CPG FIRELARM 2500#2561255 user manual

User manual for the device CPG FIRELARM 2500#2561255

Device: CPG FIRELARM 2500#2561255
Category: Smoke Alarm
Manufacturer: CPG
Size: 0.71 MB
Added : 8/5/2014
Number of pages: 44
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for CPG FIRELARM 2500#2561255. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with CPG FIRELARM 2500#2561255.

For your convenience

If looking through the CPG FIRELARM 2500#2561255 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual CPG FIRELARM 2500#2561255 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual CPG FIRELARM 2500#2561255 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
CPG FIRELARM 2500#2561255 User manual - Online PDF
Advertisement
« Page 1 of 44 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual CPG FIRELARM 2500#2561255 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to CPG FIRELARM 2500#2561255. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1


OPERATING MANUAL

FIRELARM 2500

4 ZONE
FIRE ALARM CONTROL PANEL


CPG Signals
th
2519 4 Ave., P.O. Box 590, Moline, IL 61265
(800) 577-5758 / (309) 762-0731 / FAX (309) 762-8215
www.cpglifesafety.com CPG #2561255 Rev. A 0209

Summary of the content on the page No. 2

CPG #2561255 FIRELARM 2500 Operating Manual Warranty CPG products are covered by a limited warranty. See CPG’s warranty statement for more information (document #780-0762).

Summary of the content on the page No. 3

Contents CPG #2561255 FIRELARM 2500 Operating Manual Contents 1 Overview...............................................................................1-1 1.1 General description...................................................................................................................1-1 1.2 System features.........................................................................................................................1-1 1.3 Specifications ..............................

Summary of the content on the page No. 4

CPG #2561255 FIRELARM 2500 Operating Manual 4.1.1 B1 Strobe device......................................................................................................................4-1 4.1.2 B1 Temporal pattern ................................................................................................................4-1 4.1.3 Reverse polarity circuits configuration .....................................................................................4-2 4.1.4 Annunciator disconnect.

Summary of the content on the page No. 5

CPG #2561255 FIRELARM 2500 Operating Manual 1 Overview 1.1 General description The FIRELARM 2500 is an economical, conventional Fire Alarm Control Panel (FACP) with an extensive list of features. When installed with an appropriate battery backup supply, the FireLarm 2500 provides a complete fire alarm control system for most applications. Available accessories include liquid crystal display (LCD), zonal digital alarm communicator transmitter (ZDACT), remote annunciators, and NAC Style Z

Summary of the content on the page No. 6

CPG #2561255 FIRELARM 2500 Operating Manual 1.3 Specifications 1.3.1 Electrical specifications Primary (AC) power: 120VAC, 60 Hz, 1.5A max Accessory (battery) voltage 24VDC; (charging current, 1.0A) Control Unit Requirements: Standby current 110mA, 24VDC (not including auxiliary devices and modules)200mA, 24VDC (not including auxiliary devices Alarm current and modules) Output Ratings: 1 System alarm contacts SPDT, 2A, 30VDC, 0.6 power factor System trouble contacts SPDT, 2

Summary of the content on the page No. 7

CPG #2561255 FIRELARM 2500 Operating Manual • Size 18-½" x 14-¼" x 3-¾" • Finish Red. • Knockouts Combination ½" / ¾", 2 on each side, top and back. • Option Bezel trim for semi-flush mounting. 1.3.3 Service use: NFPA-72 • Local • Auxiliary (PPU) • Remote Station (PPU) • Central Station (PPU) • PPU - Protected Premise Unit. 1 1.3.4 Listings and approvals • UL Listed (S6521, Guide UOJZ) 2 • CSFM Listed (7165-0476:154) 3 4 5 A B C D E 1-3

Summary of the content on the page No. 8

CPG #2561255 FIRELARM 2500 Operating Manual 1 1-4 Contents

Summary of the content on the page No. 9

CPG #2561255 FIRELARM 2500 Operating Manual 2 Operation 2.1 Touchpad The touchpad provides user control over the operation of the panel. It is readily accessible when the cover is open. Figure 2-1. FireLarm 2500 Touchpad. 2 3 4 Primary Primary Function Description Function Resets all alarm circuits if condition has been corrected, removes power from initiating 5 device circuit and auxiliary power from smoke detectors for 7 seconds. Disables notification appliance circuit and troub

Summary of the content on the page No. 10

CPG #2561255 FIRELARM 2500 Operating Manual Secondary Secondary Function Description Function Deletes the value at the cursor location when entering numeric values. (DELETE) Numeric entry of 1. Numeric entry of 2. Numeric entry of 3. Numeric entry of 4. Numeric entry of 5. 1 Numeric entry of 6. Numeric entry of 7. Numeric entry of 8. 2 Numeric entry of 9. Numeric entry of 0. Confirm change

Summary of the content on the page No. 11

CPG #2561255 FIRELARM 2500 Operating Manual 2.3 Normal Standby Condition The AC LED indicator is on with all other LED’s off. The fire alarm system is constantly monitoring all circuits for alarm signals, faults and remote communication. The panel optional LCD will display SYSTEM NORMAL when the system is operating as normal. 2.4 Silence and reset operation. 2.4.1 Silencing a non-normal condition (buzzer or NAC) Press . Press again to silence NAC if buzzer was silenced fir

Summary of the content on the page No. 12

CPG #2561255 FIRELARM 2500 Operating Manual 2.5.3 NAC trouble / silence Notification appliance circuit: An increase of current to approximately 3.5mA when not in alarm or a decrease in current to approximately 1.5mA on the notification appliance circuit will result in the following: Operation of the bell trouble LED. Operation of all system trouble indications (section 2.5.11 System trouble). Trouble zone number and name is displayed on the optional LCD. A current in excess of 2

Summary of the content on the page No. 13

CPG #2561255 FIRELARM 2500 Operating Manual With the exception of the loss of the AC-ON LED and transfer of the auxiliary trouble relay contacts, none of the trouble indicators will operate on loss of AC unless an adequately charged battery is connected to the proper terminals. 2.5.8 Auxiliary power output conditions Loss of output of the auxiliary power will result in the following: Operation of the auxiliary power LED. Operation of all system trouble indications (see section 2.5.

Summary of the content on the page No. 14

CPG #2561255 FIRELARM 2500 Operating Manual 1 2 2-6 Contents

Summary of the content on the page No. 15

CPG #2561255 FIRELARM 2500 Operating Manual 3 Installation 3.1 Safety message to installers People's lives depend on your safe installation of our products. It is important to read, understand, and follow all instructions shipped with this product. The Facilities Engineer and the Safety Engineer should make selection of mounting location for this product, its controls, and routing of wire. Listed below are some other important safety instructions and precautions you should follo

Summary of the content on the page No. 16

CPG #2561255 FIRELARM 2500 Operating Manual 3.2.5 Requirements for Central Station Fire Alarm Systems • Connect both phone lines to the optional ZDACT and OPLCD and program the telephone numbers for the reporting station. • Set the AC trouble report delay from 6 to 12 hours. 3.3 Installing the cabinet (and optional bezel) Figure 3-1. Surface mounting dimensions Figure 3-2. Semi-flush mounting dimensions 1 2 3 1. The FIRELARM 2500 unit may be surface mounted or Figure 3-3. Trim be

Summary of the content on the page No. 17

CPG #2561255 FIRELARM 2500 Operating Manual 3.4 Wiring Refer to Figures 3-5 through 3-7 for wiring information. 1. Install all required conduits, external wiring. With the AC power turned off at the circuit breaker panel, connect the 120VAC hot (black), neutral (white) and ground (green) wire to the panel as shown on the power supply connection drawing (Figure 3-7). 2. If not already done, install the main board into the cabinet and connect the transformer secondary leads to connector

Summary of the content on the page No. 18

CPG #2561255 FIRELARM 2500 Operating Manual Table 3-1: Current Requirements. Module/Device Standby mA Alarm mA 2500 with LCD display 170 310* 2500 without LCD display 105 250 CAM (Class A module) 0 25 RALCD (Remote Annunciator) 95 115 ZDACT (Digital Alarm Communicator) 30 50 MBM module 30 15 (250 momentary) PAM-1 or PAM-2 Relay 15 15 *Includes one zone short circuit current. Table 3-2: Secondary Power Requirements. 1 NFPA-72 National Fire Alarm Code Standby Time Alarm Time

Summary of the content on the page No. 19

CPG #2561255 FIRELARM 2500 Operating Manual Figure 3-4. Motherboard. # !" % $ #

Summary of the content on the page No. 20

CPG #2561255 FIRELARM 2500 Operating Manual Figure 3-6. Device Wiring 1 2 3 3-6 Contents TRANSFORMER BATTERY ZONE 1 ZONE 2 SUPERVISORY REMOTE ANNUNCIATOR (SUPERVISED) (SUPERVISED) (SUPERVISED) (SUPERVISED) CONNECTOR CONNECTOR (2 MAX, 100mA PER UNIT) (SUPERVISED) 34 34 56 78 9 10 11 12 13 14 15 16 17 18 E (+) (+) (-) (-) (+) (+) (-) (-) D D* GND +24V EARTH P2 BATT (+) (-) TB1 TB4 (OPTIONAL) SECONDARY WINDING OF REMOTE ANNUNCIATOR TRANSFORMER 5.1K 5.1K POWER RATING 120VAC - 60 HZ TYPIC


Alternative user manuals
# User manual Category Download
1 Adobe CS3 User manual Smoke Alarm 1
2 ADT Security Services ADT-LCD40 User manual Smoke Alarm 6
3 ADT Security Services Safewatch Pro 2000 User manual Smoke Alarm 5
4 ADT Security Services SAVS20ADT-1 User manual Smoke Alarm 3
5 ADT Security Services Unimode 9600 User manual Smoke Alarm 7
6 ADT Security Services SAVS20ADTG User manual Smoke Alarm 4
7 Aico Ei166RC User manual Smoke Alarm 12
8 Aico Carbon Monoxide Alarm Ei 225EN User manual Smoke Alarm 40
9 Aico Ei161RC User manual Smoke Alarm 5
10 Aico Ei169RF User manual Smoke Alarm 1
11 Aico Ei168RC User manual Smoke Alarm 14
12 Aico Carbon Monoxide Alarms 260 Series User manual Smoke Alarm 0
13 Aico Carbon Monoxide Alarm Ei 220EN User manual Smoke Alarm 0
14 Aico Ei164RC User manual Smoke Alarm 5
15 Aico Ei176RF User manual Smoke Alarm 1