Bosch Appliances FPE-1000-CITY user manual

User manual for the device Bosch Appliances FPE-1000-CITY

Device: Bosch Appliances FPE-1000-CITY
Category: Washer/Dryer
Manufacturer: Bosch Appliances
Size: 1.15 MB
Added : 4/22/2014
Number of pages: 16
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Bosch Appliances FPE-1000-CITY. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Bosch Appliances FPE-1000-CITY.

For your convenience

If looking through the Bosch Appliances FPE-1000-CITY user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Bosch Appliances FPE-1000-CITY on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Bosch Appliances FPE-1000-CITY to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Bosch Appliances FPE-1000-CITY User manual - Online PDF
Advertisement
« Page 1 of 16 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Bosch Appliances FPE-1000-CITY but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Bosch Appliances FPE-1000-CITY. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

City Tie Plug-in Module
FPE-1000-CITY
en Installation Guide pt Manual de Instalação
es Guía de instalación th ค ม ู ือก าร ต ิดต ั้ง

Summary of the content on the page No. 2

Summary of the content on the page No. 3

FPE-1000-CITY 3 en Installation Guide 4 es Guía de instalación 7 pt Manual de Instalação 10 th ค ู ม ือก ารตดต ิ ง ั้ 13 Bosch Security Systems, Inc. F.01U.078.100 | 04 | 2011.11

Summary of the content on the page No. 4

4 en FPE-1000-CITY Notices Use these instructions to install the FPE-1000-CITY City Tie Plug-in Module in FPA-1000 Analog Addressable Fire Panels. 1. Install, test, and maintain the FPE-1000-CITY according to these instructions, NFPA 72, local codes, and the Authority Having Jurisdiction (AHJ). 2. Follow the procedures in this document to avoid personal injury and damage to the equipment. Failure to follow these procedures can cause the FPE-1000-CITY to operate improperly. Bosch is not respon

Summary of the content on the page No. 5

FPE-1000-CITY en 5 FPE-1000-CITY S1 = SUP S2 = ALM DIP Switches 123 123 Reverse Polarity Mode ON ON ON ON ON ON Local Energy OFF OFF OFF OFF OFF OFF Note: You may use different operation modes for the circuits. The DIP switch settings 1 to 3 for each switch (S1 and S2) must be set to the same position. Mounting 1. Bring the plug-in module into position with the horizontal terminal lettering facing the front side of the control panel. Slide the plug-in module carefully into position along the g

Summary of the content on the page No. 6

6 en FPE-1000-CITY Local Energy Mode The FPE-1000-CITY connects Local Energy signaling devices to the FPA-1000 fire panel for auxiliary service operation. Refer to the FPA-1000 Installation and Operation Guide for a listing of compatible Gamewell devices. Terminal ALM - | + Connects to Municipal Master Box SUP - | + Not used ALM- ALM+ SUP- SUP+ Figure 4 Local Energy Mode Specifications Circuit resistance 65Ω 2 2 Wire gauge 12 to 18 AWG (3.3 mm to 0.8 mm ) Operating temperature 32 °F to 120 °F (

Summary of the content on the page No. 7

FPE-1000-CITY es 7 Avisos Utilice estas instrucciones para instalar el Módulo Enchufable City Tie FPE-1000-CITY en Centrales de Incendios Analógicas Direccionables FPA-1000. 1. Instale, pruebe y mantenga el dispositivo FPE-1000-CITY según estas instrucciones, la norma NFPA 72, los códigos locales y la autoridad con jurisdicción (AHJ). 2. Siga los procedimientos de este documento para evitar daños personales y daños al equipo. Si no sigue estos procedimientos, es posible que la unidad FPE-1000

Summary of the content on the page No. 8

8 es FPE-1000-CITY FPE-1000-CITY S1 = SUP S2 = ALM Conmutadores DIP 123 123 Modo de polaridad inversa ON ON ON ON ON ON Energía local OFF OFF OFF OFF OFF OFF Nota: puede utilizar varios modos de funcionamiento para los circuitos. Los ajustes de los conmutador DIP (1 a 3) deben quedar en la misma posición en ambos conjuntos (S1 y S2). Montaje 1. Coloque el módulo enchufable en posición con la rotulación del terminal horizontal orientada hacia la parte frontal del panel de control. Deslice el mó

Summary of the content on the page No. 9

FPE-1000-CITY es 9 Modo de energía local El dispositivo FPE-1000-CITY conecta los dispositivos de señalización de energía local a la Central de Incendio FPA- 1000 para la operación de servicio auxiliar. Consulte la Guía de Instalación y Operación FPA-1000 para ver una lista de dispositivos Gamewell compatibles. Terminal ALM - | + Conecta a la caja maestra municipal SUP - | + Sin utilizar ALM- ALM+ SUP- SUP+ Figura 8 Modo de energía local Especificaciones Resistencia del circuito 65Ω 2 2 Sección

Summary of the content on the page No. 10

10 pt FPE-1000-CITY Avisos Utilize estas instruções para instalar o Módulo City Tie tipo Plug-in FPE-1000-CITY nos Painéis de Incêndio Endereçáveis Analógicos FPA-1000. 1. Instale, teste e mantenha o FPE-1000-CITY de acordo com estas instruções, a norma NFPA 72, os códigos locais e a autoridade com jurisdição. 2. Siga os procedimentos descritos neste documento para evitar danos pessoais e danos no equipamento. O não cumprimento destes procedimentos pode fazer com que o FPE-1000-CITY funcione

Summary of the content on the page No. 11

FPE-1000-CITY pt 11 FPE-1000-CITY S1 = SUP S2 = ALM Interruptores DIP 1 2 3 1 2 3 Modo de Polaridade Invertida ON ONONONONON Energia Local OFF OFF OFF OFF OFF OFF Nota: Pode-se utilizar diferentes modos de operação para os circuitos. As configurações dos interruptores DIP 1 a 3 para cada um dos interruptores (S1 e S2) devem ser para a mesma posição. Instalação 1. Coloque o módulo plug-in na posição correta, com o texto horizontal inscrito no terminal virado para o lado frontal do painel de c

Summary of the content on the page No. 12

12 pt FPE-1000-CITY Modo de Energia Local O FPE-1000-CITY conecta os dispositivos sinalizadores de Energia Local ao painel de incêndio FPA-1000 para operação de serviço auxiliar. Consulte o Manual de Instalação e Operação para obter uma lista dos dispositivos Gamewell compatíveis. Terminal ALM - | + Conecta a Master Box (Caixa Principal) Municipal SUP - | + Não utilizado ALM- ALM+ SUP- SUP+ Figura 12 Modo de Energia Local Especificações Resistência do circuito 65Ω 2 2 Bitola do cabo 12 a 18 A

Summary of the content on the page No. 13

FPE-1000-CITY th 13 หมายเหต ุ ใช ค  าแนะน ํ าเหล ํ าน เพ ้ี อต ่ื ิ ดตงโมด ้ั ู ลป ลกอ ั๊ ิน City Tie FPE-1000-CITY ในแผงควบค ุมอ ั คค ีภ ัยท สามาร ี่ ถ ระบ ุ ตาแหน ํ งได  แบ  บอะนาล ็อก FPA-1000 1. ตดต ิ ง ้ั ทดสอบ และบ าร ํ งร ุ ักษา FPE-1000-CITY ตามค ําแนะน าต ํ อไปน ี้ ค ื อ NFPA 72, กฎหมายในพ ื้นท ่ี และหน วย  งานท ีม ่ อ ี ํานาจทางกฎหมาย (AHJ) 2. ปฏ ิบ ัต ิ ตามข ันตอนในเอกสารน ้ ี้เพอป ื่  องก นอ ั นตรายก ั ั บตวบ ั คค ุ ลแ ละป  องก ันไม ให  อ ุปกรณ เส ี ยหาย การไม ปฏ ิบ ัต ิ

Summary of the content on the page No. 14

14 th FPE-1000-CITY คาอธ ํ บายส ิ ัญล ั กษณ  S1 สว ิตช 1  การตรวจสอบ (SUP) S2 สว ิตช 2  ส ั ญญาณเต ื อนอ ัคค ี ภ ัย (ALM) 1 การ ต ้ังค าสว ิตช  DIP ส ําหร ับโหมดสล ั บข ั้ ว 2 การ ต ั้งค าสว ิตช  DIP ส ําหร ับโห มดใชพล  ังงานในเคร อง ่ื FPE-1000-CITY S1 = SUP S2 = ALM สว ิตช DI  P 123123 โหม ด สล ั บข ั้ว ON ON ON ON ON ON พล ั งงานในเคร ื่ อง OFF OFF OFF OFF OFF OFF หมายเหตุ: ค ุณสามารถใช งานวงจรในโหมดการท างานอ ํ ื่ นไ ด  การต ั้งค าสว ิตช DIP  แบบท ี่ 1 ถ ึ ง 3 ส ําหร ับสว ิ ตชแต

Summary of the content on the page No. 15

FPE-1000-CITY th 15 หมาย เหต ุ ออกแบบข ้ึ นเพ ่อก ื ารเช ื่อมต อเข  าก ับวงจรส ล ั บข ัวของหน ้ วยรบส ั ั ญญาณของ ส ถาน ทางไกลท ี ี่ม อ ี ั ตราการท ํางานท ีเข ่  าก ัน ได  แผงข ั้วต อการต ั้งค  าเบ ื้องต น  - M ALM + ALM - | + ส ัญญาเ ต ื อนอ คค ั ี ภ ัย - SUP SUP - | + การ ต รวจสอ บ + ค าอธ ํ ิ บายสญล ั กษณ ั  ร ูป 15 โหมดสล ั บข ้ัว M สถ าน ีตรวจสอบ โหมดใ ชพล  งงานภายในระบบ ั FPE-1000-CITY เชอมต ื่ ออ ุปกรณ ส  งส ัญญาณท ี่ใช พล  ั งงานในพ ้ืนท ี่เข าก  ั บแ ผงคว บค ุมอ ั คค ีภ ั

Summary of the content on the page No. 16

Bosch Security Systems, Inc. 130 Perinton Parkway Fairport, NY 14450 USA www.boschsecurity.us © Bosch Security Systems, Inc., 2011


Alternative user manuals
# User manual Category Download
1 Bosch Appliances WTZ 1295C User manual Washer/Dryer 18
2 Bosch Appliances WTZ1500P User manual Washer/Dryer 3
3 Bosch Appliances WFMC530RUC User manual Washer/Dryer 1
4 Bosch Appliances WTZ 1295P User manual Washer/Dryer 2
5 Bosch Appliances WTZ1500 User manual Washer/Dryer 5
6 Bosch Appliances WTZ1500S User manual Washer/Dryer 0
7 Bosch Appliances WTZ1500C User manual Washer/Dryer 0
8 Bosch Appliances WFMC530SUC User manual Washer/Dryer 1
9 Bosch Appliances WFL 2090 User manual Washer/Dryer 22
10 Harman-Kardon TC600 User manual Washer/Dryer 54
11 Admiral 3RATW3005TQ User manual Washer/Dryer 29
12 Advantek Networks AWN-USB-11N2 User manual Washer/Dryer 3
13 AEG L76475FL User manual Washer/Dryer 283
14 AEG 52630 User manual Washer/Dryer 255
15 AEG LAVAMAT 12710 User manual Washer/Dryer 189