have entered a blank password, the UFX 314 will accept any login, irrespective of user name and passwor

Summary of the content on the page No. 16

The “New Connection Wizard” is completed with this dialog box. If you want, you can select “Add a shortcut to this connection to my desktop” to be able to make the connection in future directly from the desktop. Otherwise, you will fi nd the connection in the network connections where you have just opened the wizard. This window always appears when you want to establish a connection with the UFX 314. The fi rst time this window is opened, it is necessary to make a few further settings. For t

Summary of the content on the page No. 17

If you are using an ISDN modem, click “Confi gure”. Otherwise select the “Security” tab. With an ISDN modem you must change the “Modem protocol” setting to “V.120 (64k)”. After accepting your changes using “OK”, select the “Security” tab. 17

Summary of the content on the page No. 18

If “Show terminal window” or “Run script” is selected, clear the selection. Click “Advanced” and then click “Settings” to change the advanced security settings. In this dialog box, select as “Data encryption” “No encryption allowed” and then “Allow these protocols”. Only “Unencrypted password” is to be selected. After leaving this dialog box using “OK”, also leave the “Properties” dialog box using “OK”. 18

Summary of the content on the page No. 19

Now click “Dial” to establish the connection. The settings made are saved and do not need to be made again next time. 6.2 Setting up in Linux It is recommended to use a terminal program with a graphic interface such as KPPP. It should be noted that all modems currently available with a USB interface have been primarily developed for Windows and they may therefore be diffi cult or impossible to use with Linux. It is signifi cantly easier to use serial modems, if necessary also with USB-RS 232

Summary of the content on the page No. 20

Select the “Accounts” tab and click “New ...”. Select “Manual Setup” at the prompt. Enter a meaningful name for your connection in the “Connection name” box. Click “Add ...” to open a dialog box for entering the demultiplexer's telephone number. On the other tabs you can leave all the default settings. The default settings should be as follows: IP Dynamic IP address Gateway Standard gateway and standard route on this gateway DNS Automatically Login Script Blank Execute Blank Invoici


Alternative user manuals
# User manual Category Download
1 Kathrein UFO 20610040 User manual Network Card 1
2 Kathrein UFO UFX 312 User manual Network Card 6
3 Kathrein UFX 314 User manual Network Card 6
4 Sony BTA-NW1A User manual Network Card 2
5 Sony BKMW-E3000 User manual Network Card 2
6 Sony AC-SQ950D User manual Network Card 0
7 Sony BBV RX100 User manual Network Card 3
8 Sony CLIE A-AVZ-100-11 User manual Network Card 1
9 Sony BTA-NW1 User manual Network Card 11
10 Sony AC-NWUM50 User manual Network Card 1
11 Sony AR-B1474 User manual Network Card 2
12 Sony BKM-FW32 User manual Network Card 1
13 Sony 4000CL-MAV-PBIO User manual Network Card 1
14 Sony FA-ST1AM User manual Network Card 0
15 Sony MVC-FDR3/FDR3E User manual Network Card 1