Lux Products PSP722E user manual

User manual for the device Lux Products PSP722E

Device: Lux Products PSP722E
Category: Thermostat
Manufacturer: Lux Products
Size: 0.91 MB
Added : 12/16/2013
Number of pages: 16
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Lux Products PSP722E. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Lux Products PSP722E.

For your convenience

If looking through the Lux Products PSP722E user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Lux Products PSP722E on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Lux Products PSP722E to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Lux Products PSP722E User manual - Online PDF
Advertisement
« Page 1 of 16 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Lux Products PSP722E but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Lux Products PSP722E. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

Stage one of a cooling system will be deactivated at the
4.4.4 COPY PROGRAMMING value of swing 1 below the temperature set point.
PSP722E

The COPY button allows you to easily copy temperature Stage two of a heating system will be activated at the
or fan programs from any day, to any other day, to all value of (swing 1 + swing 2) below the temperature set
52026
weekdays, to both weekend days, or all days. The Copy point. The auxiliary heat indicator AUX HT will be visible
function copies only t

Summary of the content on the page No. 2

● On replacement installations, mount the new thermostat Route the wires through the open areas in the base in place of the old one unless the conditions listed below plate above the terminals. Hold the base against the wall, LARGE HYBRID DISPLAY suggest otherwise. On new installations, follow the with the wires coming through. Position the base for the WITH ELECTRO-LUMINESCENT guidelines listed below. best appearance (to hide any marks from an old thermo- DISPLAY BACKLIGHT ● stat). Attach the b

Summary of the content on the page No. 3

● On replacement installations, mount the new thermostat Route the wires through the open areas in the base in place of the old one unless the conditions listed below plate above the terminals. Hold the base against the wall, LARGE HYBRID DISPLAY suggest otherwise. On new installations, follow the with the wires coming through. Position the base for the WITH ELECTRO-LUMINESCENT guidelines listed below. best appearance (to hide any marks from an old thermo- DISPLAY BACKLIGHT ● stat). Attach the b

Summary of the content on the page No. 4

9. W2 This terminal is active when the thermostat common to power the thermostat from the system in any PUMP SYSTEM LABEL CROSS REFERENCE is calling for a second stage of furnace or electric wiring configuration. Previous Thermostat New Thermostat heat. It will remain inactive unless two stages of System Terminal Marking Terminals Wire To WARNINGS: 1. A B wire is sometimes used as a heating have been specified in the installer setup Heat Pump common wire. Connecting a common B wire to the B ter

Summary of the content on the page No. 5

9. W2 This terminal is active when the thermostat common to power the thermostat from the system in any PUMP SYSTEM LABEL CROSS REFERENCE is calling for a second stage of furnace or electric wiring configuration. Previous Thermostat New Thermostat heat. It will remain inactive unless two stages of System Terminal Marking Terminals Wire To WARNINGS: 1. A B wire is sometimes used as a heating have been specified in the installer setup Heat Pump common wire. Connecting a common B wire to the B ter

Summary of the content on the page No. 6

TYPICAL INSTALLER SETUP: TYPICAL INSTALLER SETUP: TYPICAL 24VAC 4 WIRE HOOKUP TYPICAL SINGLE-STAGE HEAT PUMP WITH [01] SYSTEM TYPE = FURNACE [01] SYSTEM TYPE = HEAT PUMP SINGLE STAGE HEATING AND COOLING (2 STAGES HEAT AND 1 STAGE COOL) [02] HEAT STAGES =1 [02] HEAT STAGES =1 OPTIONAL AUX AND EMERGENCY HEAT [03] COMPRESSOR STAGES = 1 [03] COMPRESSOR STAGES = 1 [04] [04] MODES = Ht-Off-Cl-Auto MODES = Ht-Off-Cl- G O Y2 Y1 RC C RH W1 W2 E B G O Y2 Y1 RC C RH W1 W2 E B EmHt-Auto [09] HEAT FAN CONTR

Summary of the content on the page No. 7

TYPICAL INSTALLER SETUP: TYPICAL INSTALLER SETUP: TYPICAL 24VAC 4 WIRE HOOKUP TYPICAL SINGLE-STAGE HEAT PUMP WITH [01] SYSTEM TYPE = FURNACE [01] SYSTEM TYPE = HEAT PUMP SINGLE STAGE HEATING AND COOLING (2 STAGES HEAT AND 1 STAGE COOL) [02] HEAT STAGES =1 [02] HEAT STAGES =1 OPTIONAL AUX AND EMERGENCY HEAT [03] COMPRESSOR STAGES = 1 [03] COMPRESSOR STAGES = 1 [04] [04] MODES = Ht-Off-Cl-Auto MODES = Ht-Off-Cl- G O Y2 Y1 RC C RH W1 W2 E B G O Y2 Y1 RC C RH W1 W2 E B EmHt-Auto [09] HEAT FAN CONTR

Summary of the content on the page No. 8

3.6. INSTALL BATTERIES 3.7.1.2 HEAT STAGES Install batteries at this time. For instructions, see BAT- Set this to the number of non-compressor driven heat TERY INSTALLATION. stages to use for temperature control by this system. 3.7. INSTALLER SETUP 3.7.1.3 COMPRESSOR STAGES (COOL/HEAT PUMP Configuration items are selected from the Installer Set up STAGES) TYPICAL INSTALLER SETUP: MULTI-STAGE FURNACE HEAT Menu. They are stored in non-volatile RAM, and will be Set the number of compressor driven s

Summary of the content on the page No. 9

3.6. INSTALL BATTERIES 3.7.1.2 HEAT STAGES Install batteries at this time. For instructions, see BAT- Set this to the number of non-compressor driven heat TERY INSTALLATION. stages to use for temperature control by this system. 3.7. INSTALLER SETUP 3.7.1.3 COMPRESSOR STAGES (COOL/HEAT PUMP Configuration items are selected from the Installer Set up STAGES) TYPICAL INSTALLER SETUP: MULTI-STAGE FURNACE HEAT Menu. They are stored in non-volatile RAM, and will be Set the number of compressor driven s

Summary of the content on the page No. 10

3.7.1.10 SWING 2 3.7.2 INSTALLER SETUP MENU WITH FURNACE SYS- 16 Outdoor Sensor 4.1.3 DEFAULT PROGRAM ● This value is similar to the Swing 1, but it controls the TEM TYPE SELECTED: (future) NA/ON/OFF NA/OFF As supplied from the factory, the following ENERGY temperature variation the system allows above and below Menu 17 Internal Temp Sensor ON / OFF ON STAR approved program will be used for temperature Swing 1’s lower limit before calling for a second stage. Item Display Selections Default 18 Re

Summary of the content on the page No. 11

3.7.1.10 SWING 2 3.7.2 INSTALLER SETUP MENU WITH FURNACE SYS- 16 Outdoor Sensor 4.1.3 DEFAULT PROGRAM ● This value is similar to the Swing 1, but it controls the TEM TYPE SELECTED: (future) NA/ON/OFF NA/OFF As supplied from the factory, the following ENERGY temperature variation the system allows above and below Menu 17 Internal Temp Sensor ON / OFF ON STAR approved program will be used for temperature Swing 1’s lower limit before calling for a second stage. Item Display Selections Default 18 Re

Summary of the content on the page No. 12

required. Heating and cooling set temperatures may not button is pressed again, or if no other keys are pressed 4.2.4 TEMPERATURE DISPLAY FORMAT (F/C DISPLAY) grammed for. A general rule of thumb is to assume that be adjusted until heating or cooling is necessary, or one for 20 seconds. Temperature may be displayed in Fahrenheit or Celsius the fan will run at 1/3 duty cycle. A 90 day filter will then of these modes is manually selected by pressing and with this option. be good for 90*24/3=720 ho

Summary of the content on the page No. 13

required. Heating and cooling set temperatures may not button is pressed again, or if no other keys are pressed 4.2.4 TEMPERATURE DISPLAY FORMAT (F/C DISPLAY) grammed for. A general rule of thumb is to assume that be adjusted until heating or cooling is necessary, or one for 20 seconds. Temperature may be displayed in Fahrenheit or Celsius the fan will run at 1/3 duty cycle. A 90 day filter will then of these modes is manually selected by pressing and with this option. be good for 90*24/3=720 ho

Summary of the content on the page No. 14

● Today’s cumulative heating time ing the settings for that day. ● ● 4.3.3 VACATION HOLD Today’s cumulative cooling time Rotate the dial back to RUN to and accept all current Pressing this button will write default values of all ● Use this feature to instruct the thermostat to hold a fixed Yesterdays cumulative heating time values and end the programming session. temperature programs and setup menus into the unit’s ● temperature for a period of from 1 to 30 days. Yesterdays cumulative cooling ti

Summary of the content on the page No. 15

● Today’s cumulative heating time ing the settings for that day. ● ● 4.3.3 VACATION HOLD Today’s cumulative cooling time Rotate the dial back to RUN to and accept all current Pressing this button will write default values of all ● Use this feature to instruct the thermostat to hold a fixed Yesterdays cumulative heating time values and end the programming session. temperature programs and setup menus into the unit’s ● temperature for a period of from 1 to 30 days. Yesterdays cumulative cooling ti

Summary of the content on the page No. 16

Stage one of a cooling system will be deactivated at the 4.4.4 COPY PROGRAMMING value of swing 1 below the temperature set point. PSP722E ● The COPY button allows you to easily copy temperature Stage two of a heating system will be activated at the or fan programs from any day, to any other day, to all value of (swing 1 + swing 2) below the temperature set 52026 weekdays, to both weekend days, or all days. The Copy point. The auxiliary heat indicator AUX HT will be visible function copies only t


Alternative user manuals
# User manual Category Download
1 Lux Products CAG111 User manual Thermostat 18
2 Lux Products DMH100 Series User manual Thermostat 22
3 Lux Products DMH100 User manual Thermostat 12
4 Lux Products EcoStat THC15a User manual Thermostat 119
5 Lux Products ECOSTAT TH10 User manual Thermostat 3
6 Lux Products hp2110 User manual Thermostat 13
7 Lux Products ELV4C User manual Thermostat 14
8 Lux Products ELV1/PSPLV510 User manual Thermostat 0
9 Lux Products DHP2120 User manual Thermostat 6
10 Lux Products LHP-750 User manual Thermostat 0
11 Lux Products DMH100 User manual Thermostat 11
12 Lux Products 3M-22 User manual Thermostat 3
13 Lux Products P621U User manual Thermostat 1
14 Lux Products PSD011WA User manual Thermostat 3
15 Lux Products PSD111 User manual Thermostat 28
16 Edelbrock 2116 User manual Thermostat 0
17 A&D MF-50 User manual Thermostat 8
18 A&D ML-50 User manual Thermostat 8
19 A&D MS-70 User manual Thermostat 15
20 Acu-Rite D1523 User manual Thermostat 2