Slant/Fin VHS-180 user manual

User manual for the device Slant/Fin VHS-180

Device: Slant/Fin VHS-180
Category: Boiler
Manufacturer: Slant/Fin
Size: 1.03 MB
Added : 3/24/2014
Number of pages: 27
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Slant/Fin VHS-180. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Slant/Fin VHS-180.

For your convenience

If looking through the Slant/Fin VHS-180 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Slant/Fin VHS-180 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Slant/Fin VHS-180 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Slant/Fin VHS-180 User manual - Online PDF
Advertisement
« Page 1 of 27 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Slant/Fin VHS-180 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Slant/Fin VHS-180. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

®
This manual must be left with owner and

should be hung on or adjacent to the boiler
for reference.
VICTORY II
HOT WATER MODELS VHS-30 THROUGH VHS-180
GAS-FIRED CAST-IRON BOILERS FOR NATURAL AND L.P. PROPANE GASES
Models with Intermittent Pilot System – Spark Ignition
INSTALLATION AND OPERATING INSTRUCTIONS
Contents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Page
IMPORTANT
Dimensions, Rating and Orifice Sizes . . . . . . . . . . . . . . . . . . .2
Installation

Summary of the content on the page No. 2

VICTORY II VHS Models Figure 1. Views - Dimensions - Data LEFT END VIEW FRONT VIEW RIGHT END VIEW 3 1 NOTE: Height dimensions increase by 1 ⁄4" and depth increases to 22 ⁄4" when combustible floor kit is used. Figure 2. Base Assembly Victory II - VHS Boiler Approx. Total Wt. Input Boiler No. of Full of Model Btuh Sections AB Water (lb.) 1 5 VHS-30 30,000 2 8 ⁄8"14 ⁄8" 190 Burners 1 5 VHS-60 60,000 3 11 ⁄8" 17 ⁄8" 250 1 5 Pilot VHS-90 90,000 4 14 ⁄8"20 ⁄8" 310 1 5 VHS-120 120,000 5 17 ⁄8"23 ⁄8" 3

Summary of the content on the page No. 3

VICTORY II VHS Models INSTALLATION REQUIREMENTS MINIMUM CLEARANCES FROM COMBUSTIBLE The installation must conform to the requirements of the CONSTRUCTIONS authority having jurisdiction or, in the absence of such requirements, to the National Fuel Gas Code, ANSI Z223.1- A. Minimum clearances to the exterior surfaces of the boiler latest edition. shall be as follows: MINIMUM ALCOVE AND CLOSET CLEARANCE This installation must also conform to the additional require- For Combustible Recommended ment

Summary of the content on the page No. 4

VICTORY II VHS Models BOILER ROOM AIR SUPPLY AND VENTILATION FLUE GAS VENTING REQUIREMENTS An ample supply of air is required for combustion and venti- The Victory II series boiler is a high efficiency, mechanically lation. When buildings are insulated, caulked and weather- induced draft boiler and, therefore, requires different venting stripped, now or later on, direct openings to outside may be arrangements than natural draft, lower efficiency boilers. required and should be provided. If the b

Summary of the content on the page No. 5

VICTORY II VHS Models 2. Flue Length Restriction Maximum and minimum equivalent flue length for different systems are given in the tables on page 6. Equivalent flue length is sum of straight flue lengths and equivalent length of elbows. The vent termination is in addition to the allowed equivalent lengths. Example: Boiler Model VHS-180 is to be installed at sea level with 2 elbows using Heat-Fab vent system. Maximum straight run would be: 40 - 2 x 3 = 34ft. If same boiler is to be installed in

Summary of the content on the page No. 6

VICTORY II VHS Models Heat-Fab Saf-T Vent System Max. Equivalent Length (Ft.) Equivalent 0 to 5500 to 7000 to Length of Boiler 5500 Ft. 7000 Ft. 10,000 Ft. each 90° Minimum Model No. Altitudes Altitudes Altitudes Elbow, Ft. Length, Ft. VHS-30, 40 40 40 3 2 60, 90 and 120 VHS-150 40 40 20 3 2 VHS-180 40 20 20 3 2 ProTech FasNSeal System Max. Equivalent Length (Ft.) Equivalent 0 to 5500 to 7000 to Length of Boiler 5500 Ft. 7000 Ft. 10,000 Ft. each 90° Minimum Model No. Altitudes Altitudes Altitude

Summary of the content on the page No. 7

VICTORY II VHS Models VICTORY II HORIZONTAL (SIDEWALL) VENTING All joints must be liquid and pressure tight. Use U/L listed single wall 3" dia. AL29-4C* S.S. venting materials * Definition of Snow Line: Knowledge of local conditions will reveal the maximum height that repeated Figure 5 snowfalls accumulate to. The height should be used as the SNOW LINE. * Definition of Snow Line: Knowledge of local conditions will reveal the maximum height that repeated Figure 6 snowfalls accumulate to. The he

Summary of the content on the page No. 8

VICTORY II VHS Models Figure 7. 8

Summary of the content on the page No. 9

VICTORY II VHS Models Figure 8. 9

Summary of the content on the page No. 10

VICTORY II VHS Models CATEGORY I VENTING (Natural Draft Chimney and Type “B” Venting) 1. Installation Model VHS-90, VHS-120, VHS-150 and VHS-180 may be vented into a natural draft masonry chimney or natural draft type“B” vent if a 3" diameter stainless steel elbow connected to the boiler’s flue collar and the vent connec- tor converted to 5" diameter using a 3" x 5" vent adapter. Single or multiple appliance venting are shown in Figures 9 and 10. 2. Vent Connector Material Vent connectors may be

Summary of the content on the page No. 11

VICTORY II VHS Models Natural Draft Chimney and Type “B”Venting Tables Table 1. Masonry Vitreous Tile-Lined Chimney (not metal lined) Chimneys not exposed to the outdoors below the roof line. (5" dia. vent adapter must be used) Additional National Fuel Gas Code Boiler Gas Appliance Reference Table No.* Model(s) † in Venting System Connector Requirements* (ANSI Z223.1) VHS-90 No Type “B” 1. Connector diameter must be upsized to 7". VHS-120 2. Chimney height limits: Min. 15 ft., Max. 30 ft. VHS-15

Summary of the content on the page No. 12

VICTORY II VHS Models Figure 9. 12

Summary of the content on the page No. 13

VICTORY II VHS Models Figure 10. 13

Summary of the content on the page No. 14

VICTORY II VHS Models VENTING SYSTEM REGULAR INSPECTION Gas Flow In piping -- cu. ft. per hr. Length A. Inspect the system regularly for condensation, corrosion Iron Pipe Size (IPS) — inches of pipe and/or physical damage. A qualified professional should ser- 3 1 1 in Feet 1/2 /4 11 /4 1 /2 vice the boiler annually and include such an inspection at that time. The homeowner should look over the system monthly for 10 132 278 520 1050 1600 damage, water stains, any signs of rust, other corrosion or

Summary of the content on the page No. 15

VICTORY II VHS Models Figure 11a. WATER PIPING Always follow good piping practices. Observe minimum 1" clearance to combustibles around all uninsulated hot water pipes or when openings around pipes are not protected by non-combustible materials. On a hot water boiler installed above radiation level, the boil- er must be provided with a low water cutoff device at the time of installation by the installer. (see Figure 15 for piping arrangement) 1. Supply and Return For tapping sizes see dimensions

Summary of the content on the page No. 16

VICTORY II VHS Models 16

Summary of the content on the page No. 17

VICTORY II VHS Models Figure 14. Figure 15. Piping Arrangement 17

Summary of the content on the page No. 18

VICTORY II VHS Models An automatic air vent is used to remove air from the sys- The air control system and pressure control system must tem. It should be installed in the top of the boiler as shown operate with chiller only, or the boiler only, being valved to the in Figure 15. If system pressure needs further control, add piping system. Separate control devices on the boiler and an additional tank in parallel with original tank or install a chiller may be used, or a single set of air and pressu

Summary of the content on the page No. 19

VICTORY II VHS Models Instructions 9. Set thermostat to desired setting. Follow the lighting instructions in this manual. These instruc- 10. If appliance will not operate, follow the instructions tions are also attached to the boiler. “To Turn Off Gas To Appliance” and call your service or gas supplier. SAFETY INFORMATION For Your Safety Read Before Operating To Turn Off Gas to Appliance 1. Set thermostat to lowest setting. WARNING: If you do not follow these instructions exactly, 2. Turn off

Summary of the content on the page No. 20

VICTORY II VHS Models Gas Rate Table C. Main Burner Ignition Checkout and Pilot Adjustment 1. The pilot flame must not smother or snuff out when Boiler rated input in Cubic Feet Gas Consumption tested as follows: cu. ft./hr. of 1000 Btu/cu. ft. 1000 Btu/cu. ft. gas, in a. Main burner ignition from cold start-repeat. Natural Gas 3 minutes, at rated input b. Continued operation of main burner. 30 1.50 c. Main burner ignition with appliance at maximum 60 3.00 operating temperature after prolonged o


Alternative user manuals
# User manual Category Download
1 Slant/Fin Bobcat B-120 User manual Boiler 6
2 Slant/Fin Bobcat B-200 User manual Boiler 2
3 Slant/Fin Caravan LZDF series User manual Boiler 3
4 Slant/Fin Caravan L-Series User manual Boiler 2
5 Slant/Fin B-120A User manual Boiler 4
6 Slant/Fin CB Series User manual Boiler 12
7 Slant/Fin GALAXY GX User manual Boiler 15
8 Slant/Fin GALAXY GXH User manual Boiler 13
9 Slant/Fin B-200A User manual Boiler 2
10 Slant/Fin Eutectic EC20 User manual Boiler 1
11 Slant/Fin S User manual Boiler 14
12 Slant/Fin Eutectic EC10) User manual Boiler 0
13 Slant/Fin GALAXY GXHA User manual Boiler 2
14 Slant/Fin GALAXY GG User manual Boiler 51
15 Slant/Fin Gas Condensation Within s User manual Boiler 2
16 Sony HDV 1080I HVR-M15N/M15P User manual Boiler 67
17 Sony HDV 1080I HVR-M25N/M25P User manual Boiler 50
18 A.O. Smith 200 User manual Boiler 2
19 A.O. Smith 201 User manual Boiler 7
20 A.O. Smith 750 & 1000 User manual Boiler 6