Emerson Liebert XDR user manual

User manual for the device Emerson Liebert XDR

Device: Emerson Liebert XDR
Category: Air Conditioner
Manufacturer: Emerson
Size: 4.06 MB
Added : 3/11/2013
Number of pages: 40
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Emerson Liebert XDR. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Emerson Liebert XDR.

For your convenience

If looking through the Emerson Liebert XDR user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Emerson Liebert XDR on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Emerson Liebert XDR to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Emerson Liebert XDR User manual - Online PDF
Advertisement
« Page 1 of 40 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Emerson Liebert XDR but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Emerson Liebert XDR. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

Precision Cooling
For Business-Critical Continuity™
® ™
Liebert XDR
User Manual

Summary of the content on the page No. 2

IMPORTANT SAFETY GUIDELINES SAVE THESE INSTRUCTIONS WARNING ! Risk of top-heavy module falling over. Can cause equipment damage, personal injury or death. Improper handling can cause equipment damage, injury, or death. Read all of the following instructions before attempting to move, lift, remove packaging from the module, or preparing module for installation. WARNING ! Risk of explosive discharge of high-pressure refrigerant. Can cause personal injury or death. This module contains fluids an

Summary of the content on the page No. 3

TABLE OF CONTENTS IMPORTANT SAFETY GUIDELINES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . INSIDE FRONT COVER 1.0 COMPONENT LOCATIONS AND MODEL NUMBER NOMENCLATURE. . . . . . . . . . . . . . . . . . . . .1 2.0 INTRODUCTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2 2.1 References. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Summary of the content on the page No. 4

6.7 Field Installation of Liebert XD Flex Pipe Kit on Liebert XDR . . . . . . . . . . . . . . . . . . . . . . 18 6.7.1 Connecting Methods—One-Shot Couplings for Pre-Charged Refrigerant Option . . . . . . . . . 19 6.7.2 Connect a Liebert XDR with One-Shot Couplings to Liebert XD Flex Pipe . . . . . . . . . . . . . . 20 6.7.3 Connection Methods—Removable Couplings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 6.7.4 Connect Liebert XD Flex Pipe with Removable Coupli

Summary of the content on the page No. 5

FIGURES Figure 1 Liebert XDR component locations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Figure 2 Liebert XDR model number nomenclature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Figure 3 Generic piping layout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Figure 4 Recommended module handling equipment . . . .

Summary of the content on the page No. 6

iv

Summary of the content on the page No. 7

Component Locations and Model Number Nomenclature 1.0 COMPONENT LOCATIONS AND MODEL NUMBER NOMENCLATURE Figure 1 Liebert XDR component locations 3 2 1 7 4 6 5 1. Supply Line 2. Door Safety Catch 3. Return Line 4. Evaporator Coils 5. Locking Door Latch 6. Removable Installation Handles 7. Frame Figure 2 Liebert XDR model number nomenclature Example: XDR20B1R — * XD R 20 B 1 R — * Liebert 20 = Model Size 1 = Standard - = Domestic Packaging X-treme E = Export Packaging heat density system Rear Co

Summary of the content on the page No. 8

Introduction 2.0 INTRODUCTION 2.1 References This document must be used together with site specific documentation and documentation for other parts of the system. 2.2 Pre-Installation Checks • Check the received materials to be sure all required assemblies and parts have been received. If you discover any external damage, report it to the shipping company and your local Emerson rep- resentative. 2.3 Packing List • User manual (this document) • Liebert XDR module 2.4 Installation Considerations

Summary of the content on the page No. 9

General Product Information 3.0 GENERAL PRODUCT INFORMATION 3.1 Product/System Description The Liebert XDR is a cooling system for high-density heat loads that mounts on the rear of a 24" x 42U rack (for other sizes consult the factory) and maintains access to the back of the server rack. Room air is drawn in through the front of the rack and picks up heat from the servers. The coil captures that heat, cooling the air, which is expelled through the rear of the rack. The Liebert XDR relies on

Summary of the content on the page No. 10

General Product Information 3.2.1 Recyclable Packaging R All material used to package this module is recyclable. Please save for future use or dispose of the material appropriately. CAUTION ! Risk of sharp edges, splinters and exposed fasteners. Can cause personal injury. Only properly trained personnel wearing appropriate safety headgear, gloves, shoes and glasses should attempt to move, lift, remove packaging from, or prepare module for installation. NOTICE Risk of improper storage. Can cau

Summary of the content on the page No. 11

General Product Information 3.2.3 Unpacking the Module WARNING ! Risk of 130-pound (59 kg) module falling. Can cause equipment damage, personal injury or death. Do not leave a Liebert XDR standing unattended on its side or its end without adequate support to prevent it from falling over. The Liebert XDR must be supported at all times or laid flat on protective material until it is installed. Two properly trained and qualified people are required to move the module. Do not unpack the Liebert X

Summary of the content on the page No. 12

General Product Information Figure 5 Removing packaging Step 1 Cut Bands Step 2 Unbend Tabs Hardware Step 3 and Keys Steps 4, and 5 Remove the Top Cover Center Top Brace Step 7 Remove Foam Protecting Top of Module Step 6 Remove Side Panels 6

Summary of the content on the page No. 13

General Product Information Figure 6 Remove Liebert XDR from pallet Two people are required to remove the module from the pallet and remove the bag WARNING ! Risk of 130-pound (59 kg) module falling. Can cause equipment damage, personal injury or death. Do not leave a Liebert XDR standing unattended on its side or its end without adequate support to prevent it from falling over. The Liebert XDR must be supported at all times or laid flat on protective material until it is installed. Two prope

Summary of the content on the page No. 14

Mechanical Considerations 4.0 MECHANICAL CONSIDERATIONS 4.1 Liebert XDR Dimensions The Liebert XDR is engineered to fit on the rear of a rack enclosure measuring approximately 24" x 42U. Consult the factory for other sizes. Figures 7, 8 and 9 illustrate the module’s dimensions and the location of pipes. Figure 11 shows the attachment positions of each module. Figure 7 Overall dimensions with hard-piped connections Piping is not load-bearing and should never be used to lift or 4" (102mm) mov

Summary of the content on the page No. 15

Mechanical Considerations Figure 8 Overall dimensions with one-shot coupling (pre-charged) Piping is not load-bearing and should never be used to lift or 5-1/8" move the Liebert XDR. (130mm) 1-5/16" 1-1/8" (34mm) (29mm) 2-1/8" 1-1/2" (54mm) (38mm) 25-5/8" (651mm) 78-3/8" 20-1/2" 83-1/2" (1991mm) (520mm) (2121mm) 110deg 6-1/2" 5-7/8" (165mm) (149mm) 27-3/8" (695mm) 23-1/2" (597mm) 27-3/8" (695mm) 9

Summary of the content on the page No. 16

Mechanical Considerations Figure 9 Overall dimensions with removable coupling Piping is not load-bearing and 1-1/2" should never be used to lift or (38mm) move the Liebert XDR. 1-5/16" 7/8" (33mm) (22mm) 2-1/8" 1-1/2" (54mm) (38mm) 25-5/8" (651mm) 80" 78-3/8" (2032mm) (1991mm) 20-1/2" 110deg (520mm) 5-7/8" 6-1/2" (149mm) (165mm) 27-3/8" (695mm) 23-1/2" (597mm) 27-3/8" (695mm) 4.2 Determining Placement in the Conditioned Space Refer to site-specific drawings for exact placement. Efficient cooli

Summary of the content on the page No. 17

Mechanical Considerations 4.3 Airflow The server fans draw air into the equipment enclosure. After heated the air, the server fans force the air across the Liebert XDR’s two coils. The Liebert XDR has a low air-side pressure drop (similar to a rack with perforated doors). The server fans within the rack create sufficient airflow to move the air. Figure 10 Generic airflow diagram Enclosure /Rack Shown from Side Refrigerant Connections Liebert XDR Critical Equipment Front Rear of of Rack Ra

Summary of the content on the page No. 18

Installation 5.0 INSTALLATION 5.1 Installing the Rack-Mounting Kit onto the Rack The Liebert XDR module mounts on the rear of the rack using a mounting kit. The mounting kit secures the Liebert XDR's frame to the rack. Two rails are attached to the rear of the rack with M6 x 12 bolts. The number of bolts can vary depending on the rack. Before beginning to attach the rack-mounting brackets to the rack, remove the rear door from the rack. Refer to the rack’s installation manual for details. 1.

Summary of the content on the page No. 19

Installation 5.3 Door Safety Catch The door safety catch prevents the door from opening beyond 110°. When the door is fully open, the safety catch will hold door in place. To release the door, push up on the door catch and close the door. 13

Summary of the content on the page No. 20

Piping 6.0 PIPING Refer to site-specific drawings for general locations of the piping connections. The drawings should specify where the piping connects to the Liebert XDR. 6.1 European Union Fluorinated Greenhouse Gas Requirements Stationary air conditioning, refrigeration, heat pump equipment and stationary fire protection sys- tems in the European Community market and operating with fluorinated greenhouse gases (f-gas), such as R407C, R-134a, R410A, must comply with the F-Gas Regulation: (E


Alternative user manuals
# User manual Category Download
1 Emerson 2 User manual Air Conditioner 81
2 Emerson Precision Cooling For Business-Critical Continuity Figure i User manual Air Conditioner 56
3 Emerson AE8-1385 User manual Air Conditioner 58
4 Emerson 3000 User manual Air Conditioner 221
5 Emerson 1F78H User manual Air Conditioner 31
6 Emerson 3000/ITR User manual Air Conditioner 92
7 Sony SU-PW2 User manual Air Conditioner 12
8 Sony CV-P12PX User manual Air Conditioner 3
9 Sony MULTI CHANNEL AV RECEIVER STR-DG710 User manual Air Conditioner 31
10 Sony VGN-BX500 User manual Air Conditioner 1
11 Philips 190S5 User manual Air Conditioner 21
12 Philips Comfort-Cire AMC 45 User manual Air Conditioner 7
13 Philips Comfort-Cire AMC 30 User manual Air Conditioner 2
14 Philips CS-E15DB4EW User manual Air Conditioner 4
15 Philips GOGEAR SA3425 User manual Air Conditioner 1