SkyLink DIAL-ALERT AD-105 user manual

User manual for the device SkyLink DIAL-ALERT AD-105

Device: SkyLink DIAL-ALERT AD-105
Category: Medical Alarms
Manufacturer: SkyLink
Size: 0.36 MB
Added : 10/26/2013
Number of pages: 14
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for SkyLink DIAL-ALERT AD-105. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with SkyLink DIAL-ALERT AD-105.

For your convenience

If looking through the SkyLink DIAL-ALERT AD-105 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual SkyLink DIAL-ALERT AD-105 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual SkyLink DIAL-ALERT AD-105 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
SkyLink DIAL-ALERT AD-105 User manual - Online PDF
Advertisement
« Page 1 of 14 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual SkyLink DIAL-ALERT AD-105 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to SkyLink DIAL-ALERT AD-105. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

www.skylinkhome.com
Emergency Dialer
TM
DIAL-ALERT
MODEL: AD-105
If you would like to order Skylink’s products or have
difficulty getting them to work or download information
and user manual, please :
1. visit our FAQ section at www.skylinkhome.com, or
2. email us at support@skylinkhome.com, or
3. call our toll free at 1-800-304-1187 from Monday to
Friday, 9 am to 5 pm EST.
Fax (800) 286-1320
CUSTOMER SERVICE
17 Sheard Avenue, Brampton, Ontario, Canada L6Y 1J3
Tel : (800) 304-1187
Fax : (800) 2

Summary of the content on the page No. 2

SKYLINK TECHNOLOGIES INC. TABLE OF CONTENTS Your Guide to the PACKAGE CONTENTS............................................................................................4 OVERVIEW.....................................................................................................5-6 Emergency Dialer INSTALLATION..............................................................................................................7-9 TM LIGHTS AND SOUNDS....................................................

Summary of the content on the page No. 3

* * * # # C # A B PACKAGE CONTENTS OVERVIEW All materials required for installation are included with this package The AD-105 emergency dialer can call multiple phone numbers during an emergency situation and it will playback prerecorded messages. There are 2 operating modes you can set up in the AD-105 dialer. 1 Dial-Alert (AD-105) 1 Telephone Line SC-001 Mode - Works with SC-001 1 antenna (installed) 1 AC adapter You can setup the AD-105 to communicate with a control panel

Summary of the content on the page No. 4

OVERVIEW INSTALLATION Dial Alert AD-105 must work with the specific sensors listed below. Ensure only the The Dial-Alert is installed using the screws provided. We have also included listed sensors are used with the AD-105, otherwise, the communication between the double sided tape, to use for temporary installation while you are positioning sensors and the Dial Alert may not function properly. If you have a Skylink wireless the dialer. Once the dialer is positioned correctly, install it permane

Summary of the content on the page No. 5

INSTALLATION INSTALLATION Speaker On/Off Switch 2. Thread the telephone line through the top The speaker must be on during pro- hole in the back of the unit and plug it into gramming and recording the voice the "LINE" jack. If you want to have an message in order to use the playback answering machine on the same line as feature. For security purposes, the the dialer, thread the phone line through the speaker may be turned off after pro- bottom hole in the back of the unit and plug gramming to a

Summary of the content on the page No. 6

LIGHTS AND SOUNDS STANDARD PROGRAMMING There are a few programming steps you must perform before the dialer can Below is an explanation of the lights and sounds of the Dial-Alert operate. Please follow the instructions below to program these fields, including: LIGHTS - Selecting the Operation Mode ACPWR light on dialer is being powered by AC adapter. - Record voice messages ACPWR light off dialer is not receiving any AC power. - Phone numbers you wish to dial during emergency (up to 9 phone numb

Summary of the content on the page No. 7

STANDARD PROGRAMMING STANDARD PROGRAMMING 5. After recording the message, you will hear the recorded message. After the RECORD A VOICE MESSAGE message playback, it will quit from programming and return to standby mode. 6. The display still shows “not rEAdy” because no phone number has been You must record a message and program at least one phone number in programmed. order for the Dial Alert to work. MESSAGE PLAYBACK The voice recording procedure is different between the 2 operating modes, SC

Summary of the content on the page No. 8

STANDARD PROGRAMMING STANDARD PROGRAMMING 1. Enter the current password (factory default password is 0000), then Do not program the phone number to police or fire dept directly into your Dial-Alert press [PROG], display will show [P] meaning you are now in programming unless you have checked with your local authorities. Please also inform all the mode. recipients that their phone numbers have been programmed into your dialer, so 2. Enter [5] which represents programming a device. You will see t

Summary of the content on the page No. 9

OPERATIONS OPERATIONS SC-001 Mode 1. To stop the call from calling a specific phone number. Since there is a redial count and regardless of whether the call is picked When the display shows “rEAdy”, that means the unit is in standby mode. up or not, it will redial based on the redial counts. If the redial count is set It will dial when it receives a panic signal from the alarm panel, or its own to 3 times, that means it will call that phone number 3 times. If the panic button is pressed. recip

Summary of the content on the page No. 10

ADVANCED PROGRAMMING ADVANCED PROGRAMMING Changing Password Erase Programmed Panic Transmitters / Alarm Panels / Sensors Password is required for programming purposes. Factory default is 0000. You may erase the programmed wireless devices, panic transmitter, alarm To change the setting, follow the instructions below. panels and wireless sensors. You cannot erase a specific device, you must erase all the devices and then program the ones that you would like to keep. 1. Enter the current password

Summary of the content on the page No. 11

ADVANCED PROGRAMMING ADVANCED PROGRAMMING 1. Enter the current password (factory default password is 0000), then 3. Enter [1] to disable universal dial tone meaning a proper dial tone must press [PROG], display will show [P] meaning you are now in programming be presented before dialing, or [2] to enable universal dial tone, so the mode. Dial Alert will dial regardless of the dial tone. 2. Enter [8], display now shows [P8 1], the most right digit represents 4. If the new setting is accepted,

Summary of the content on the page No. 12

ADVANCED PROGRAMMING BATTERY MAINTENANCE The AD-105 Dial-Alert comes with 1 battery that at some point you may CONNECT THE DIAL-ALERT WITH YOUR EXISTING ALARM SYSTEM have to replace: You may connect your existing alarm system with the Dial-Alert so that the dialer will be triggered by your alarm system when it is activated. There are 2 ways you One 9 volt alkaline battery for the Dial-Alert can connect your dialer with your existing alarm system. 1. Connect the dialer with the alarm system Recom

Summary of the content on the page No. 13

ADDITIONAL ACCESSORIES ADDITIONAL ACCESSORIES Additional sensors and transmitters as well as add on accessories are available Temperature Sensor (TS-101A) to work with your Dial-Alert. - Monitors temperature of a specific area (i.e., greenhouse, horse farms, laboratory etc.) Security Control Panel (SC-001) - Activates Security Control Panel (SC-001) or - Four alarm modes (Day, Night, Away, Chime) Emergency Dialer (AD-105) when the tempera- - Four zones, each zone controls up to 6 ture of t

Summary of the content on the page No. 14

ADDITIONAL ACCESSORIES Audio Sensor (AS-101) - Detects alarm sound from existing security system alarm; sends signal to Dial-Alert. - Eliminates need for monitoring service. - 9V alkaline battery included Vibration Sensor (VS-101) - Activates Security Control Panel or Emergency Dialer when vibration is detected - Attach vibration sensor to valuables - 3V lithium battery included TM Garage Door Monitor Sensor (GS-101) - Place sensor on garage door - Activates Security Control Panel or Em


Alternative user manuals
# User manual Category Download
1 SkyLink ad-103 User manual Medical Alarms 0
2 SkyLink SA-001S User manual Medical Alarms 0
3 ADT Security Services Universal Zone Coder User manual Medical Alarms 8
4 ADT Security Services ADT-UZC-256 User manual Medical Alarms 3
5 AGFA HE/001132 User manual Medical Alarms 26
6 Aiphone 83873900 0602 E User manual Medical Alarms 7
7 Aiphone NHX NH-1SA-AC-BLU User manual Medical Alarms 7
8 Aiphone TL-2000 User manual Medical Alarms 0
9 Aiphone NHX NH-1SA-ACB-BLU User manual Medical Alarms 0
10 Aiphone TAR-3 User manual Medical Alarms 2
11 Barco NIO E-3620 User manual Medical Alarms 10
12 Barco NIO E-2620 User manual Medical Alarms 1
13 Bosch Appliances VJR-A3-SP User manual Medical Alarms 1
14 Carson Manufacturing Company, Inc.Horn System User manual Medical Alarms 0
15 Cisco Systems OL-10984-01 User manual Medical Alarms 0