Subaru Robin Power Products SERVICE MANUAL RGV7500 user manual

User manual for the device Subaru Robin Power Products SERVICE MANUAL RGV7500

Device: Subaru Robin Power Products SERVICE MANUAL RGV7500
Category: Portable Generator
Manufacturer: Subaru Robin Power Products
Size: 2.94 MB
Added : 9/30/2014
Number of pages: 67
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Subaru Robin Power Products SERVICE MANUAL RGV7500. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Subaru Robin Power Products SERVICE MANUAL RGV7500.

For your convenience

If looking through the Subaru Robin Power Products SERVICE MANUAL RGV7500 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Subaru Robin Power Products SERVICE MANUAL RGV7500 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Subaru Robin Power Products SERVICE MANUAL RGV7500 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Subaru Robin Power Products SERVICE MANUAL RGV7500 User manual - Online PDF
Advertisement
« Page 1 of 67 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Subaru Robin Power Products SERVICE MANUAL RGV7500 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Subaru Robin Power Products SERVICE MANUAL RGV7500. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

SERVICE
MANUAL
Model
RGV7500
PlJB-GS1436
Rev. 05/00

Summary of the content on the page No. 2

Section Title Page l.'SPECIFICATIONS ....................................................................................................... 1 2 . PERFOMANCE CURVES ........................................................................................... 2 3 . FEATURES .................................................................................................................. 3 3-1 A.V.R. ALTERNATOR ....................................................................................

Summary of the content on the page No. 3

Sectior! Title . Page 9-4 STATOR .............................................................................................................. 30 9-5 ROTOR ASSEMBLY ........................................................................................... 30 9-6 BRUSH ................................................................................................................ 31 9-7 A.V.R. (AUTOMATIC VOLTAGE REGULATOR) .................................................. 31 9-8 IDLE C

Summary of the content on the page No. 4

1. SPECIFICATIONS Model RGV7500 Brush, Self Exciting, 2-Pole, Single Phase 60 Hz ~~ ~ ~ ~ Maximum Output 7300 W Rated Output 6000 W j: U Rated Voltage 120V1240V 50N25A Current Power Factor 1 .o I 12 V-8.3 A (1 00 W) I DC Output I I I Air-Cooled 4-Cycle, Overhead Valve Gasoline Engine I EH41 D I Model Displacement I Rated Output 9.5 HP I 3600 rpm I Fuel Automobile Gasoline I Fuel Tank Capacity 7.26 U.S. gal. (27.5 liters) Rated Coutinuous Operation I I

Summary of the content on the page No. 5

2. PERFOMANCE CURVES RGV7500 / 60 Hz (6.0 kVN240V) f Load Rated \ DC OUTPUT DC Voltage ................. 12 V DC Ampere ................ 8.3 A DC output ................... 100 W The voltage curve shown in the left indicates the characteristic of DC output when charging a battery. The voltage may be decreased by 20% when the resistance load is applied. NOTE : It is possible to use both DC and AC outputs simultaneously up to the rated output in total. - 2-

Summary of the content on the page No. 6

3. FEATURES 3-1 AVR ALTERNATOR Output votage becomes more stable due to AVR system. 3-2 OIL SENSOR Oil sensor automatically shuts off the engine whenever the oil level falls down below the lower limit to protect the engine from seizure. 3-3 QUIET OPERATION Robin RGV series generator delivers a quiet operation with : A quiet 4-stroke Robin Rro OHV engine. Extra large muffler and large air cleaner provide remakable quiet operation. 3-4 NO RADIO N

Summary of the content on the page No. 7

3-9 LONG-LIFE DURABILITY The heavy-duty 4 stroke Robin OHV engine : * Full rubber mount in a sturdy tubular frame. * A forged steel crankshaft supported by two main ball bearings. A pointless electronic ignition system. * A cast-iron cylinder liner. I \ - 4-

Summary of the content on the page No. 8

4. GENERAL DESCRIPTION 4-1 EXTERNAL VIEW FUEL GAUGE CONTROL PANEL AIR CLEANER RECOIL STARTER IL GAUGE (OIL FILLER) OIL DRAIN PLUG OIL SENSOR FUEL TANK CHOKE LEVER SPARK PLUG CAP OUTLET - 5-

Summary of the content on the page No. 9

4-2 CONTROL PANEL HOUR METER VOLTMETER PILOT LAMP :\.ET3i STARTER TYPE) \ :;FEY AKCLE \ \ I I I ’ DC OUTPUT SWITCH TERMINAL ENGINE SWITCH DC CIRCUIT BREAKER (RECOIL STARTER TYPE) 4-3 LOCATION of SERIAL NUMBER and SPECIFICATION NUMBER Serial number and specification number are stamped on the LABEL (MODEL NAME) stuck on the side wall of rear cover. I NOTE : Always specify these numbers when inquiring about the generator or ordering spare parts in order to

Summary of the content on the page No. 10

5. CONSTRUCTION AND FUNCTION 5-1 CONSTRUCTION STATOR. COMPLETE TROUGH Fig. 51 5-2 FUNCTION 5-2-1 STATOR The stator consists of a laminated silicon steel sheet core, a main coil and a condenser coil which are wound in the core slots. The condenser coil excites the rotor field coil which generates AC voltage in the main coil. 3 Fig. 5-2 - 7- MOUNT RUBBER BALL BEARING BOLT FRONT COVER

Summary of the content on the page No. 11

5-2-2 ROTOR The rotor consists of a laminated silicon steel sheet and a field coil which is wound over the core. core DC current in the field coil magnetizes the steel sheet core. Two permanent magnets are provided for the primary exciting action. Slip rings are provided on the rotor shaft to re- ceive DC exciting current from A.V.R.. Fig. 5-3 5-2-3 BRUSW BRUSH HOLDER An exciting current is supplied from the A.V.R to the rotor. The brushes are made of carbon and

Summary of the content on the page No. 12

5-2-5 IDLE CONTROL UNIT The idle control unit releases throttle valve when the applied load current exceeds 0'.04A. The two output wires from the main coils must go through the ZCT in the same direction. NOTE : It is normal that the engine speed goes up for a moment when you turn the key switch to "STOP" while the Auto Idle Switch is in "ON" position. I Fig. 5-6 5-2-6 NO-FUSE BREAKER The no-fuse breaker protects the generator from getting dama

Summary of the content on the page No. 13

Table. 5-2 1 Caution : The duplex 120V receptacle is protected by a GFCl (Ground Fault Circuit Interrupter). \ TWIST GFCl shuts off the output current from the duplex 120V receptacle when a ground fault occurs in the generator or the appliance. Please note that other receptacles are not pro- tected by GFCI. 1 Caution : To connect the appliance to locking receptacle, insert the plug into the re- ceptacle and turn it clockwise to lock. - 10-

Summary of the content on the page No. 14

5-2-9 GFCI RECEPTACLE After starting the engine, check the GFCI for'proper functioning by the following test procedure. Push blue TEST button, The red RESET button will pop out exposing the word TRIP. Power is now off at the outlets protected by the GFCI, indicating that the device is functioning properly. If TRIP dose not appear when testing, do not use the generator. Call a qualified electrician. To restore power, push RESET button. WARNING :

Summary of the content on the page No. 15

Utility high line House circuit breaker - v I I 120v I appliance - 240V I appliance I 120v I appliance ,A- I I " - I """"""""""""""""" = 4P- Receptacle Fjg. 5- 70 (b) i I A transfer switch must be installed to transfer the load from the commercial power source to the 1 generator. This switch is necessary to prevent accidents caused by the recovery from power outage. ' Use a transfer switch of the correct capacity. Install transfer switch

Summary of the content on the page No. 16

53 DESCRIPTION Of GENERATOR OPERATION 5-3-1 PRIMARY EXCITING ACTION When the generator is started, the permanent n magnet on the engine rotates to generator a volt- age in the exciting coil. This voltage is regulated FC by a diode in the A.V.R. to feed a current to the generator field coil. (FC). (See Fig. 5-11) The rotor is turned an electromagnet by that cur- EC i rent and rotates so that voltage are generated in the stator coils (main coi

Summary of the content on the page No. 17

5-3-3 FULL POWER SWITCH (Dual Voltage Type) The full power switch is provided for the dual voltage type to take out the full rated power from one receptacle in each voltage. 120/240v r--- 1 MC1 240v - - 1 t.- Fig. 5- 14 MC1 MC1 MC2 MC2 1 Fig. Fig. 5- 5- 15 15 - r 1 REC.~ HIGHER VOLTAGE Switch LOWER VOLTAGE Position RECEPTACLE RECEPTACLE MC1 120/240 V Half of rated output Rated output I RECB 1 I Table. 5-3 - - MC2 - Fig. 5- 16 - 14-

Summary of the content on the page No. 18

Two main coils are wound over stator core. Each main coil outputs half the rated power at the lower voltage (120V). These main coils are wound to be in the same phase. The full power switch reconnects these main coils in parallel or in series. Fig. 5-14 shows a circuit diagram. When the full power switch is set for single lower voltage indication 5-1 5 is a simplified (120V), the switch position is as indicated by the lower solid line in the

Summary of the content on the page No. 19

5-4 OIL SENSOR 541 DESCRIPTION The oil sensor mainly functions to detect posi- tion of the surface of engine oil in the crankcase of engines for general use and to stop the en- gine automatically when the oil level goes down below the lower limit specified. This prevents sei- zure of engine from occurring due to insufficient amount of oil in the crankcase. OIL SENSOR Since the sensor has been designed to.consume a part of power supplied to the igniter to ener- gize it

Summary of the content on the page No. 20

[Judgement of oil level] When sufficient oil is in the crankcase, both of inner and outer electrodes are immersed in the oil through which current flows across the electrodes. The sensor judges that oil in the crankcase is sufficient. When oil level goes down and the inner electrode is exposed to the air due to consumption of oil, no current flow between the electrodes as air is considered to be electrically nonconductive. The sensor in


Alternative user manuals
# User manual Category Download
1 Subaru Robin Power Products Bannerman EC17D User manual Portable Generator 38
2 Subaru Robin Power Products EH63D User manual Portable Generator 24
3 Subaru Robin Power Products DY41 User manual Portable Generator 106
4 Subaru Robin Power Products DY30 User manual Portable Generator 18
5 Subaru Robin Power Products EH65D User manual Portable Generator 90
6 Subaru Robin Power Products EX30 User manual Portable Generator 17
7 Subaru Robin Power Products DY35 User manual Portable Generator 26
8 Subaru Robin Power Products EY33-2 User manual Portable Generator 13
9 Subaru Robin Power Products EY44-2 User manual Portable Generator 12
10 Subaru Robin Power Products EH64D User manual Portable Generator 1
11 Subaru Robin Power Products EY15-3D User manual Portable Generator 118
12 Subaru Robin Power Products EH12-2, EH17-2, EH25-2 User manual Portable Generator 800
13 Subaru Robin Power Products RGX2900 User manual Portable Generator 6
14 Subaru Robin Power Products EY20-3D User manual Portable Generator 785
15 Subaru Robin Power Products PUB-GP6050 User manual Portable Generator 0
16 ACDelco AC-G0005 User manual Portable Generator 1
17 ACDelco AC-G0002 User manual Portable Generator 0
18 ACDelco AC-G0004 User manual Portable Generator 3
19 AEG 2.33 2 User manual Portable Generator 3
20 ACDelco AC-G0003 User manual Portable Generator 0