GE JV322 user manual

User manual for the device GE JV322

Device: GE JV322
Category: Ventilation Hood
Manufacturer: GE
Size: 0.28 MB
Added : 6/23/2014
Number of pages: 12
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for GE JV322. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with GE JV322.

For your convenience

If looking through the GE JV322 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual GE JV322 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual GE JV322 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
GE JV322 User manual - Online PDF
Advertisement
« Page 1 of 12 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual GE JV322 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to GE JV322. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

Use and Care of Recirculation Hood Models JN322, JN334, JN335,
JMW, & JN635 and Ventilating Hood Models JV322, JV324, JV332,
JV334, JV335, JV624, JV634, & JV635
C. When cutting or drilling into wall or ceiling,
IMPORTANT SAFETY
do not damage electrical wiring and other
INSTRUCTIONS hidden utilities.
D. Ducted fans must always be vented to
WARNING- TO REDUCE THE RISK
the outdoors.
OF FIRE, ELECTRIC SHOCK, OR
E. If this unit is to be installed over a tub or
INJURY TO PERSONS, OBSERVE
shower, it mu

Summary of the content on the page No. 2

If You Need Service... ● Do not attempt to repair or replace any part of 1 IMPORTANT SAFETY your hood unless it is speciikxdly recommended INSTRUCTIONS {continu~) in this book. All other servicing should be referred to a qualified technician. WARNING TO REDUCE THE RISK ● Disconnect hood circuit breaker or fuse before OF INJURY TO PERSONS ~ T~ performing any service. EVENT OF A RANGE TOP GREASE “A” Models: JN322, JN334, JN335, JN634 & JN635 FIRE, OBSERVE THE FOLLOWING: ‘“,a,eoremovehe fi,ter A. S

Summary of the content on the page No. 3

To remove: Turn the retaining clip to release the edge of To Operate the filter. The filter will then slip out of the retaining tabs. —Vents To clean: Soak and then agitate in a hot detergent (“JN” models only) solution. Light brushing may be used to remove irnbedded soil. Rinse, shake and remove moisture before replacing. With careful handling, the filter will last for yean. If replacement becomes necessary, order the part from your dealer. Lamp switch Fan switch Trim To replace: Slip the edge

Summary of the content on the page No. 4

Installation Instructions for General Electric Hood Models: JN322, JN334, JN335, JN634, JN635, JV322, JV324, JV332, JV334, JV335, JV624, JV634, JV635 Important-save for the local electrical inspector% use Power supply connection box on underside of hood. I 7%” ~pe “C” Y~ models Exhaust Outlet Knockouts — 4

Summary of the content on the page No. 5

1. PREPARATION OF WALL CABINET AND WALL FLUSH OR RECESSED BOITOM CABINET NOTE: For easier installation make all hood and vent cutouts in the cabinet and wall before cabinet is permanently fastened in place. It is recommended that the power supply be brought into the hood from the wall below the cabinet as shown in Fig. 1. However, an optional location is shown in Fig. 2, where the power supply enters the top of the hood by passing through the wall cabinet. A. WALL CABINET WITH RECESSED BOTTOM: -

Summary of the content on the page No. 6

2. DUCT INSTALLATION Total Equivalent Number Equivalent T@e “B” Models: See Figs. 4 and 9. . Duct Pieces Length Used Length The hood exhaust has been designed to mate with standard 7“ round duct. (A round damper kit may be a ‘:~:::$ 5 feet ordered. Order GE model number JXDA22.)* 3%’’ X1O” A. If a rectangular duct is desired, a round-to-rectangular straight 2.5 feet D adapter must be used. Install a 4“ minimum length of 7“ round duct between the hood and adapter to obtain 6“, proper operation of

Summary of the content on the page No. 7

3. POWER SUPPLY A. CIRCUIT VOLTAGE: This hood must be connected Centerline of hood to a supply circuit of the proper voltage and frequency as specified on the rating plate. Wire size must conform to the requirements of the National Electrical Code or the prevailing local code for hoods of this rating. The rating plate is located on the rear wall of the hood. B. FUSE RATING: 15 amPS. C. Unless otherwise specified by local codes, bring a 15 amp 2 wire circuit with ground to the area of the power s

Summary of the content on the page No. 8

IMPORTANT: After installation, peel off the transparent protective film stripping from the decorative trim on the front of the hood. (See Fig. 12.) B. ELECTRICAL CONNECTION Protective Film 1. Be sure the power supply is disconnected before making electrical connections. FIGURE 12 2. Remove the connection box cover located on the left side of the fan unit. 3. Attach the power supply through the knockout hole in the back or top of the hood. 4. Connect the colored incoming power supply Wire nuts le

Summary of the content on the page No. 9

Remove the lamp and replace with an ordinary screw- Lamp Replacement base lamp bulb NOT MORE THAN 60 WATTS. To remove the lamp cover, if desired: Models JN334, JN335, JN634, ● Press the sides with 2 fingers until the side prongs JN635, JV324, JV334, JV335, are released. JV624, JV634, JV635 have a ● Lift the lamp cover and slide towards you in one lamp cover. motion. The lamp cover need not be To replace the lamp cover: removed for lamp removal ● Insert the prong located at the end of the cover i

Summary of the content on the page No. 10

Questions? Use This Problem Solver PROBLEM POSSIBLE CAUSE FAN DOES NOT ● A fuse may be blown or a circuit breaker tripped. Replace fuse or reset circuit breaker. OPERATE WHEN THE SWITCH IS ON . Fan blade striking the hcmd sheI1. FAN FAILS TO CIRCULATE AIR s Excessively soiled filter should be checked and corrected before using the hood again. FAN OPERATES BUT - Check to be sure the filter is clean. If replacing the filter does not correct the problem, MOVES AIR SLOWER call for service. THAN NORM

Summary of the content on the page No. 11

If You Need Service Help Us Help You... To obtain service, see your warranty on the back page Write down the model and serial of this book. numbers. We’re proud of our service and want you to be pleased. You’ll find them on a label on the back wall of If for some reason you are not happy with the service the hood. These numbers are also on the Consumer you receive, here are 3 steps to follow for further help. Product Ownership Registration Card that came with your hood. Before sending in this ca

Summary of the content on the page No. 12

Staple sales slip or cancelled check YOUR RANGE HOOD here. Proof of original purchase date WARRANTY is needed to obtain service I — under warranty. FULL ONE-YEAR WARRANTY This warranty is extended to WHAT IS COVERED the original purchaser and any For one year from date of original succeeding owner for products purchase, we will provide, free of purchased for ordinary home use in charge, parts and service labor in the 48 mainland states, Hawaii and your home to repair or replace any Washington, D


Alternative user manuals
# User manual Category Download
1 GE BF120 User manual Ventilation Hood 17
2 GE BF50 User manual Ventilation Hood 5
3 GE BF150A User manual Ventilation Hood 2
4 GE 30" User manual Ventilation Hood 1
5 GE BF50A User manual Ventilation Hood 2
6 GE BF60 User manual Ventilation Hood 2
7 GE BF60CP User manual Ventilation Hood 1
8 GE BF150 User manual Ventilation Hood 4
9 GE BF60CPA User manual Ventilation Hood 0
10 GE BF100S User manual Ventilation Hood 0
11 GE BF60A User manual Ventilation Hood 0
12 GE BF70A User manual Ventilation Hood 0
13 GE BF85 User manual Ventilation Hood 0
14 GE BF75 User manual Ventilation Hood 0
15 GE BF85A User manual Ventilation Hood 0
16 Sony SH-L35W User manual Ventilation Hood 0
17 Air King AIF8X User manual Ventilation Hood 3
18 Acme Kitchenettes Koolmaster PP-32 User manual Ventilation Hood 0
19 Air King AIF10X User manual Ventilation Hood 0
20 Agilent Technologies 31A User manual Ventilation Hood 0