Thomas & Betts Limitorque MX Device Net Field Unit user manual

User manual for the device Thomas & Betts Limitorque MX Device Net Field Unit

Device: Thomas & Betts Limitorque MX Device Net Field Unit
Category: Power Supply
Manufacturer: Thomas & Betts
Size: 1.41 MB
Added : 5/28/2013
Number of pages: 44
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Thomas & Betts Limitorque MX Device Net Field Unit. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Thomas & Betts Limitorque MX Device Net Field Unit.

For your convenience

If looking through the Thomas & Betts Limitorque MX Device Net Field Unit user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Thomas & Betts Limitorque MX Device Net Field Unit on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Thomas & Betts Limitorque MX Device Net Field Unit to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Thomas & Betts Limitorque MX Device Net Field Unit User manual - Online PDF
Advertisement
« Page 1 of 44 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Thomas & Betts Limitorque MX Device Net Field Unit but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Thomas & Betts Limitorque MX Device Net Field Unit. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

USER INSTRUCTIONS
Limitorque MX DeviceNet Field Unit Installation
FCD LMENIM2328-00 – 11/05
Operation
Maintenance
Experience In Motion

Summary of the content on the page No. 2

Limitorque MX DeviceNet Field Unit FCD LMENIM2328-00 – 11/05 Limitorque MX DeviceNet Field Unit Installation and Operation Manual ©2005 Copyright Flowserve. All rights reserved. Printed in the United States of America Disclaimer This document is meant for use with the Limitorque MX Installation and Operation Manual for MX-05 through MX-40. Information in this document is also applicable to MX-85 and MX-140. No part of this book shall be reproduced, stored in a retrieval system, or transmitte

Summary of the content on the page No. 3

Limitorque MX DeviceNet Field Unit FCD LMENIM2328-00 – 11/05 Contents Declaration of DeviceNet Conformance – ODVA Certification 5 Abbreviations 6 1 Introduction 7 1.1 Purpose 7 1.2 How to Use this Manual 7 1.3 User Safety 7 1.4 User Knowledge 8 1.5 DeviceNet System Capabilities and Features 8 1.5.1 General Specifications 8 2 System Components 10 2.1 Introduction 10 2.2 Hardware 10 2.2.1 Limitorque MX 10 2.2.2 DeviceNet Field Unit 11 2.2.3 Hardware interface 12 2.2.4 Network Cable 12 3 I

Summary of the content on the page No. 4

Limitorque MX DeviceNet Field Unit FCD LMENIM2328-00 – 11/05 4.5.1 Device Shutdown Message 32 4.6 Configuration Confirmation 32 4.6.1 Checking Connections 32 4.6.2 View Settings 32 5 View DeviceNet Status 33 5.1 Checking the Normal Display 34 5.2 EDS File 35 6 Associated Documents 35 7 Troubleshooting 35 7.1 Workmanship 36 8 How to Order Parts 37 9 Regulatory Information 37 10 Wiring Diagram 38 

Summary of the content on the page No. 5

Limitorque MX DeviceNet Field Unit FCD LMENIM2328-00 – 11/05 Declaration of DeviceNet Conformance – ODVA Certification Declaration of Conformity to the DeviceNet™ Specification ODVA hereby issues this Declaration of Conformity to the DeviceNet™ Specification for the product(s) described below. The Vendor listed below (the "Vendor") has holds a valid the Terms of Usage Agreement for the DeviceNet Technology from ODVA, which is incorporated herein by reference, thereby agreeing that it is t

Summary of the content on the page No. 6

Limitorque MX DeviceNet Field Unit FCD LMENIM2328-00 – 11/05 Abbreviations CIP  Common Industrial Protocol CAN  Controller Area Network COS  Change of State ODVA  Open DeviceNet Vendor Association UCMM  Unconnected Message Manager NV-RO  Non-Volatile Read Only. Data is stored in non-volatile memory and can only be read. Data is stored during Power-Off. For DeviceNet Limitorque Interface this storage area is FLASH NV-RW  Non-Volatile Read Write. Data is stored in non-volatile memory and can be r

Summary of the content on the page No. 7

Limitorque MX DeviceNet Field Unit FCD LMENIM2328-00 – 11/05 1 Introduction 1.1 Purpose This manual explains how to install and operate the Limitorque MX™/DeviceNet field unit (DNFU) and is to be used as an addendum to Bulletin LMENIM2306, Limitorque MX Installation and Operation Manual. Up to 63 actuators, each containing a DeviceNet field unit, may be connected by a single 5 strand, twisted-pair cable to form a DeviceNet network, two wires for connection to the data highway and two wires

Summary of the content on the page No. 8

Limitorque MX DeviceNet Field Unit FCD LMENIM2328-00 – 11/05 a CAUTION: Directs the user’s attention to general precautions that, if not followed, could result in personal injury and/or equipment damage. NOTE: Highlights information critical to the user’s understanding of the actuator’s installation and operation. 1.4 User Knowledge It is recommended that the user read this manual in its entirety before the DeviceNet equipped actuator is installed and operated. The user needs to have a fu

Summary of the content on the page No. 9

Limitorque MX DeviceNet Field Unit FCD LMENIM2328-00 – 11/05 Table 1.1 – Network specifications Network Size Up to 63 Nodes Network Length Selectable end-to-end network distance varies with speed 125 Kbps 500 m (1,640 ft) 250 Kbps 250 m (820 ft) 500 Kbps 100 m (328 ft) Bus Topology Linear (trunkline/dropline); power and signal on the same network cable Bus Addressing Multi-Master and Master/Slave special case; polled of change-of-state (exception-based) System Features Selectable end-to-

Summary of the content on the page No. 10

Limitorque MX DeviceNet Field Unit FCD LMENIM2328-00 – 11/05 2 System Components 2.1 Introduction This section gives an overview of the components used in the DeviceNet system. The field unit is installed in each MX actuator. The network cable connects the field unit to the network via the actuator terminal block. The network cable is connected to a host controller, typically a PLC. 2.2 Hardware NOTE: Recommended storage procedures are detailed in Bulletin LMAIM1314 Limitorque MX Maintenan

Summary of the content on the page No. 11

Limitorque MX DeviceNet Field Unit FCD LMENIM2328-00 – 11/05 The MX features include: • Non-intrusive setup • Separately sealed terminal chamber • Patented absolute encoder for valve position sensing (no battery required) • 32-character LCD for indication and calibration with configuration permitted in six languages. • Sophisticated electronic control, monitoring, and diagnostic capabilities with patented LimiGard™ technology 2.2.2 DeviceNet Field Unit The DeviceNet field unit is installe

Summary of the content on the page No. 12

Limitorque MX DeviceNet Field Unit FCD LMENIM2328-00 – 11/05 2.2.3 Hardware interface The DeviceNet Limitorque Interface is comprised of a minimum of one PCB with two interfaces - One for the DeviceNet Terminal Block connector and one for the SMT Main Board. Figure 2.3 gives an overview about the hardware. The microcontroller on the DeviceNet Limitorque Interface handles the DeviceNet protocol, stores the DeviceNet parameters in an EEPROM, and commu- nicates with the SMT Main Board via SPI. F

Summary of the content on the page No. 13

Limitorque MX DeviceNet Field Unit FCD LMENIM2328-00 – 11/05 Table 2.3 – Total cable length between repeaters or nodes: Network Size 125 KBPS 250 KBPS 500 KBPS Thick Trunk Length 500 m (1,640 ft) 250 m (1,640 ft) 100 m (1,640 ft) Thin Trunk Length 100 m (328 ft) 100 m (328 ft) 100 m (328 ft) Flat Trunk Length 380 m (1,250 ft) 200 m (656 ft) 75 m (246 ft) Maximum Drop Length 6 m (20 ft) 6 m (20 ft) 6 m (20 ft) Cumulative Drop Length 156 m (512 ft) 78 m (256 ft) 39 m (128 ft) Note: Each actuator i

Summary of the content on the page No. 14

Limitorque MX DeviceNet Field Unit FCD LMENIM2328-00 – 11/05 Figure 3.1 – Network cable connection to terminal block NOTE: Recommended DeviceNet cable is Belden 3084A or equal. 121 ohm, ¼ W +/-1% termination resistors must be connected at each segment end. Customer is required to connect wire between terminal 30 and chassis ground for surge protection. Preferred network wiring is to connect shield to terminal 48 for only one unit on each segment. Connect remaining individual network cable shi

Summary of the content on the page No. 15

Limitorque MX DeviceNet Field Unit FCD LMENIM2328-00 – 11/05 NOTE: Ground each segment of the cabling at only one point to prevent ground loops, which can affect system performance. Verify the actuator is properly grounded. 6. Install jumper cable from terminal block pin 30 to earth ground or ground lug. 3.2 Installation Verification 3.2.1 Network Cabling Installation Verification After installation is complete and prior to operation, inspect the network cable and its connection to each fi

Summary of the content on the page No. 16

Limitorque MX DeviceNet Field Unit FCD LMENIM2328-00 – 11/05 4 Object Model Diagram Figure 4.1 – Object Model of DeviceNet Limitorque Interface 4.1 Assembly Objects The Assembly Object binds attributes of multiple objects, which allows data to or from each object to be sent or received over a single connection. Assembly Objects can be used to bind input data or output data. The terms input and output are defined from the networks point of view. An input will produce data on the network and a

Summary of the content on the page No. 17

Limitorque MX DeviceNet Field Unit FCD LMENIM2328-00 – 11/05 • An output is a signal produced at the PLC and sent to the actuator via the network. The user may select one output and one input instance. The default assembly objects are as follows: Polled input - 105, Polled output - 100, Bitstrobe - 107, COS - 109. Table 4.1 Instance  ID  Type  Data  Component  Name  Size  100 Output Output 1 (All Control Channels) 9 101 Output Output 2 (Analog Control and ESD only) 5 102 Output Output 3 (

Summary of the content on the page No. 18

Limitorque MX DeviceNet Field Unit FCD LMENIM2328-00 – 11/05 Table 4.4 – Output Assembly Instance 102 Class  Attribute  Assembly  Data  Instance  Object  Component  Data  ID  ID  Name  ID  Name  Instance  ID  Name  Type  102 Output 3 100 Channel 1 20 Ctrl_Status_Chan BYTE Interface 100 Channel 1 9 DO_Position_Chan BYTE Interface 100 Channel 1 21 DO_ESD_Poll_Cnxn BOOL Interface 100 Channel 1 18 DO_Move_ Test_Chan BOOL Interface Table 4.5 – Output Assembly Instance 103 Class  Attribut

Summary of the content on the page No. 19

Limitorque MX DeviceNet Field Unit FCD LMENIM2328-00 – 11/05 Table 4.7 – Input Assembly Instance 105 Class  Attribute  Assembly  Data  Instance  Object  Component  Data  ID  ID  Name  ID  Name  Instance  ID  Name  Type  105 Input 1 100 Channel 1 17 DI_Actuator_ BYTE Interface Faults_3_Chan 100 Channel 1 4 DI_Actuator_ BYTE Interface Faults_1_Chan 100 Channel 1 6 DI_Actuator_ Alarms_Chan BYTE Interface 100 Channel 1 2 DI_Pos_And_ BYTE Interface Bus_Mode_Chan 100 Channel 1 5 DI_Actuat

Summary of the content on the page No. 20

Limitorque MX DeviceNet Field Unit FCD LMENIM2328-00 – 11/05 Table 4.9 – Input Assembly Instance 107 Class  Attribute  Assembly  Data  Instance  Object  Component  Data  ID  ID  Name  ID  Name  Instance  ID  Name  Type  107 Input 3 100 Channel 1 17 DI_Actuator_ BYTE Interface Faults_3_Chan 100 Channel 1 4 DI_Actuator_ BYTE Interface Faults_1_Chan 100 Channel 1 6 DI_Actuator_ Alarms_Chan BYTE Interface 100 Channel 1 2 DI_Pos_And_ BYTE Interface Bus_Mode_Chan 100 Channel 1 12 AI_Positi


Alternative user manuals
# User manual Category Download
1 Thomas & Betts 9395 User manual Power Supply 1
2 Sony AC U50A User manual Power Supply 5
3 Sony AC LS1 User manual Power Supply 2
4 Sony NP-FM30 User manual Power Supply 35
5 Sony NP FX101 User manual Power Supply 1
6 Sony NH-AAA-DA User manual Power Supply 2
7 3Com 3645A User manual Power Supply 0
8 3Com 3CNJPSE24 User manual Power Supply 2
9 3Com COREBUILDER 5000 User manual Power Supply 0
10 3Com 3646A User manual Power Supply 0
11 3Com External PoE Power System PSE2500-A3 User manual Power Supply 1
12 Sony AC E45HG User manual Power Supply 10
13 3Com Powerware Uninterruptible Power System Prestige Series User manual Power Supply 7
14 AB Soft ATX 12V User manual Power Supply 0
15 AC International Lenze SV01B User manual Power Supply 8