Fujitsu PRIMERGY BX400 S1 user manual

User manual for the device Fujitsu PRIMERGY BX400 S1

Device: Fujitsu PRIMERGY BX400 S1
Category: Server
Manufacturer: Fujitsu
Size: 3.52 MB
Added : 11/5/2013
Number of pages: 130
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Fujitsu PRIMERGY BX400 S1. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Fujitsu PRIMERGY BX400 S1.

For your convenience

If looking through the Fujitsu PRIMERGY BX400 S1 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Fujitsu PRIMERGY BX400 S1 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Fujitsu PRIMERGY BX400 S1 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Fujitsu PRIMERGY BX400 S1 User manual - Online PDF
Advertisement
« Page 1 of 130 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Fujitsu PRIMERGY BX400 S1 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Fujitsu PRIMERGY BX400 S1. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 18

Introduction ● Watchdog timer for Automatic Server Reconfiguration and Restart (ASR&R) in the event that memory modules or processors fail ● Power monitoring ● End-of-life monitoring of fans with prompt notification before failure ● Watchdog timer for monitoring the operating system with ASR&R Further information on the ServerView Operations Manager is provided in the associated documentation. Service and support PRIMERGY servers are easy to maintain and modular, thus enabling quick and simpl

Summary of the content on the page No. 19

Introduction 1.4 Notational conventions The following notational conventions are used in this manual: Text in italics indicates commands or menu items. "Quotation marks" indicate names of chapters and terms that are being emphasized. Ê describes activities that must be performed in the order shown. V CAUTION! pay particular attention to texts marked with this symbol. Failure to observe this warning may endanger your life, destroy the system or lead to the loss of data. I indicates additional

Summary of the content on the page No. 20

Introduction 1.5 Technical data Electrical data (hot-plug power supply unit) Rated voltage range 100 - 240 V Frequency 50Hz-60Hz Max. rated current 45 A / 22.5 A (100-240 V) Effective power 1785 W (240 V) 1200 W (100 V) Apparent power 1821 VA (240 V) 1265 VA (100 V) Heat dissipation 11520 kJ/h (with 3200 W) 5760 kJ/h (with1600 W) Main power fuse 16 A Protection class I Compliance with regulations and standards Product safety and IEC 60950-1 / EN 60950-1, UL/CSA 60950-1 (all ergonomics second e

Summary of the content on the page No. 1

Operating Manual - English
PRIMERGY BX400 S1
Blade Server Version
System Unit Operating Manual
May 2011

Summary of the content on the page No. 2

Comments… Suggestions… Corrections… The User Documentation Department would like to know your opinion of this manual. Your feedback helps us optimize our documentation to suit your individual needs. Feel free to send us your comments by e-mail to manuals@ts.fujitsu.com. Certified documentation according to DIN EN ISO 9001:2008 To ensure a consistently high quality standard and user-friendliness, this documentation was created to meet the regulations of a quality management system which compl

Summary of the content on the page No. 3

Before reading this manual For your safety This manual contains important information for safely and correctly using this product. Carefully read the manual before using this product. Pay particular attention to the accompanying manual "Safety Notes and Regulations" and ensure these safety notes are understood before using the product. Keep this manual and the manual "Safety Notes and Regulations" in a safe place for easy reference while using this product. Radio interference This product

Summary of the content on the page No. 4

These uses include control of nuclear reactions in nuclear power plants, automatic airplane flight control, air traffic control, traffic control in mass transport systems, medical devices for life support, and missile guidance control in weapons systems (hereafter, "high safety use"). Customers should not use this product for high safety use unless measures are in place for ensuring the level of safety demanded of such use. Please consult the sales staff of Fujitsu if intending to use this

Summary of the content on the page No. 5

Only for the Japanese market: I Although described in this manual, some sections do not apply to the Japanese market. These options and routines include: – CSS (Customer Self Service) BX400 S1 Operating Manual 5

Summary of the content on the page No. 6

6 Operating Manual BX400 S1 © cognitas. Gesellschft für Technik-Dokumentation mbH 2009 Pfad: C:\Programme\FCT\tim_app\tim_local\work\WALTER\OBJ_DOKU-9240-003.fm

Summary of the content on the page No. 7

Contents 1 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 1.1 Concept and target groups for this manual . . . . . . . . . 11 1.2 Documentation overview . . . . . . . . . . . . . . . . . . . 12 1.3 Performance features . . . . . . . . . . . . . . . . . . . . . 13 1.4 Notational conventions . . . . . . . . . . . . . . . . . . . . 19 1.5 Technical data . . . . . . . .

Summary of the content on the page No. 8

Contents 4.6.1 Using cable ties . . . . . . . . . . . . . . . . . . . . . . . . . . 53 4.7 Instructions for connecting/disconnecting cables . . . . . . 54 5 Installation and operation . . . . . . . . . . . . . . . . . . . . 55 5.1 Control and display elements . . . . . . . . . . . . . . . . . 55 5.1.1 Front of system . . . . . . . . . . . . . . . . . . . . . . . . . . 55 5.1.1.1 Control elements . . .

Summary of the content on the page No. 9

Contents 8.2.5 Connection Blade Ethernet Pass Thru 10Gb 18/18 . . . . . . . 99 8.2.6 Connection Blade 8Gb FC Switch 18/8 . . . . . . . . . . . . . 102 8.2.7 Connection Blade 8Gb FC Pass Thru 18/18 . . . . . . . . . . 104 8.2.8 Connection Blade Infiniband Switch 40 Gb 18/18 . . . . . . . 106 8.2.9 Fitting rules for connection blades . . . . . . . . . . . . . . . . 108 8.2.10 Port assignment of the connection blades . . . . . . . . . .

Summary of the content on the page No. 10

Contents 10 Operating Manual BX400 S1 © cognitas. Gesellschft für Technik-Dokumentation mbH 2009 Pfad: C:\Programme\FCT\tim_app\tim_local\work\WALTER\OBJ_DOKU-9241-003.fm

Summary of the content on the page No. 11

1 Introduction The PRIMERGY BX400 S1 blade server is a highly compact, energy-saving and scalable server system for installation in a 19-inch rack or as a floorstand model. The BX400 S1 system unit offers 8 slots for a mixture of server blades and storage blades (therein a maximum of 4 single-slot storage-blades respectively 2 double-slot JBOD blades). With its advanced infrastructure modules, the BX400 S1 system unit offers the server blades a high level of connectivity and availability. T

Summary of the content on the page No. 12

Introduction 1.2 Documentation overview More information on your PRIMERGY BX400 S1 system unit can be found in the following documents: – "Quick Start Hardware - PRIMERGY BX400 S1" leaflet " はじめ にお読みくだ さい -PRIMERGY BX400 S1" for the Japanese market (only included as a printed copy) – "Safety Notes and Regulations" manual " 安全上のご注 意 " for the Japanese market – "Warranty" manual " 保証書 " for the Japanese market – "ServerView Suite Local Service Concept - LSC" manual – "Returning used devices" man

Summary of the content on the page No. 13

Introduction – Documentation on the server blades and storage blades – The manual "PRIMERGY BX400 Blade Server Systems ServerView Management Blade S1 User Interface Description" 1.3 Performance features Customer Self Service (CSS) The Fujitsu Technology Solutions Customer Self Service (CSS) concept enables you to identify and replace the affected component yourself in the case of certain error scenarios. In the CSS concept, you can replace the following components yourself in the event of an

Summary of the content on the page No. 14

Introduction In the event of errors, the ServerView Operations Manager refers you directly to the affected component and its order information in the Illustrated Spares catalog of the server in question. (This feature is not available for the Japanese market.) Server performance The system unit has 8 slots for server blades. Four server blade slots can be fitted with storage blades (or six slots with JBODs) which provide additional storage capacity for the neighboring server blades. For inf

Summary of the content on the page No. 15

Introduction – Connection Blade 1GbE Switch/IBP 18/6 (SB 6) – 18 internal 1-Gbit ports to the server blades – 6 external 1-Gbit ports through SFP+ modules or active twinax cables (copper) I This connection blade can be used in all connection blade slots. – Connection Blade 10 GbE Switch/IBP 18/8 – 18 internal 10-Gbit ports to the server blades – 8 external 10-Gbit ports through SFP+ modules or active twinax cables (copper) I This connection blade can be used in all connection blade slots. 10

Summary of the content on the page No. 16

Introduction – Connection Blade 8Gb FC Pass Thru18/18 – 18 internal 8-Gbit ports to the server blades – 18 external ports through 8-Gb SFP+ modules or 4-Gb SFP modules I Fibre Channel connection blades can only be installed in slots CB3/4 (fabric 3)and only support server blades that are fitted with a Fibre Channel mezzanine card. ● Infiniband connection blade – Connection Blade Infiniband Switch 40 Gb 18/18 – 18 internal 40-Gbit Infiniband ports to the server blades – 18 external 40-Gbit I

Summary of the content on the page No. 17

Introduction Cooling Cooling of the system is ensured by two fans in each power supply unit and by the fan modules. Each of the fan units contains 2 fans. The fan modules have the same aspect ratio as the power supply units. Empty power supply installation bays must be fitted with fan modules. The configuration is redundant and offers hot-swap functionality (for more information, see "Hot-plug power supply units" on page 119). High level of availability and failure protection ASR&R (Automat


Alternative user manuals
# User manual Category Download
1 Fujitsu BX900 S1 User manual Server 23
2 Fujitsu 2000 User manual Server 1
3 Fujitsu CM71-00101-5E User manual Server 1
4 Fujitsu 5.0L10 User manual Server 1
5 Fujitsu 2000 SERIES User manual Server 1
6 Fujitsu Cloud Edition V3.1.0 User manual Server 0
7 Fujitsu C122-E180-01EN User manual Server 0
8 Fujitsu C120-E361-04EN User manual Server 2
9 Fujitsu M10-4S User manual Server 0
10 Fujitsu M10 User manual Server 1
11 Fujitsu M10-4 User manual Server 0
12 Fujitsu C122-H007-01EN User manual Server 0
13 Fujitsu J2X0-2273-01EN User manual Server 0
14 Fujitsu M8000 User manual Server 0
15 Fujitsu RX300 S2 User manual Server 25
16 Edelbrock 1921 User manual Server 0
17 Sony VAIO VGF-HS1 User manual Server 11
18 Sony NAS-SV20DI User manual Server 1
19 3Com 10031370-01 User manual Server 1
20 3Com SuperStack 3 User manual Server 9