Subaru Robin Power Products RGV6100 user manual

User manual for the device Subaru Robin Power Products RGV6100

Device: Subaru Robin Power Products RGV6100
Category: Portable Generator
Manufacturer: Subaru Robin Power Products
Size: 1.99 MB
Added : 9/30/2014
Number of pages: 82
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Subaru Robin Power Products RGV6100. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Subaru Robin Power Products RGV6100.

For your convenience

If looking through the Subaru Robin Power Products RGV6100 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Subaru Robin Power Products RGV6100 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Subaru Robin Power Products RGV6100 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Subaru Robin Power Products RGV6100 User manual - Online PDF
Advertisement
« Page 1 of 82 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Subaru Robin Power Products RGV6100 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Subaru Robin Power Products RGV6100. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

SERVICE
MANUAL
Models
RGV2800, RGV4100,
RGV6100
Generators
PUB-GS1277
Rev. 1/04

Summary of the content on the page No. 2

CONTENTS Section Title Page 1. SPECIFICATIONS ....................................................................................................... 1 2. PERFOMANCE CURVES ........................................................................................... 3 3. FEATURES.........................................................................................................

Summary of the content on the page No. 3

Section Title Page 9-4 STATOR .............................................................................................................. 33 9-5 ROTOR ASSEMBLY ........................................................................................... 34 9-6 CONDENSER ..................................................................................................... 34 9-7 DI

Summary of the content on the page No. 4

1. SPECIFICATIONS - 1 - M0 odel R0 GV280 RGV410 Type Brushless, Self Exciting, 2-Pole, Single Phase Frequency 60 Hz MW aximum Output2W 800 4100 ACRW ated Output 2W 300 3600 1A 20V 1V 9.2 1A 20 30.0 Rated Voltage Current 1A 20V/240V1V 9.2A/9.6 1A 20V/240 30.0A/15.0 Power Factor 1.0 DC Output 12 V-8.3 A (100 W) Voltage Regulator Condenser Type Type Air-Cooled 4-Cycle, Overhead Valve Gasoline Engine MD odel ED H17-2 EH25-2 3 3 Dm isplacement 172 c(m 10.50 cu. in.) 251 c (15.32 cu. in.) Rm ated Outp

Summary of the content on the page No. 5

- 2 - M0 odel RGV610 Type Brushless, Self Exciting, 2-Pole, Single Phase Fz requency 60 H MW aximum Output 5800 AC RW ated Output 4800 Rated Voltage 1A 20V/240V 40A/20 Current P0 ower Factor 1. D) C Output 12 V-8.3 A (100 W Ve oltage Regulator Condenser Typ Type Air-Cooled 4-Cycle, Overhead Valve Gasoline Engine MD odel EH34 3 Dm isplacement 338 c (20.63 cu. in.) Rm ated Output 8.0 HP / 3600 rp Fe uel Automobile Gasolin F) uel Tank Capacity 5.67 U.S. gal. (21.5 liters Rated Coutinuous Operation

Summary of the content on the page No. 6

2. PERFOMANCE CURVES ( ) Hz 63 Hz 62 61 60 ( ) V 250 ( ) 125 240 230V/115V ( ) 120 230 ( ) 115 220 ( ) 110 0 1/2 4/4 Load Rated - 3 -

Summary of the content on the page No. 7

DC OUTPUT DC Voltage ................. 12 V DC Ampere ................ 8.3 A DC output ................... 100 W The voltage curve shown in the left indicates the characteristic of DC output when charging a battery. The voltage may be decreased by 20% when the resistance load is applied. NOTE : It is possible to use both DC and AC outputs simultaneously up to the rated output in total. - 4 -

Summary of the content on the page No. 8

3. FEATURES 3-1 BRUSHLESS ALTERNATOR Newly developed brushless alternator eliminates troublesome brush maintenance. 3-2 CONDENSER TYPE VOLTAGE REGULATOR A trouble free condenser type voltage regulator ensures a stable voltage under all working conditions. 3-3 OIL SENSOR Oil sensor automatically shuts off the engine whenever the oil level falls down below the lower limit to protect the engine from seizure. 3-4 QUIET OPERATION Robin RGV series generator delivers a quiet operation with : * A large

Summary of the content on the page No. 9

3-9 MINIMAL MAINTENANCE * A brushless alternator release the operator from periodical brush maintenance. * A trouble free condenser type voltage regulator. * A drip-proof alternator design. * No-fuse circuit breakers. * An electronic pointless ignition system. * A dust-proof cyclone air cleaner. 3-10 LONG-LIFE DURABILITY The heavy-duty 4 stroke Robin Rro OHV engine and virtually maintenance-free brushless alternator ensure greater durability with : * A brushless alternator with a condenser volta

Summary of the content on the page No. 10

4. GENERAL DESCRIPTION 4-1 EXTERNAL VIEW FUEL GAUGE TANK CAP VOLTMETER ENGINE SWITCH FULL POWER SWITCH CHOKE KNOB AC RECEPTACLE AIR CLEANER EARTH TERMINAL DC OUTPUT TERMINAL RECOIL STARTER IDEL CONTROL SWITCH DC CIRCUIT BREAKER NO-FUSE OIL SENSOR BREAKER SPARK PLUG ENGINE EMISSION LABEL MUFFLER OIL DRAIN PLUG OILGAUGE (OIL FILLER) - 7 -

Summary of the content on the page No. 11

TEST RESET 4-2 CONTROL PANEL * RGV2800 : U.S.A., 60Hz-120V [NEMA RECEPTACLE] AC OUTPUT V METER ENGINE SWITCH ON AC MAX 20A ON OFF DC 12V-8.3A OFF BATTERY CHARGE ONLY DC OUTPUT DC BREAKER AC BREAKER * RGV4100 : U.S.A., 60Hz-120V/240V [NEMA RECEPTACLE] AC 120V FULL POWER SWITCH AC 120V / 240V V METER ENGINE SWITCH 120V ON 120V 240V OFF RESET TEST IDEL CONTROL ON 30A ON 20A 125V AC MAX 20A AC MAX 30A AC MAX 20A OFF ON OFF OFF DC 12V-8.3A BATTERY CHARGE ONLY DC OUTPUT DC BREAKER AC BREAKER - 8 -

Summary of the content on the page No. 12

* RGV6100 : U.S.A., 60Hz-120V/240V [NEMA RECEPTACLE] AC 120V FULL POWER SWITCH AC 120V / 240V V METER ENGINE SWITCH 120V 120V /240V ON RESET OFF TEST 30A 20A 150V ON IDEL CONTROL AC MAX 30A AC MAX 20A AC MAX 20A ON OFF ON OFF DC 12V-8.3A BATTERY CHARGE ONLY OFF DC OUTPUT DC BREAKER AC BREAKER 4-3 LOCATION of SERIAL NUMBER and SPECIFICATION NUMBER Serial number and specification number are stamped on the LABEL (MODEL NAME) stuck on the side wall of control box. NOTE : Always specify these

Summary of the content on the page No. 13

5. CONSTRUCTION AND FUNCTION 5-1 CONSTRUCTION END COVER BALL BEARING STATOR COMPLETE ROTOR COMPLETE REAR COVER STATOR COVER CRANKSHAFT MOUNT RUBBER THROUGH BOLT COVER BOLT FRONT COVER Fig. 5-1 5-2 FUNCTION 5-2-1 STATOR The stator consists of a laminated silicon steel sheet core, a main coil and a condenser coil which are wound in the core slots. The condenser coil excites the rotor field coil which generates AC voltage in the main coil. Fig. 5-2 - 10 -

Summary of the content on the page No. 14

5-2-2 CONDENSER One or two condensers are installed in the con- trol box and are connected to the condenser coil of the stator. These condensers and condenser coil regulate the output voltage. Fig. 5-3 5-2-3 ROTOR The rotor consists of a laminated silicon steel sheet core and a field coil which is wound over the core. DC current in the field coil magnetizes the steel sheet core. Two permanent magnets are provided for the primary exciting action. Fig. 5-4 A diode rectifier and surge absorber is m

Summary of the content on the page No. 15

5-2-4 NO-FUSE BREAKER The no-fuse breaker protects the generator from getting damage by overloading or short circuit in the appliance. Table 5-1 shows the capacity of no-fuse breaker by each spec. and their object of protection. MN ODELSR PECIFICATIONN O-FUSE BREAKE OBJECT or PROTECTIO RGV28006A 0 Hz-120V 2e 0 Total output amperag RGV41006) 0 Hz-120 V/ 240V1e 5 A (2-Pole, 2-Element Total output amperag 2e 0 A (2-Pole, 2-Element) Total output amperag RGV6100 60 Hz-120 V/ 240V 3e 0 A Output from 3

Summary of the content on the page No. 16

Se tyle Ae mperRg eceptaclAn C plu Descriptio GFCI (Ground Fault Circuit Interrupter) uA p to 20ANP EMA 5-20 NEMA 5-20 Receptacle, duplex (REC1) Locking Receptacle uR p to 20ANP EMA L14-20 NEMA L14-20 (REC2) Locking Receptacle uR p to 30ANP EMA L5-30 NEMA L5-30 (REC3) Table. 5-2 NOTE : If your generator has receptacles pecu- liar to your country, Table 5-2 does not apply. TWIST Caution : The duplex 120V receptacle is protected by a GFCI (Ground Fault Circuit Interrupter). GFCI shuts off the outp

Summary of the content on the page No. 17

5-2-8 CONNECTING TO DOMESTIC CIRCUITS (HOUSE WIRING) WARNING : All Robin generators are a neutral ungrounded type. If a generator is to be connected to residential or commercial power lines, such as a stand-by power source during power outage, all connections must be made by a licensed electrician. Failure in connection may result in death, personal injury, damage to generator, damage to appli- ances, damage to the building's wiring or fire. (a) When contnecting a Robin generator to a house wiri

Summary of the content on the page No. 18

Utility high line House circuit breaker Meter box XW Y 120V appliance 240V appliance 120V X WY appliance Transfer switch Generator ( ) W ()( ) X Y ( ) G 240V 4P- Receptacle Fig. 5-10 (c) Operating the generator. Set the full power switch to 120V/ 240V side. Turn the house AC breaker off before starting the generator. Start the generator and warm it up. Turn the house AC breaker on. Caution : Do not start the generator with electrical appliance (s) connected and with their switches on. Otherwise

Summary of the content on the page No. 19

5-3 GENERATOR OPERATION Fig. 5-11 5-3-1 GENERATION of NO-LOAD VOLTAGE (1) When the generator starts running, the permanent magnet built-in to the rotor generates 3 to 6V of AC voltage in the main coil and condenser coil wound on the stator. (2) As one or two condensers are connected to the condenser coil, the small voltage at the condenser coil generates a minute current a which flows through the condenser coil. At this time, a small flux is produced with which the magnetic force at the rotor’s

Summary of the content on the page No. 20

5-3-3 FULL POWER SWITCH (Dual Voltage Type) The full power switch is provided for the dual voltage type to take out the full rated power from one receptacle in each voltage. Fig. 5-12 Fig. 5-13 Switch LOWER VOLTAGE HIGHER VOLTAGE Position RECEPTACLE RECEPTACLE 1t 20/240 VHt alf of rated outpu Rated outpu Table. 5-3 Fig. 5-14 - 17 -


Alternative user manuals
# User manual Category Download
1 Subaru Robin Power Products Bannerman EC17D User manual Portable Generator 38
2 Subaru Robin Power Products EH63D User manual Portable Generator 24
3 Subaru Robin Power Products DY41 User manual Portable Generator 106
4 Subaru Robin Power Products DY30 User manual Portable Generator 18
5 Subaru Robin Power Products EH65D User manual Portable Generator 90
6 Subaru Robin Power Products EX30 User manual Portable Generator 17
7 Subaru Robin Power Products DY35 User manual Portable Generator 26
8 Subaru Robin Power Products EY33-2 User manual Portable Generator 13
9 Subaru Robin Power Products EY44-2 User manual Portable Generator 12
10 Subaru Robin Power Products EH64D User manual Portable Generator 1
11 Subaru Robin Power Products EY15-3D User manual Portable Generator 118
12 Subaru Robin Power Products EH12-2, EH17-2, EH25-2 User manual Portable Generator 800
13 Subaru Robin Power Products RGX2900 User manual Portable Generator 6
14 Subaru Robin Power Products EY20-3D User manual Portable Generator 785
15 Subaru Robin Power Products PUB-GP6050 User manual Portable Generator 0
16 ACDelco AC-G0005 User manual Portable Generator 1
17 ACDelco AC-G0002 User manual Portable Generator 0
18 ACDelco AC-G0004 User manual Portable Generator 3
19 AEG 2.33 2 User manual Portable Generator 3
20 ACDelco AC-G0003 User manual Portable Generator 0