York YMA024 user manual

User manual for the device York YMA024

Device: York YMA024
Category: Heat Pump
Manufacturer: York
Size: 0.52 MB
Added : 9/25/2014
Number of pages: 24
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for York YMA024. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with York YMA024.

For your convenience

If looking through the York YMA024 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual York YMA024 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual York YMA024 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
York YMA024 User manual - Online PDF
Advertisement
« Page 1 of 24 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual York YMA024 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to York YMA024. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 18

036-21570-002 Rev. D (0605) HEATING PERFORMANCE DATA OUTDOOR UNIT MODEL NO. YMA03011 INDOOR COIL MODEL NO. G2FD030S17 AIR TEMP. AIR TEMP. ID CFM ENTERING ENTERING 800 1000 1200 OUTDOOR INDOOR MBTUH KW C.O.P. MBTUH KW C.O.P. MBTUH KW C.O.P. UNIT COIL 60 37.8 2.9 3.8 37.2 2.9 3.8 36.6 2.8 3.9 60 70 36.1 3.1 3.5 35.9 3.0 3.5 35.8 2.9 3.6 80 34.5 3.2 3.2 34.7 3.1 3.3 34.9 3.0 3.4 60 33.5 2.7 3.7 33.1 2.6 3.7 32.7 2.5 3.8 47 70 28.6 2.7 3.1 30.0 2.7 3.3 31.4 2.6 3.5 80 23.6 2.8 2.5 26.9 2.7 2.9

Summary of the content on the page No. 19

036-21570-002 Rev. D (0605) HEATING PERFORMANCE DATA OUTDOOR UNIT MODEL NO. YMA03611 INDOOR COIL MODEL NO. G2FD036S17 AIR TEMP. AIR TEMP. ID CFM ENTERING ENTERING 1000 1200 1400 OUTDOOR INDOOR MBTUH KW C.O.P. MBTUH KW C.O.P. MBTUH KW C.O.P. UNIT COIL 60 41.2 3.0 4.0 42.8 2.9 4.3 44.4 2.9 4.6 60 70 38.4 3.2 3.5 39.8 3.1 3.8 41.3 3.0 4.0 80 35.6 3.3 3.1 36.9 3.3 3.3 38.1 3.2 3.5 60 37.0 2.8 3.8 38.1 2.8 4.0 39.1 2.7 4.3 47 70 34.0 3.0 3.3 35.2 2.9 3.5 36.4 2.8 3.7 80 31.0 3.1 2.9 32.3 3.1 3.

Summary of the content on the page No. 20

036-21570-002 Rev. D (0605) HEATING PERFORMANCE DATA OUTDOOR UNIT MODEL NO. YMA04211 INDOOR COIL MODEL NO. G2FD048S21 AIR TEMP. AIR TEMP. ID CFM ENTERING ENTERING 1200 1400 1600 OUTDOOR INDOOR MBTUH KW C.O.P. MBTUH KW C.O.P. MBTUH KW C.O.P. UNIT COIL 60 49.8 3.6 4.1 50.8 3.4 4.4 51.9 3.3 4.6 60 70 47.2 3.9 3.6 48.2 3.7 3.8 49.2 3.6 4.0 80 44.7 4.2 3.1 45.7 4.1 3.3 46.6 3.9 3.5 60 43.7 3.3 3.9 44.5 3.2 4.1 45.3 3.1 4.3 47 70 41.3 3.6 3.3 42.0 3.5 3.5 42.7 3.4 3.7 80 38.9 4.0 2.9 39.5 3.8 3.

Summary of the content on the page No. 1

P
G
M
U
Y
P
L
T
P
A
CE
OM
H
E
S C
R
T
I
F
I A
E
R
I
R
Q
A
I
CA
A
S T
T
U
A
I
O
I
N
O
036-21570-002 Rev. D (0605)
DESCRIPTION
The YMA Series unit is the outdoor part of a versatile heat pump
system. It is designed to be custom matched with one of our
complete line of evaporator sections, each designed to serve a
specific function. Matching air handlers are available for upflow,
downflow, and horizontal left or right application to provide a
complete system. Electric heaters are available if requi

Summary of the content on the page No. 2

036-21570-002 Rev. D (0605) Physical and Electrical Data MODEL YMA02411 YMA03011 YMA03611 YMA04211 YMA04811 YMA06011 Unit Supply Voltage 208-230V, 1 φ, 60Hz 1 187 to 252 Normal Voltage Range Minimum Circuit Ampacity 14.3 18.1 21.9 32.6 34.7 39.0 2 25 30 35 50 60 60 Max. Overcurrent Device Amps Compressor Type Recip Recip Recip Scroll Scroll Scroll Rated Load 11.1 13.3 16.4 24.9 26.6 30 Compressor Amps Locked Rotor 60 68 78 115 150 150 Crankcase Heater Yes Yes Yes No No No Fan Motor Amps Rated

Summary of the content on the page No. 3

036-21570-002 Rev. D (0605) Additional R-22 Charge / TXV Size for Various Matched Systems Outdoor Unit YMA02411 YMA03011 YMA03611 YMA04211 YMA04811 YMA06011 Unit Orifice (s) 63 69 78 87 - 96 1,2 1TV0701 1TV0701 1TV0702 1TV0702 1TV0703 - Approved System Thermal Expansion Valve Factory R-22 Charge, lbs-oz 7 - 2 7 - 12 8 - 6 8 - 12 9 - 1 14 - 2 3 4 Orifice - Additional Charge, Oz Indoor Coil Coil Orifice G2FD030(S,H)17 65 63/(701) + 2 69/(701) + 0 - - - G2FD035(S,H)14 65 63/(701) + 2 69/(701) + 0

Summary of the content on the page No. 4

036-21570-002 Rev. D (0605) COOLING CAPACITY - With Air Handler Coils AIR HANDLER COOLING 1 UNIT COIL 2 RATED TOTAL SENSIBLE SEER SEER ELECTRIC MODEL MODEL MODEL W EER HEAT KW CFM CAPACITY CAPACITY W/O TXV W/ TXV 1 PH 12 SEER HP WITH N1AH / G2FD N1AHB08 2,5,8,10 17 G2FD030(S,H)17(T) 800 24.0 18.8 12.00 12.0010.90 YMA02411 N1AHB12 2,5,8,10 17 G2FD030(S,H)17(T) 800 24.0 18.8 12.00 12.0010.90 N1AHB08 2,5,8,10 17 G2FD030(S,H)17(T) 1000 30.0 23.0 12.00 12.0011.10 YMA03011 N1AHB12 2,5,8,10 17 G2FD03

Summary of the content on the page No. 5

036-21570-002 Rev. D (0605) COOLING CAPACITY - Upflow, Downflow & Horizontal Furnaces and Coils FURNACE** COOLING COIL UNIT MODEL CFM RANGE TOTAL SENSIBLE SEER W/O TXV SEER W/TXV MODEL WRATED CFM EER 1,2 (MIN.-MAX.) CAPACITY CAPACITY + TDR + TDR 14 G1FA036S14 800 24.2 19.1 12.00 12.00 11.00 17,21 G1FA036S17,21 800 24.0 18.8 12.00 12.00 10.90 17 G2FD030(S,H)17(T) 800 24.0 18.8 12.00 12.00 10.90 14 G2FD035(S,H)14(T) 800 24.0 18.8 12.00 12.00 10.90 600 YMA02411 17 G1NA036S17J 800 24.2 18.8 12.00

Summary of the content on the page No. 6

036-21570-002 Rev. D (0605) COOLING CAPACITY - With Variable Speed Furnaces COOLING UNIT VARIABLE SPEED COIL W 1 RATED TOTAL SENSIBLE SEER SEER/ MODEL FURNACE MODEL MODEL EER 2 CFM CAPACITY CAPACITY W/O TXV +TDR W/TXV +TDR 3 1 PH 12 SEER HP / P1DU / P1XD / P1XU - VARIABLE SPEED P*DUA12V G1FA036S14 14 750 24.4 18.5 13.00 13.00 11.95 P*DUA12V G2FD035(S,H)14(T) 14 750 24.2 18.5 13.00 13.00 11.90 P*DUB16V G1FA036S17 17 795 24.4 19.0 13.00 13.00 11.95 P*DUB16V G2FD030(S,H)17(T) 17 795 24.4 19.0 13

Summary of the content on the page No. 7

036-21570-002 Rev. D (0605) COOLING CAPACITY - With Variable Speed Furnaces (Continued) COOLING UNIT VARIABLE SPEED COIL W RATED TOTAL SENSIBLE SEER SEER/ 4 MODEL FURNACE MODEL MODEL EER 5 CFM CAPACITY CAPACITY W/O TXV +TDR W/TXV +TDR 6 1 PH 12 SEER HP / P1DU / P1XD / P1XU - VARIABLE SPEED P*DUC20V G1FA060S21(T) 21 1610 46.0 35.8 - 12.10 10.40 P*DUC20V G2FD060(S,H)24(T) 24 1610 46.0 35.8 - 12.10 10.40 P*DUC20V G2FD061H24 24 1500 46.0 36.2 - 12.50 10.65 P1XUC16V G1FA060S21(T) 21 1600 46.0 3

Summary of the content on the page No. 8

036-21570-002 Rev. D (0605) HEATING PERFORMANCE - With Air Handler 2 3 ARI HEATING OUTDOOR TEMP 1 UNIT AIR COIL 47 17.00 HSPF -3 7 27 37 57 MODEL* HANDLER MODEL MBH COP KW MBH COP KW STD MBH KW MBH KW MBH KW MBH KW MBH KW 1 PH 12 SEER HP WITH N1AH/G2FD N1AHB08 G2FD030(S,H)17(T)24.03.462.0313.82.441.668.007.01.4110.41.5315.91.7317.91.7927.42.16 YMA02411 N1AHB12 G2FD030(S,H)17(T)24.03.462.0313.82.441.668.007.01.4110.41.5315.91.7317.91.7927.42.16 N1AHB08 G2FD030(S,H)17(T)30.03.282.6817.82.442.14

Summary of the content on the page No. 9

036-21570-002 Rev. D (0605) HEATING PERFORMANCE - Furnace Coils 2 3 ARI HEATING OUTDOOR TEMP 1 UNIT COIL 47°F17°FHSPF -3°F 7°F27°F37°F57°F MODEL* MODEL MBH COP KW MBH COP KW STD MBH KW MBH KW MBH KW MBH KW MBH KW G1FA036S14 24.0 3.50 2.01 13.8 2.46 1.64 8.00 7.1 1.41 10.5 1.53 16.0 1.72 18.0 1.79 27.5 2.15 G1FA036S17,21 24.0 3.46 2.03 13.8 2.44 1.66 8.00 7.0 1.41 10.4 1.53 15.9 1.73 17.9 1.79 27.4 2.16 G2FD030(S,H)17(T) 24.0 3.46 2.03 13.8 2.44 1.66 8.00 7.0 1.41 10.4 1.53 15.9 1.73 17.9 1.79

Summary of the content on the page No. 10

036-21570-002 Rev. D (0605) ACCESSORIES* SOUND POWER RATINGS* Hard Start Kit (024-31994-000, 024-31995-000) - Provides UNIT MODEL (dBA) increased starting torque for areas with low voltage. 024 71 TXV Kits - 1TV07 series thermal expansion valves precisely 030 75 meter refrigerant for optimum performance. 036 74 Dehumidistat (2HU16700124) - Provides increased dehu- 042 74 midification when matched with variable speed furnace or air 048 75 handler. 060 75 Heat Pump Risers - (526-35389-000, 526-353

Summary of the content on the page No. 11

036-21570-002 Rev. D (0605) COOLING PERFORMANCE DATA OUTDOOR UNIT MODEL NO. YMA02411 INDOOR COIL MODEL NO. G2FD030S17 ID CFM 600 800 1000 CONDENSER ENTERING AIR ID DB (°F) 80 80 75 80 80 80 80 75 80 80 80 80 75 80 80 TEMPERATURE ID WB (°F) 57 62 62 67 72 57 62 62 67 57 62 62 67 72 57 T.C. 22.5 25.1 25.1 28.2 30.0 25.0 26.4 26.4 29.2 30.1 27.5 27.6 27.8 30.1 30.3 65 S.C. 24.5 21.7 18.2 18.3 14.5 27.1 25.5 20.8 19.9 14.8 29.6 29.3 23.3 21.5 15.1 K.W. 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7

Summary of the content on the page No. 12

036-21570-002 Rev. D (0605) COOLING PERFORMANCE DATA OUTDOOR UNIT MODEL NO. YMA03011 INDOOR COIL MODEL NO. G2FD030S17 ID CFM 800 1000 1200 CONDENSER ENTERING AIR ID DB (°F) 80 80 75 80 80 80 80 75 80 80 80 80 75 80 80 TEMPERATURE ID WB (°F) 57 62 62 67 72 57 62 62 67 57 62 62 67 72 57 T.C. 29.1 32.6 32.6 35.6 35.2 31.4 33.1 35.3 35.0 34.4 33.7 33.7 38.0 34.4 33.7 65 S.C. 29.2 26.8 22.6 22.4 17.0 31.5 28.7 26.4 21.8 17.4 33.8 30.6 30.2 21.2 17.8 K.W. 2.1 2.1 2.1 2.1 2.1 2.1 2.1 2.1 2.1 2.1 2.1

Summary of the content on the page No. 13

036-21570-002 Rev. D (0605) COOLING PERFORMANCE DATA OUTDOOR UNIT MODEL NO. YMA03611 INDOOR COIL MODEL NO. G2FD036S17 ID CFM 1000 1200 1400 CONDENSER ENTERING AIR ID DB (°F) 80 80 75 80 80 80 80 75 80 80 80 80 75 80 80 TEMPERATURE ID WB (°F) 57 62 62 67 72 57 62 62 67 57 62 62 67 72 57 T.C. 34.8 38.3 37.7 41.6 40.7 37.8 39.6 39.0 42.0 40.2 40.8 40.9 40.4 42.5 39.8 65 S.C. 36.0 33.5 28.1 27.7 20.1 38.5 36.5 30.3 29.5 20.6 40.9 39.5 32.6 31.4 21.2 K.W. 2.4 2.4 2.4 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.

Summary of the content on the page No. 14

036-21570-002 Rev. D (0605) COOLING PERFORMANCE DATA OUTDOOR UNIT MODEL NO. YMA04211 INDOOR COIL MODEL NO. G1FA048S21 ID CFM 1200 1400 1600 CONDENSER ENTERING AIR ID DB (°F) 80 80 75 80 80 80 80 75 80 80 80 80 75 80 80 TEMPERATURE ID WB (°F) 57 62 62 67 72 57 62 62 67 57 62 62 67 72 57 T.C. 40.0 43.8 42.6 47.1 46.4 42.0 45.2 43.7 47.9 46.0 44.0 46.6 44.8 48.7 45.5 65 S.C. 42.3 38.6 32.9 32.6 23.9 44.2 42.0 35.4 34.5 24.4 46.2 45.4 37.9 36.4 24.9 K.W. 2.7 2.8 2.8 2.8 2.8 2.8 2.8 2.8 2.8 2.8 2.

Summary of the content on the page No. 15

036-21570-002 Rev. D (0605) COOLING PERFORMANCE DATA OUTDOOR UNIT MODEL NO. YMA04811 INDOOR COIL MODEL NO. G2FA060S24 ID CFM 1400 1600 1800 CONDENSER ENTERING AIR ID DB (°F) 80 80 75 80 80 80 80 75 80 80 80 80 75 80 80 TEMPERATURE ID WB (°F) 57 62 62 67 72 57 62 62 67 57 62 62 67 72 57 T.C. 42.8 45.7 45.8 50.3 57.2 44.6 47.0 47.0 51.5 57.3 46.3 48.3 48.1 52.8 57.5 65 S.C. 43.7 41.4 35.6 35.2 27.3 45.4 44.0 37.9 37.8 28.8 47.1 46.5 40.3 40.3 30.4 K.W. 3.1 3.1 3.1 3.2 3.2 3.1 3.1 3.1 3.2 3.2 3.

Summary of the content on the page No. 16

036-21570-002 Rev. D (0605) COOLING PERFORMANCE DATA OUTDOOR UNIT MODEL NO. YMA06011 INDOOR COIL MODEL NO. G2FA060S24 ID CFM 1600 1800 2000 CONDENSER ENTERING AIR ID DB (°F) 80 80 75 80 80 80 80 75 80 80 80 80 75 80 80 TEMPERATURE ID WB (°F) 57 62 62 67 72 57 62 62 67 57 62 62 67 72 57 T.C. 57.6 59.5 57.0 62.3 58.7 59.1 61.0 58.3 63.3 60.1 60.6 62.5 59.5 64.2 61.5 65 S.C. 56.2 53.7 44.2 44.1 30.5 57.7 56.6 46.8 46.4 31.9 59.3 59.5 49.4 48.8 33.3 K.W. 3.5 3.6 3.6 3.6 3.6 3.5 3.6 3.6 3.6 3.6 3.

Summary of the content on the page No. 17

036-21570-002 Rev. D (0605) HEATING PERFORMANCE DATA OUTDOOR UNIT MODEL NO. YMA02411 INDOOR COIL MODEL NO. G2FD030S17 AIR TEMP. AIR TEMP. ID CFM ENTERING ENTERING 600 800 1000 OUTDOOR INDOOR MBTUH KW C.O.P. MBTUH KW C.O.P. MBTUH KW C.O.P. UNIT COIL 60 27.2 2.2 3.5 27.3 2.1 3.7 27.4 2.0 3.9 60 70 26.8 2.3 3.4 27.1 2.2 3.5 27.4 2.1 3.7 80 26.4 2.4 3.2 26.9 2.3 3.4 27.3 2.3 3.5 60 24.9 2.0 3.6 24.6 2.0 3.7 24.4 1.9 3.8 47 70 23.7 2.1 3.3 24.0 2.0 3.5 24.3 2.0 3.6 80 22.4 2.2 3.0 23.4 2.1 3.2


Alternative user manuals
# User manual Category Download
1 York 060 User manual Heat Pump 12
2 York 161038-YUM-A-1205 User manual Heat Pump 3
3 York 2S User manual Heat Pump 3
4 York 8T User manual Heat Pump 94
5 York 3S User manual Heat Pump 2
6 York 090 User manual Heat Pump 1
7 York AHP18 THRU 60 User manual Heat Pump 1
8 York B1HP024 THRU 048 User manual Heat Pump 0
9 York AFFINITY YZB User manual Heat Pump 0
10 York BQ 060 User manual Heat Pump 1
11 York BQ 048 User manual Heat Pump 3
12 York B1HH018 User manual Heat Pump 1
13 York BP 036 User manual Heat Pump 4
14 York BQ 036 User manual Heat Pump 1
15 York E*BD-F018 THRU 060 User manual Heat Pump 2
16 Edelbrock 15005 User manual Heat Pump 0
17 A.O. Smith AH User manual Heat Pump 2
18 ACS 882.00217.00 User manual Heat Pump 1
19 A.O. Smith AHD 290 User manual Heat Pump 3
20 AC International SELF-PRIMING CENTRIFUGAL PUMPS User manual Heat Pump 5