Honeywell HA40 user manual

User manual for the device Honeywell HA40

Device: Honeywell HA40
Category: Smoke Alarm
Manufacturer: Honeywell
Size: 2.02 MB
Added : 9/25/2013
Number of pages: 39
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Honeywell HA40. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Honeywell HA40.

For your convenience

If looking through the Honeywell HA40 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Honeywell HA40 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Honeywell HA40 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Honeywell HA40 User manual - Online PDF
Advertisement
« Page 1 of 39 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Honeywell HA40 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Honeywell HA40. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

HA40 4-Channel Controller
HA40 Display & Alarm Controller
Quad Channel
COMMON
STATUS
LEVEL
LED's
ALARMS
ALARM 1 KEYPAD
ALARM 2 CAL IN PROGRESS
FAULT ALARM
ALARM 3
Magnetic
Keypad
Alarm
Next Edit
Reset
(Keypad buttons
behind door)
Power = 100-240 V~, 50/60 Hz, .45 A
or 10-30 VDC @ 3 WATTS
S/N 90-
Classified to CSA C22.2 NO. 152 for combustibles
detection. Class I, DIV.2, Groups A,B,C,D
READ & UNDERSTAND MANUAL!
219995
Technical Manual
Version 1.04 and up

Summary of the content on the page No. 2

HA40 4-Channel Controller mA input only). Safety • This equipment is suitable for use in Class I, Division 2, Groups A,B,C and D or non-hazardous locations only. Warning • EXPLOSION HAZARD- SUBSTITUTION OF COMPONENTS MAY Read and understand contents of this manual prior to operation. IMPAIR SUITABILITY FOR CLASS I, DIVISION 2. Failure to do so could result in serious injury or death. • EXPLOSION HAZARD- DO NOT REPLACE FUSE UNLESS POWER IMPORTANT SAFETY HAS BEEN SWITCHED OFF OR THE AREA

Summary of the content on the page No. 3

HA40 4-Channel Controller Table of Contents Safety ���������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������� i 1 General Description 1 General Description ���������������������������������������������������������������������������������������������������������������������������������������������������������� 1-2 11 Data Displa � y Screens ��������������������������������

Summary of the content on the page No. 4

HA40 4-Channel Controller 2 Operation 2 Operation ��������������������������������������������������������������������������������������������������������������������������������������������������������������������������� 2-2 2�1 Setup Menu Configuration �������������������������������������������������������������������������������������������������������������������������������������� 2-2 22 Changing Men � u Variables Using the Keypad �����������������������������������������������������������

Summary of the content on the page No. 5

HA40 4-Channel Controller 3 Motherboard Interface PCB 3 Motherboard Interface PCB ��������������������������������������������������������������������������������������������������������������������������������������������� 3-2 3�1 Input / Output Optional PCB’s �������������������������������������������������������������������������������������������������������������������������������� 3-3 3.1.2 Optional Analog Input PCB .........................................................................

Summary of the content on the page No. 6

HA40 4-Channel Controller 1 General Description HA40 Technical Manual 1-1 Revision 1 (08/08)

Summary of the content on the page No. 7

HA40 4-Channel Controller 1 General Description HA40 Display & Alarm Controller Quad Channel The Honeywell Analytics HA40 Quad Channel Controller is designed COMMON STATUS LEVEL LED's ALARMS to display, and control alarm event switching for four inputs. Inputs ALARM 1 KEYPAD ALARM 2 CAL IN PROGRESS are typically voltage or 4-20mA current from transmitters, monitors or ALARM 3 FAULT ALARM other analog output devices. The HA40 is equipped with a Fault and Magnetic Keypad Alarm Next Edit thre

Summary of the content on the page No. 8

HA40 4-Channel Controller 1�1 Data Display Screens 1�3 Specifications The HA40 Controller offers three modes for displaying monitored data, 1�3�1 Power Supply Requirements shown in Figure 1-4. The HA40 is equipped with an integral 15 watt universal AC input / 24 VDC output switching power supply. Standard HA40 AC power requirements are 100-240 VAC 50/60 Hz @ .45 amp max (including inrush) and 20 watts steady state, applied to TB5 on the motherboard. If AC power is not available, the HA40 m

Summary of the content on the page No. 9

HA40 4-Channel Controller The basic HA40 consumes only 1.5 watts of 10-30 VDC from the 13 � 2 Rela � ys integral power supply. Two mechanical (dry contact) Common Form C relays are standard and Optional features, and external devices such as remote transmitters, may be mapped to various alarm events as described in Section 2.3.1. increase power consumption as described below: HA40’s may also be equipped with optional solid-state common Form A relays (see Section 5 - Specifications for detai

Summary of the content on the page No. 10

HA40 4-Channel Controller 13 � 6 Housings / Installation Categories � 1�3�6 Housings / Installation Categories *NEMA 4X wall mount. DIV 2 Groups A,B,C,D; Category II and • • *NEMA 4X wall mount. DIV 2 Groups A,B,C,D; Category II and pollution degree 3; NEMA 4X; IP66*NEMA 7 wall mount for DIV pollution degree 3; NEMA 4X; IP66 1 & 2 Groups B,C,D; includes • o-ring in door to satisfy NEMA 4 • *NEMA 7 wall mount for DIV 1 & 2 Groups B,C,D; includes rating.*Includes standard non-intrusive magnetic

Summary of the content on the page No. 11

HA40 4-Channel Controller 2 Operation HA40 Technical Manual 2-1 Revision 1 (07/08)

Summary of the content on the page No. 12

HA40 4-Channel Controller 2 Operation The HA40’s graphic LCD displays monitored data. The 5-button keypad and the display serve as the system’s operator interface. All HA40 configuration variables are entered using this operator interface through SETUP menus accessed by pressing Edit from either data screen. This Setup mode may be exited manually by pressing Next, or automatically when no keys are pressed for 5 minutes. Alarm relays and front panel alarm LED indicators remain active du

Summary of the content on the page No. 13

HA40 4-Channel Controller 22 � �1 Setup Configuration Menus 2�2 Changing Menu Variables Using the The SETUP menu (shown in the middle of Figure 2-16 and in Figure Keypad 2-17) is accessed by pressing Edit when any data display is present. Magnetic This is the entry-level screen to all Channel, System and Security Keypad Alarm Next Edit Cal Reset (Keypad buttons menus. It also shows the firmware version operating in the HA40. behind door) Use the up/down arrow keys to move the pointer to

Summary of the content on the page No. 14

HA40 4-Channel Controller • Low Trip is set for NO to increase alarms or YES to decrease 22 � 3 F � ault / Alarm 1 / Alarm 2 / Alarm 3 Set-Up Menus alarms to determine if the alarm activates upon exceeding or Alarm 1, 2 and 3 have identical menus. The only difference between falling below the set-point. each is that A1 front panel LED indicators are yellow while A2 and A3 • Latching determines either manual or automatic alarm reset are red. Typical applications often have A1 set at a WA

Summary of the content on the page No. 15

HA40 4-Channel Controller Name / Eunits ASCII Data Fields Turning Off Unused Channels The first two items in this menu are for entering the 10 character The Channel Active menu option asks if this channel is to be utilized. channel Name and engineering unit ASCII fields. Name should NO causes the controller to never process inputs applied to this describe the channel’s data in user terminology such as tag # or other channel and no alarms are tripped or data displayed. Inactive channels des

Summary of the content on the page No. 16

HA40 4-Channel Controller Use the following step-by-step procedure to perform ZERO and SPAN 22 � �5 Cal Setup Menu calibrations. The CAL SETUP feature supports pushbutton calibration of zero 1. To enter the CAL SETUP from any data display, press the dual and span values. This feature should only be utilized when there are purpose down arrow / CAL key then use the up/down arrow no other zero/span controls within the monitoring system since it is keys to select the channel to calibrate. ina

Summary of the content on the page No. 17

HA40 4-Channel Controller Unity Gain may be used at anytime to cancel incorrect calibrations 23 � �1 Standard / Optional Relay Setup Menus and start again. Unity means Offset = 0.00 and Gain = 1.00. The menu shown in Figure 2-8 allows configuring of both the standard Relay 1 & Relay 2 motherboard relays and the six optional relays on the 10-0222 discrete relay option PCB. Both standard and optional relays are programmed in this menu. Select the relay to be configured by pointing the arro

Summary of the content on the page No. 18

HA40 4-Channel Controller • Over Ride menu allows entering one of the 16 different alarms • Warm-Up Delay menu allows setting how long alarm relays that will trip this relay regardless of the Votes entries. There remain disabled after power is applied. are four alarms per channel and four channels and any one of • Cal Delay determines how long alarm relays are inhibited after these alarms may be used as the Over Ride. This feature is completing a calibration. useful when one channel’s a

Summary of the content on the page No. 19

HA40 4-Channel Controller 23 � 4 Analog Setup Men � u 2�35 Horn / Ac � knowledge Menu The system ANALOG SETUP menu allows setting the 12-bit A/D J2 on the motherboard (shown in Figure 3.2) is the driver output for (analog to digital) counts and the 10-bit D/A (digital to analog) counts part # 1000-1892 optional 100dB piezo. Fault, Alarm1, Alarm 2, & for each of the four channels. The live A/D counts value for the channel Alarm 3 menu options (shown in Figure 2-12) allow programming of selec

Summary of the content on the page No. 20

HA40 4-Channel Controller The Relay 2 ACK menu item determines if standard relay 2 may be acknowledged by an Alarm Reset. ON causes an Alarm Reset to silence the horn even though an alarm condition remains active. Figure 2-12. Horn/Acknowledge Menu 24 HA40 System Security Men � u A 4-digit Pass Code entered and confirmed in this menu item locks all menus. Viewing of menus is not denied but attempts to edit variables result in the “Locked” message on the LCD. Authorized individuals locking


Alternative user manuals
# User manual Category Download
1 Honeywell DUCT-MOUNT AND OUTDOOR-MOUNT H7625B User manual Smoke Alarm 11
2 Honeywell DUCT-MOUNT AND OUTDOOR-MOUNT H7635B User manual Smoke Alarm 3
3 Honeywell DUCT-MOUNT AND OUTDOOR-MOUNT H7655B User manual Smoke Alarm 3
4 Honeywell DUCT-MOUNT AND OUTDOOR-MOUNT H7635C User manual Smoke Alarm 6
5 Honeywell 25/50ZS User manual Smoke Alarm 12
6 Honeywell 25/50ZST User manual Smoke Alarm 1
7 Honeywell EXCEL ADT-HRSI User manual Smoke Alarm 7
8 Honeywell ANN-RLY User manual Smoke Alarm 2
9 Honeywell 50ZST User manual Smoke Alarm 0
10 Honeywell C User manual Smoke Alarm 1
11 Honeywell C7015A User manual Smoke Alarm 14
12 Honeywell C7021F User manual Smoke Alarm 0
13 Honeywell C7021B User manual Smoke Alarm 1
14 Honeywell C7021D User manual Smoke Alarm 1
15 Honeywell C7021K User manual Smoke Alarm 0
16 Adobe CS3 User manual Smoke Alarm 1
17 ADT Security Services ADT-LCD40 User manual Smoke Alarm 6
18 ADT Security Services Safewatch Pro 2000 User manual Smoke Alarm 5
19 ADT Security Services SAVS20ADT-1 User manual Smoke Alarm 3
20 ADT Security Services Unimode 9600 User manual Smoke Alarm 7