Lux Products RS600 user manual

User manual for the device Lux Products RS600

Device: Lux Products RS600
Category: Thermostat
Manufacturer: Lux Products
Size: 0.98 MB
Added : 9/11/2014
Number of pages: 29
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Lux Products RS600. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Lux Products RS600.

For your convenience

If looking through the Lux Products RS600 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Lux Products RS600 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Lux Products RS600 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Lux Products RS600 User manual - Online PDF
Advertisement
« Page 1 of 29 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Lux Products RS600 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Lux Products RS600. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

Thermostat Value Series
RS4000, RS5000 and RS600
®
UNI-LINE PRODUCT KNOWLEDGE
© 2009 Invensys. All Rights Reserved.
The names, logos, and taglines identifying the products and services of Invensys are proprietary marks of Invensys
or its subsidiaries. All third party trademarks and service marks are the proprietary marks of their respective owners.

Summary of the content on the page No. 2

Subjects We Will Cover In This Session • Thermostat Products and Features ® • Robertshaw Value RS456 Series • Manufacturer Comparison • Installation and Set-Up • Powering Thermostat • Pop-Up Wizard • Password Protection • System Test Mode • Where to Find Information • Q&A

Summary of the content on the page No. 3

Thermostat Series – Product Overview ® • Robertshaw i2 Deluxe Series – Setup Wizard – Time of day zoning – Independent remote and outdoor sensor terminals • RS4000, RS5000, and RS6000 Value Series – Pop-up Configuration Wizard – Auto Changeover – Circulating Fan • RS2000 and RS3000 Economy Series – Adjustable Temperature Differential – Worry-Free Memory Retention – Low Temperature Freeze Protection – Filter Indicator

Summary of the content on the page No. 4

Nomenclature for RS Series Application 2 = Non-Programmable, Economy Series 0 = Standard Thermostat 3 = 5-2 Day Programmable, Economy Series Number of Cooling Stages 4 = Non-Programmable, Value Series 5 = 5-2 Day Programmable, Value Series Number of Heating Stages 6 = 7-Day Programmable, Value Series

Summary of the content on the page No. 5

® Robertshaw Value Series Thermostats • RS4000 Series; Non-programmable – RS4110 1 Heat / 1 Cool; Universal Application* – RS4220 2 Heat / 2 Cool; Universal Application* – RS4320 3 Heat / 2 Cool; Universal Application* • RS5000 Series; Programmable; (5-2 Day Schedule) – RS5110 1 Heat / 1 Cool; Universal Application* – RS5220 2 Heat / 2 Cool; Universal Application* • RS6000 Series; Programmable (7 Day Schedule) – RS6110 1 Heat / 1 Cool; Universal Application* – RS6220 2 Heat / 2 Cool; Universa

Summary of the content on the page No. 6

Features: RS4000, RS5000 & RS6000 Series • Pop-up Wizard • Engineered True Blue backlight display • Largest Temperature Display Character Size • Soft Touch Keys • Set-up Test Mode • Auto Changeover • Circulating Fan • Low Temperature Freeze Protection • High Temperature Protection • High / Low Temperature Limits • Easy Change Battery Access • California Title 24 Compliant • 5 Year Limited Warranty

Summary of the content on the page No. 7

RS4000, RS5000 And RS6000 Series Installation And Set-Up

Summary of the content on the page No. 8

Installation - Mounting

Summary of the content on the page No. 9

Wiring Diagram Including Heat Pump Switch

Summary of the content on the page No. 10

Poll Question #1 G terminal (Green) connects to: a) Fan relay b) Condenser c) Humidifier solenoid G W terminal (White) connects to: a) Emergency heat W b) First stage heating relay Y c) Fan relay Y terminal (Yellow) connects to: a) Heat contact b) Reversing Valve c) Cooling contact

Summary of the content on the page No. 11

Installation – Initial Set-up

Summary of the content on the page No. 12

Installation – Powering Thermostat ® • Robertshaw Value Series Thermostats may be powered by either – 24V AC or 2 (AA) Batteries • Thermostats with batteries will continue to function if 24V AC fails • Installing Batteries – Battery tray is a drawer in the thermostat body – Pinch both sides and pull tray out from bottom – Install two AA batteries – Follow polarity as shown on inside tray – Slide tray back into the body • Battery Charge mode has two levels : – Level 1: Low battery icon. Chang

Summary of the content on the page No. 13

Poll Question #2 ® Robertshaw Value Series Thermostats are powered by: A. 24 Volts AC or AA Batteries B. Line Voltage or AAA Batteries C. Line Voltage only D. Batteries only

Summary of the content on the page No. 14

Access to Pop-Up Wizard After Start up • Press the UP and DOWN buttons simultaneously for 3 seconds • Pop-Up Wizard will initiate

Summary of the content on the page No. 15

Pop-Up Wizard Configuration Chart Displayed Choice Default SCAL F ° or C ° F ° CLOC 12 or 24 hour 12 LITE 1=always on, 0=off 0 Set Differential, 0.5-3 F ° or 0.5-1.5 C ° 1 F ° DIFF nd DIF2* Set 2 Stage Differential, 1-6 F ° or 0.5-3 C ° 2 F ° nd DLY2* 2 stage time delay, 5-40 min 20 rd DLY3** 3 stage time delay, 5-40 min 20 AUTO Enable Auto change over, Y = Yes, N = No Y DEDB Deadband in Degree’s, 1 – 8 F ° 3 F ° HI Upper heating limit, 45-90 F ° 90 F ° Lower Cooling Limit, 45-90 F ° 45

Summary of the content on the page No. 16

Password Protection • Press UP and HEAT/COOL buttons simultaneously • Hold for 10 seconds • Use the UP and DOWN to enter the desired digit • Use the HEAT/COOL button to move to the next digit • The password will be saved after 10 seconds • A lock will appear in the: – Upper left hand corner for RS4000 series – Lower right hand corner for RS5000 and RS6000 series • Default passwords are the following: – RS4000 is 81 – RS5000 and RS6000 is 8115

Summary of the content on the page No. 17

System Test Mode • Press FAN and HEAT/COOL buttons simultaneously • Hold for 10 seconds • Press the HEAT/COOL button to turn on heat • Only FAN, HEAT/COOL and Start/Stop buttons are active nd • A second press will turn on 2 stage of heat (on multistage models) • Continuous pressing of HEAT/COOL button will turn on cooling • Short Cycle protection is not enabled. May damage equipment and should only be performed by certified HVAC technicians • Push START/STOP to exit test mode on RS5000 and RS6

Summary of the content on the page No. 18

Staging Parameters Single Stage Models Demand Conventional (Non – HP) Heat Pump (HP) First Stage Cool Y1 & G Y1 & G & O First Stage Heat W1 & G (note, G is Off for Gas, On for Electric) Y1 & G & B Multi Stage Models Demand Conventional (Non – HP) Heat Pump (HP) First Stage Cool Y1 & G Y1 & G & O Second Stage Cool Y1& Y2 & G Y1 & Y2 & G & O First Stage Heat W1 & G Y1 & G & B Second Stage Heat (2H/2C) W1 & W2 & G Y1 & W2 & G & B Second Stage Heat (3H/2C) W1 & W2 & G Y1 & W2 & G & B Third Stage Hea

Summary of the content on the page No. 19

Poll Question #3 What is activated when UP and DOWN buttons are pushed simultaneously for 10 seconds? A. Password Setup B. System Test Mode C. Pop-Up Wizard D. Auto changeover

Summary of the content on the page No. 20

RS456 Value Series – Manufacturer Comparison White- ® Features Robertshaw Honeywell Rodgers Braeburn Lux RS4000 / RS5000 TH5000 3000 DMH110 / DHP2120 Family Model or SKU RS6000 TH6000 1F80 series 5000 TX500E / HP2110 Auto Changeover Pop-Up Wizard Test Option High & Low Temp Limits Freeze & Heat Protection Universal Equipment Adjustable Compressor Short Cycle Circulating Fan nd Adjustable 2 Stage Delay


Alternative user manuals
# User manual Category Download
1 Lux Products CAG111 User manual Thermostat 18
2 Lux Products DMH100 Series User manual Thermostat 22
3 Lux Products DMH100 User manual Thermostat 12
4 Lux Products EcoStat THC15a User manual Thermostat 119
5 Lux Products ECOSTAT TH10 User manual Thermostat 3
6 Lux Products hp2110 User manual Thermostat 13
7 Lux Products ELV4C User manual Thermostat 14
8 Lux Products ELV1/PSPLV510 User manual Thermostat 0
9 Lux Products DHP2120 User manual Thermostat 6
10 Lux Products LHP-750 User manual Thermostat 0
11 Lux Products DMH100 User manual Thermostat 11
12 Lux Products 3M-22 User manual Thermostat 3
13 Lux Products P621U User manual Thermostat 1
14 Lux Products PSD011WA User manual Thermostat 3
15 Lux Products PSD111 User manual Thermostat 28
16 Edelbrock 2116 User manual Thermostat 0
17 A&D MF-50 User manual Thermostat 8
18 A&D ML-50 User manual Thermostat 8
19 A&D MS-70 User manual Thermostat 15
20 Acu-Rite D1523 User manual Thermostat 2