National Instruments FP-1000 user manual

User manual for the device National Instruments FP-1000

Device: National Instruments FP-1000
Category: Network Card
Manufacturer: National Instruments
Size: 0.51 MB
Added : 10/30/2014
Number of pages: 50
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for National Instruments FP-1000. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with National Instruments FP-1000.

For your convenience

If looking through the National Instruments FP-1000 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual National Instruments FP-1000 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual National Instruments FP-1000 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
National Instruments FP-1000 User manual - Online PDF
Advertisement
« Page 1 of 50 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual National Instruments FP-1000 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to National Instruments FP-1000. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

Summary of the content on the page No. 2

Internet Support support@natinst.com E-mail: info@natinst.com FTP Site: ftp.natinst.com Web Address: http://www.natinst.com Bulletin Board Support BBS United States: (512) 794-5422 BBS United Kingdom: 01635 551422 BBS France: 01 48 65 15 59 Fax-on-Demand Support (512) 418-1111 Telephone Support (U.S.) Tel: (512) 795-8248 Fax: (512) 794-5678 International Offices Australia 03 9879 5166, Austria 0662 45 79 90 0, Belgium 02 757 00 20, Canada (Ontario) 905 785 0085, Canada (Québec) 514 694 8521, De

Summary of the content on the page No. 3

Important Information Warranty The FieldPoint modules are warranted against defects in materials and workmanship for a period of one year from the date of shipment, as evidenced by receipts or other documentation. National Instruments will, at its option, repair or replace equipment that proves to be defective during the warranty period. This warranty includes parts and labor. The media on which you receive National Instruments software are warranted not to fail to execute programming

Summary of the content on the page No. 4

Table of Contents About This Manual How to Use This Manual Set........................................................................................ix Organization of This Manual........................................................................................x Conventions Used in This Manual................................................................................x Related Documentation................................................................................................

Summary of the content on the page No. 5

Table of Contents SnapShot Feature.......................................................................................................... 3-2 Programmable Power-Up State .................................................................................... 3-3 HotPnP (Hot Plug and Play)......................................................................................... 3-4 HotPnP During Power-Up ............................................................................. 3-4 HotPnP During

Summary of the content on the page No. 6

Table of Contents Figure 2-8. RS-485 Connector Pinout for the FP-1000 and FP-1001 ......................2-7 Figure 2-9. Terminating RS-485 Using the Combicon Adapter ..............................2-8 Figure 2-10. Typical Signal Connections for Host Computer Connected to One FP-1000 and Multiple FP-1001 Network Modules........................2-8 Figure 2-11. Typical Signal Connections for Host Computer Connected to Multiple FP-1001 Network Modules................................................

Summary of the content on the page No. 7

About This Manual This manual describes how to install and use the FieldPoint FP-1000 and FP-1001 network modules. How to Use This Manual Set Operating Instructions for Modules and Bases FieldPoint Server Installation Online Help Specifications FieldPoint Programmer FieldPoint Network Connection, Reference User Manual Hardware Manual Configuration, and Feature Set Description Command Syntax © National Instruments Corporation ix FieldPoint FP-1000/FP-1001 User Manual

Summary of the content on the page No. 8

About This Manual Organization of This Manual This manual is organized as follows: • Chapter 1, FP-1000 and FP-1001 Network Module Overview, provides an overview of the FieldPoint network modules. • Chapter 2, Installation and Configuration, describes how to install and configure your FieldPoint network module, connect it to an RS-232 or RS-485 network, and connect power to the network module. • Chapter 3, Feature Set Description, describes the feature set for the FP-1000 and FP-1001 networ

Summary of the content on the page No. 9

About This Manual italic Italic text denotes emphasis, a cross reference, or an introduction to a key concept. This font also denotes text from which you supply the appropriate word or value, as in Windows 3.x. italic monospace Italic text in this font denotes that you must supply the appropriate words or values in the place of these items. monospace Text in this font denotes text or characters that should literally enter from the keyboard, sections of code, programming examples, and syntax

Summary of the content on the page No. 10

Chapter FP-1000 and FP-1001 1 Network Module Overview This chapter provides an overview of the FieldPoint network modules. The FP-1000 FieldPoint network module connects an industrial RS-232 network to FieldPoint I/O modules. The FP-1001 FieldPoint network module connects an industrial RS-485 network to FieldPoint I/O modules. The FP-1000 and FP-1001 support standard commands (subset of Optomux command set), and a set of extended commands to completely support the FieldPoint I/O modules.

Summary of the content on the page No. 11

Chapter 1 FP-1000 and FP-1001 Network Module Overview FP-1001 Connects to RS-485 The FP-1001 FieldPoint network module connects directly to an RS-485 adapter card that is installed in your host computer. Since RS-485 is inherently a multidrop network, the FP-1001 does not provide a separate RS-485 repeater. You can network multiple FP-1001 modules in multidrop fashion. The FP-1001 communicates over RS-485, utilizing full-duplex mode. It is optically isolated, which prevents fault coupling b

Summary of the content on the page No. 12

Chapter Installation and 2 Configuration This chapter describes how to install and configure your FieldPoint network module, connect it to an RS-232 or RS-485 network, and connect power to the network module. Installing the Network Module The FieldPoint network modules have rugged, simple clips for mounting reliably onto a standard 35 mm DIN rail. Follow these steps to mount the network module onto a DIN rail. Terminal bases must be connected to the network module before power is applied.

Summary of the content on the page No. 13

Chapter 2 Installation and Configuration 3. Slide the network module to the desired position on the DIN rail. After the module is in position, push the rail snap into the locked position to lock the module in place on the DIN rail, as shown in Figure 2-3. Network Module DIN Rail Snap Unlocked Rail Snap Rail (Position Module Along DIN Rail) Locked Figure 2-3. Locking the FieldPoint Network Module onto a DIN Rail Removing the Network Module To remove a network module, unlock it from the DIN ra

Summary of the content on the page No. 14

Chapter 2 Installation and Configuration 3. Attach the terminal base to the network module by firmly mating the local bus connectors. 4. To add more terminal bases, install them on the rail and mate their local bus connectors together. 5. Place the protective cover that you removed from the network module on the last terminal base on the bank, as shown in Figure 2-4. Local Bus Connectors Firmly Mated Protective Cover Rail Snap DIN Locked Rail Figure 2-4. Connecting Terminal Bases Connecti

Summary of the content on the page No. 15

Chapter 2 Installation and Configuration Host Computer FP-1001 FP-1001 FP-1000 RS-485 RS-232 Figure 2-5. Host Computer Connected to One FP-1000 and Two FP-1001 Network Modules Connecting the FP-1001 to the Network This section describes the network configurations possible with the FP-1001 FieldPoint network module. The connector pinouts are described in the RS-485 Interface Specifications section later in this chapter. One option for connecting the FP-1001 is to connect it to the RS-485 re

Summary of the content on the page No. 16

Chapter 2 Installation and Configuration Host Computer with RS-485 Board Installed FP-1001 FP-1001 FP-1001 RS-485 Figure 2-6. Host Computer Connected to Three FP-1001 Network Modules The multidrop topology used in the networking configurations provides protection against power failures at individual FieldPoint banks. It eliminates the possibility that a power failure at one FP-1001 bank might affect the communication between other banks in your network. Because the FP-1000 provides an RS-48

Summary of the content on the page No. 17

Chapter 2 Installation and Configuration Both serial interfaces are self-configured to use the following parameters: 1 Start Bit, 8 Data Bits, 1 Stop Bit, No Parity The supported baud rates are 300, 1200, 2400, 9600, 19200, 38400, 57600, and 115200. Refer to the Configuring the Network Module section for information about setting the baud rate for your modules. Host computer RS-232 ports and RS-485 interface boards provide FIFO buffers for transmit and receive that help to decrease the over

Summary of the content on the page No. 18

Chapter 2 Installation and Configuration The FP-1000 does not use RS-232 hardware handshaking, but it still asserts the RTS and DSR signals for host computers or software that may require these signals. A host computer that does not use these signals does not need to connect to them. RS-485 Interface Specifications RS-485 specifies a maximum cabling distance of 4000 ft, but improvements in line drivers and cabling technology often allow you to design your network beyond the recommendations

Summary of the content on the page No. 19

Chapter 2 Installation and Configuration + + RS-485 RS-485 – – Signal Pair Signal Pair 120 Ω 120 Ω Figure 2-9. Terminating RS-485 Using the Combicon Adapter An RS-485 network also needs biasing resistors to protect the devices on the network against noise during intervals when no RS-485 drivers are transmitting on the network. The host computer’s RS-485 interface normally has provision for such biasing resistors. When you are using FP-1001 network modules directly connected to a host comput

Summary of the content on the page No. 20

Chapter 2 Installation and Configuration FP-1001 FP-1001 FP-1001 + RX TX RX TX RX TX To Host Computer's RS-485 120Ω 120Ω – Receive Input Pair (RX) – From Host Computer's RS-485 120Ω 120Ω + Transmit Output Pair (TX) Connect the TX outputs of the host computer to the RX inputs of the FP-1001, and the RX inputs of the host computer to the TX outputs of the FP-1001. Figure 2-11. Typical Signal Connections for Host Computer Connected to Multiple FP-1001 Network Modules Configuring the Network Modul


Alternative user manuals
# User manual Category Download
1 National Instruments 24-Bit Half/Full-Bridge Analog Input Module NI 9237 User manual Network Card 11
2 National Instruments 700 User manual Network Card 2
3 National Instruments 370620B-01 User manual Network Card 0
4 National Instruments 5411 User manual Network Card 0
5 National Instruments 6508 PCI-DIO-96 User manual Network Card 1
6 National Instruments 8-Channel Solid-State Relay (SSR) Digital Output NI 9485 User manual Network Card 6
7 National Instruments 8330 Series User manual Network Card 0
8 National Instruments AT E Series User manual Network Card 4
9 National Instruments BNC-2140 User manual Network Card 0
10 National Instruments 374318A-01 User manual Network Card 0
11 National Instruments Cabled PCI Express User manual Network Card 0
12 National Instruments AutoCode NI MATRIX User manual Network Card 1
13 National Instruments cFP-20xx User manual Network Card 0
14 National Instruments DAQCard-1200 User manual Network Card 6
15 National Instruments Data Acquisition Device NI USB-621x User manual Network Card 10
16 Sony BTA-NW1A User manual Network Card 2
17 Sony BKMW-E3000 User manual Network Card 2
18 Sony AC-SQ950D User manual Network Card 0
19 Sony BBV RX100 User manual Network Card 3
20 Sony CLIE A-AVZ-100-11 User manual Network Card 1