American Standard Copeland T005.730 user manual

User manual for the device American Standard Copeland T005.730

Device: American Standard Copeland T005.730
Category: Thermostat
Manufacturer: American Standard
Size: 0.65 MB
Added : 6/22/2013
Number of pages: 9
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for American Standard Copeland T005.730. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with American Standard Copeland T005.730.

For your convenience

If looking through the American Standard Copeland T005.730 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual American Standard Copeland T005.730 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual American Standard Copeland T005.730 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
American Standard Copeland T005.730 User manual - Online PDF
Advertisement
« Page 1 of 9 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual American Standard Copeland T005.730 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to American Standard Copeland T005.730. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

Installation
Instructions
COPELAND
T005.730
CENTRAL THERMOSTAT
LESS VOLUME CONTROL
TRIM KIT
Thank you for selecting American-Standard...the
benchmark of fine quality for over 100 years.
Certified to comply with ANSI A112.18.1M
To ensure that your installation proceeds smoothly--please
ASSE 1016
read these instructions carefully before you begin.
M968014
ROUGHING-IN DIMENSIONS
R510
1/2 NPT
R530
3/4 NPT
192.6mm
(7-9/16)
86mm
R510
(3-3/8)
1/2 NPT
34mm
R530
(1-3/8)
3/4 NPT
77mm
(3-1/16)
25mm
(1)
48mm

Summary of the content on the page No. 2

TRIM INSTALLATION 1 1 3 2 Push CAP (1) over the O-RING SEAL (2). Push ESCUTCHEON HOLDER (3) with lightly greased O-RING SEAL (4) over CAP (1). Attach the FIXATION PLATE (7) to the ESCUTCHEON HOLDER (3) with the two SCREWS (5) provided. GREASE ESCUTCHEON 4 O-RING SEAL Push ESCUTCHEON (6) flush against finished wall. 7 6 2 HANDLE INSTALLATION 2 Install HANDLE BASE (1) onto TEMPERATURE CONTROL KNOB (2) 4 Install HANDLE ADAPTER (3) onto HANDLE BASE (1) and tighten with SCREW (4). Align HANDLE (5) a

Summary of the content on the page No. 3

COPELAND CENTRAL THERMOSTAT LESS VOLUME CONTROL TRIM KIT MODEL NUMBERS T005.730 M962630-0070A ESCUTCHEON HOLDER A924335-0070A FIXATION PLATE M907593-YYY0A ESCUTCHEON KIT A907090-YYY0A CAP 023774-0070A ESCUTCHEON SCREWS M916586-YYY0A HANDLE BASE M918053-0070A ADAPTER M918349-0070A SELF TAPPING SCREW M962729-YYY0A HANDLE KIT Replace the "YYY" with appropriate finish code CHROME 002 BLACKENED BRONZE 068 SATIN NICKEL 295 HOT LINE FOR HELP For toll-free information and answers to your questions, call:

Summary of the content on the page No. 4

Installation Directives COPELAND T005.730 THERMOSTAT CENTRAL CONTRÔLE DE VOLUME JEU DE GARNITURE Nous vous remercions d'avoir choisi American Standard… synonyme de qualité supérieure depuis plus de 100 ans. Pour que l’installation se déroule sans problème, Certifié conforme aux normes ANSI A112.18.1M ASSE 1016 veuillez lire attentivement ces instructions avant de commencer. M968014 MESURES RELATIVES AUX POINTS DE RACCORDEMENT R510 ½ NPT R530 ¾ NPT 192,6 mm (7 9/16) 86 mm R510 (3 3/8) ½ NPT 34

Summary of the content on the page No. 5

INSTALLATION DE LA GARNITURE 1 1 3 2 Enlever les PROTECTIONS DE PLÂTRE, si fixées. Pousser les CAPUCHONS (1) comme 5 illustré sur les VANNES DE RÉGLAGE (2). Pousser le SUPPORT DE ROSACE (3) sur les CAPUCHON (4) les JOINTS TORIQUE (1) doivent être légèrement graissés. 4 Fixer la PLAQUE DE FIXATION (7) à l’aide des deux VIS (5) fournies. Pousser la ROSACE (6) contre le mur fini. 7 6 2 INSTALLATION DE LA POIGNÉE 2 Installer la BASE DE LA POIGNÉE (1) sur le 4 BOUTON DE COMMANDE DE TEMPÉRATURE (

Summary of the content on the page No. 6

COPELAND THERMOSTAT CENTRAL CONTRÔLE DE VOLUME JEU DE GARNITURE NUMÉROS DE MODÈLE T005.730 M962630-0070A SUPPORT DE ROSACE A924335-0070A PLAQUE DE FIXATION M907593-YYY0A ENSEMBLE DE ROSACE A907090-YYY0A CAPUCHON 023774-0070A VIS DE ROSACE M916586-YYY0A SOCLE DE POIGNÉE M918053-0070A ADAPTATEUR M918349-0070A VIS À AUTO-FILETAGE M962729-YYY0A TROUSSE DE LA POIGNÉE Remplacer les « YYY » par Code approprié du fini CHROME 002 BRONZE FUMÉ 068 NICKEL SATINÉ 295 LIGNE D’URGENCE Pour obtenir des renseign

Summary of the content on the page No. 7

Instrucciones de Instalación COPELAND T005.730 TERMOSTATO CENTRAL CONTROL DE MENOS VOLUMEN JUEGO DE MOLDURA Gracias por elegir American Standard, el referente de calidad por más de 100 años. Cumplimiento certificado de la norma ANSI A112.18.1M Para asegurarse de realizar la instalación sin inconvenientes, ASSE 1016 lea cuidadosamente estas instrucciones antes de comenzar. M968014 DIMENSIONES DE INSTALACIÓN R510 1/2 NPT R530 3/4 NPT 192. 6mm (7-9/16) 86mm R510 (3-3/8) 1/2 NPT 34mm R530 (1-3/8)

Summary of the content on the page No. 8

INSTALACIÓN DE LA MOLDURA 1 1 3 2 Retire el PROTECTOR DE YESO (1) si se incluye. 5 Presione las TAPA (2) como se muestra sobre las VÁLVULAS DE CONTROL (3). Coloar la base de la placa (4) con los empaques de anillo O-ring (5) ligeramente enqrasados sobre ENGRASE EL CHAPETÓN 4 las tapa (2). SELLO DE ARO TÓRICO Acoplav la base de fijación (7) con la base de la placa (4) con los (6) tornillos incluidos. 7 6 2 INSTALACIÓN DE LA MANIJA 2 Instale la BASE DE LA MANIJA (1) en la PERILLA DE CONTROL 4 D

Summary of the content on the page No. 9

COPELAND TERMOSTATO CENTRAL CONTROL DE MENOS VOLUMEN JUEGO DE MOLDURA NÚMEROS DE MODELOS T005.730 M962630-0070A SUJETADOR DEL CHAPETÓN A924335-0070A FIXATION PLATE M907593-YYY0A JUEGO DEL CHAPETÓN A907090-YYY0A TAPA 023774-0070A TORNILLOS DEL CHAPETÓN M916586-YYY0A BASE DE LA MANIJA M918053-0070A ADAPTADOR M918349-0070A TORNILLO AUTOROSCANTE M962729-YYY0A JUEGO DE LA MANIJA Reemplace las "YYY" con el código de acabado correspondiente. CROMO 002 BRONCE ENEGRECIDO 068 NÍQUEL SATINADO 295 ASISTEN


Alternative user manuals
# User manual Category Download
1 American Standard asystat 570 User manual Thermostat 4
2 American Standard CERATHERM T050110 User manual Thermostat 2
3 American Standard ASYSTAT500C User manual Thermostat 5
4 American Standard 340 User manual Thermostat 0
5 American Standard ASYSTAT302C User manual Thermostat 0
6 American Standard Enfield T373.730 User manual Thermostat 0
7 American Standard Ceratherm T203.740 User manual Thermostat 0
8 American Standard Ceratherm T050.541 User manual Thermostat 4
9 American Standard R520 User manual Thermostat 0
10 American Standard Moments T506.740 User manual Thermostat 0
11 American Standard Moments R510 User manual Thermostat 0
12 American Standard T010.730 User manual Thermostat 1
13 American Standard One T064.740 User manual Thermostat 2
14 American Standard M968983 User manual Thermostat 0
15 American Standard Moments T506.730 User manual Thermostat 0
16 Edelbrock 2116 User manual Thermostat 0
17 A&D MF-50 User manual Thermostat 8
18 A&D ML-50 User manual Thermostat 8
19 A&D MS-70 User manual Thermostat 15
20 Acu-Rite D1523 User manual Thermostat 2