Carrier Access 52C user manual

User manual for the device Carrier Access 52C

Device: Carrier Access 52C
Category: Air Conditioner
Manufacturer: Carrier Access
Size: 0.96 MB
Added : 3/1/2014
Number of pages: 16
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Carrier Access 52C. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Carrier Access 52C.

For your convenience

If looking through the Carrier Access 52C user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Carrier Access 52C on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Carrier Access 52C to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Carrier Access 52C User manual - Online PDF
Advertisement
« Page 1 of 16 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Carrier Access 52C but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Carrier Access 52C. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

52C
52C
SERIES
SERIES
OWNER’S MANUAL
PACKAGED TERMINAL AIR CONDITIONERS
AND HEAT PUMPS
7,000-15,000 Btuh
CONTENTS
Page Page
GENERAL. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 CARE AND MAINTENANCE . . . . . . . . . . . . . . . . . 10,11
INDOOR-AIR INLET FILTERS . . . . . . . . . . . . . . . . . . 10
UNIT INSPECTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2,3
EXTERNAL PARTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
FRONT PANEL .

Summary of the content on the page No. 2

52C SERIES GENERAL UNIT INSPECTION Thank you for choosing Carrier! You can feel confident Examine unit for damage incurred during shipment. in your selection because the same pride in craftsman- File a claim immediately with the transit company if ship and engineering knowledge that goes into Carrier damage is found. equipment at the Astrodome in Texas, the Sistine The data information plate (Figure 1) lists the model Chapel in Rome, the US Capitol Hall of Congress, and number, voltage rang

Summary of the content on the page No. 3

52 CE A 3 12 3 0 1 AA Series Designation Chassis Options PTAC (Packaged Terminal Air Conditioner) AA – Standard CP – Corrosion Protection RC – Wall Thermostat Control CE – Cooling with Electric Heat RP – Wall Thermostat Control with CQ – Heat Pump Corrosion Protection Latest Revision A – Z Packaging 1 – Domestic Electric Heater Size 2 – 2.3 kW Non-Performance 3 – 3.4 kW Changes 0-9 5 – 5.0 kW Cooling Capacity (nominal) Electrical Data 07 – 7,000 Btuh 3 – 230/208-v, 60

Summary of the content on the page No. 4

52C SERIES  GROUNDING — For safety and protection, the unit ELECTRICAL DATA is grounded through the service cord plug or through separate ground wire provided on hardwired units. Be sure that the branch circuit or general purpose outlet is grounded. ELECTRICAL SHOCK HAZARD TABLE 1 — SUGGESTED BRANCH CIRCUIT DO NOT alter cord or plug, and DO NOT use an WIRE SIZES* extension cord. Personal injury or damage to the unit may result. NAMEPLATE AMPS AWG WIRE SIZE† 7.0 to 12 14 Be sure that your

Summary of the content on the page No. 5

INSTALLATION CHASSIS INSTALLATION FOAM STRIP FOAM STRIP OR BAFFLE OR BAFFLE Units are shipped without a sleeve. In applications where unit is a replacement, it is recommended that a Carrier sleeve be used. The 52C unit can retrofit General Electric, Amana and Trane sleeves/grilles (be sure outdoor grille is installed on the sleeve). A retrofit kit with instructions is included with every unit. See Table 3 for details. Carrier Corporation must approve any other retrofit application. In deep

Summary of the content on the page No. 6

52C SERIES  INSTALL CHASSIS IN SLEEVE (See Figures 6 to 9) SIDE TOP 1. Inspect foam gaskets (top, bottom, both sides) on GASKET GASKET chassis. Replace foam gaskets if torn or missing. IMPORTANT: The gaskets combine with the sleeve face to create a weather barrier. If the chassis is installed in a non-Carrier sleeve, this weather bar- rier may not be effective. Chassis weighs up to 150 lbs. For personal protec- tion, seek help when lifting the unit. Lift unit by holding unit basepan. 2. Re

Summary of the content on the page No. 7

WALL THERMOSTAT INSTALLATION The following instructions apply to RC and RP units 4. Reinstall cover. only. 5. Set desired fan speed using fan switch (unit will NOTE: Carrier thermostats are recommended. See operate only at selected speed). Accessories section. 6. Restore power to unit. NOTE: Refer to thermostat installation instructions IMPORTANT: Only trained, qualified personnel for details on installing thermostat. and service mechanics should install electrical accessories on Carrier 52C

Summary of the content on the page No. 8

52C SERIES OPERATION COMFORT CONTROLS  ADJUST AIRFLOW DIRECTION — The discharge 75 80 air grille is mounted on the front panel so that the air 70 discharges forward. If upward discharge is required, 85 65 60 remove the grille by removing screws on back of front 90 panel. Rotate grille 180 degrees and reinstall on the front panel. TEMPERATURE CONTROL  ADJUST VENT — The vent handle is on the left STANDOFF side of the unit. Turn handle to open or close vent. PINS CON Vent will remain in l

Summary of the content on the page No. 9

(approximately 45° F outdoor air temperature); then OPERATING CONTROLS the electric heater is shut off and the compressor is The following controls are located on the front of the energized. chassis. To obtain access to operating controls, remove the unit front panel as shown on page 2. See Figure 14. IMPORTANT: Once in electric heat mode, the com- pressor is disabled for heating and cooling. IMPORTANT: When unit is first started, high humidity conditions can cause condensation to form To

Summary of the content on the page No. 10

52C SERIES CARE AND MAINTENANCE In order to maintain proper performance of your pack- aged terminal air conditioner or heat pump, it is very important that the fan and outdoor coil, the blower wheel, blower scroll, electric heater, and all drain pas- sages are thoroughly cleaned at least once per year. Carrier recommends that as a minimum, the cleaning should be conducted prior to the start of each heating season. The air inlet filters should be cleaned every month. Depending on local cond

Summary of the content on the page No. 11

EXTERNAL PARTS VENT HANDLE  EXTERNAL PARTS include the polymer sleeve and grilles. The sleeve manufacturer recommends cleaning the surface, including the grilles, with household detergent and water. MAGNET INTERNAL PARTS  INTERNAL PARTS should be cleaned at least once during the year. The outdoor vent filter should be cleaned at least once during a cooling or heating season. Internal parts that should be cleaned include the fol- lowing (see Figures 6, 18, and 19):  Outdoor vent filter

Summary of the content on the page No. 12

52C SERIES PREVENTATIVE MAINTENANCE Preventative maintenance is essential to proper unit operation, efficiency and longevity. To assure equip- ment operates properly it must be properly main- tained. Equipment operation should be checked and verified several times during each year. During regular unit inspection and maintenance, fol- low the guidelines below:  Wash both sides of outdoor coil  Wash basepan and outdoor vent filter  Wash the indoor coil  Clean the blower wheel and front panel

Summary of the content on the page No. 13

TROUBLESHOOTING POSSIBLE CAUSES SOLUTIONS UNIT DOES NOT START • Unit may have become unplugged • Check that plug is securely in wall receptacle. • Fuse may have blown • Replace the fuse. See Note 1. • Circuit breaker may have been tripped • Reset circuit breaker. See Note 1. • Unit mode dial may be set to the OFF position • Switch mode dial to an operating mode. UNIT NOT COOLING/HEATING ROOM • Unit air discharge section is blocked • Make sure that curtains, blinds or furniture are not restrictin

Summary of the content on the page No. 14

52C SERIES ACCESSORIES ACCESSORY FORM NUMBER PART NUMBER DESCRIPTION Wall Sleeves 52S-48SI WALL-SLEEVE-1PK Non-Insulated Plastic Wall Sleeve, 1 per pack WALL-SLEEVE-9PK Non-Insulated Plastic Wall Sleeve, 9 per pack SLEEVE-INSUL-1PK Insulated Plastic Wall Sleeve, 1 per pack 52S-50SI SLEEVE-STEEL-1PK Insulated Metal Wall Sleeve, 1 per pack 52S-49SI* SLEEVE-EXT24-1PK Extended Metal Wall Sleeve for Deep Wall Applications (24 in. deep), 1 per pack Exterior Grilles† 52S-59SI GRILLE-ALU-STAMP Stamped A

Summary of the content on the page No. 15

15

Summary of the content on the page No. 16

52C SERIES Copyright 2001 Carrier Corporation Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations. PC 132 Catalog No. 535-20016 Printed in U.S.A. Form 52C-1SI Pg 16 9-01A 5-01 Replaces: New Book 1 4 Tab 9a 11a


Alternative user manuals
# User manual Category Download
1 Carrier Access 52F Series User manual Air Conditioner 2
2 Carrier Access 52P User manual Air Conditioner 1
3 Sony SU-PW2 User manual Air Conditioner 12
4 Sony CV-P12PX User manual Air Conditioner 3
5 Sony MULTI CHANNEL AV RECEIVER STR-DG710 User manual Air Conditioner 31
6 Sony VGN-BX500 User manual Air Conditioner 1
7 Philips 190S5 User manual Air Conditioner 21
8 Philips Comfort-Cire AMC 45 User manual Air Conditioner 7
9 Philips Comfort-Cire AMC 30 User manual Air Conditioner 2
10 Philips CS-E15DB4EW User manual Air Conditioner 4
11 Philips GOGEAR SA3425 User manual Air Conditioner 1
12 Philips 3160 User manual Air Conditioner 7
13 Philips Comfort-Cire AMW User manual Air Conditioner 3
14 Philips Comfort-Cire AMC 25 User manual Air Conditioner 2
15 Philips GoGear SA3446 User manual Air Conditioner 0