Trane Engineered Smoke Control System for Tracer Summit user manual

User manual for the device Trane Engineered Smoke Control System for Tracer Summit

Device: Trane Engineered Smoke Control System for Tracer Summit
Category: Smoke Alarm
Manufacturer: Trane
Size: 5.75 MB
Added : 7/21/2013
Number of pages: 156
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Trane Engineered Smoke Control System for Tracer Summit. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Trane Engineered Smoke Control System for Tracer Summit.

For your convenience

If looking through the Trane Engineered Smoke Control System for Tracer Summit user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Trane Engineered Smoke Control System for Tracer Summit on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Trane Engineered Smoke Control System for Tracer Summit to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Trane Engineered Smoke Control System for Tracer Summit User manual - Online PDF
Advertisement
« Page 1 of 156 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Trane Engineered Smoke Control System for Tracer Summit but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Trane Engineered Smoke Control System for Tracer Summit. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

Applications
Guide
Engineered Smoke
Control System

for TRACER SUMMIT
BAS-APG001-EN

Summary of the content on the page No. 2

Summary of the content on the page No. 3

Applications Guide Engineered Smoke Control System ™ for TRACER SUMMIT BAS-APG001-EN September 2006

Summary of the content on the page No. 4

™ Applications Guide, Engineered Smoke Control System for Tracer Summit This guide and the information in it are the property of American Standard and may not be used or reproduced in whole or in part, without the written permission of American Standard. Trane, a business of American Standard, Inc., has a policy of continuous product and product data improvement and reserves the right to change design and specification without notice. Use of the software contained in this package is provided u

Summary of the content on the page No. 5

NOTICE: Warnings and Cautions appear at appropriate sections throughout this manual. Read these carefully: WARNING Indicates a potentially hazardous situation, which, if not avoided, could result in death or serious injury. CAUTION Indicates a potentially hazardous situation, which, if not avoided, may result in minor or moderate injury. It may also be used to alert against unsafe practices. CAUTION Indicates a situation that may result in equipment damage or property damage. The following fo

Summary of the content on the page No. 6

Summary of the content on the page No. 7

Contents Contents Chapter 1 Smoke control overview . . . . . . . . . . . . . . . . . . . . . 1 Methods of smoke control. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Compartmentation method. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Dilution method . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Pressurization method . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Airflow method

Summary of the content on the page No. 8

Contents Smoke control system equipment . . . . . . . . . . . . . . . . . . . . . . . . . . 23 Equipment supervision . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26 System testing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27 Automatic weekly self-testing. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27 Manual periodic testing. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27 Alarm re

Summary of the content on the page No. 9

Contents Circuit requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59 Wiring high-voltage power . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60 EMI/RFI considerations. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62 Checking the earth ground . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62 Wiring inputs and outputs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64 Inp

Summary of the content on the page No. 10

Contents Binary outputs. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 94 Analog outputs (UUKL nondedicated only) . . . . . . . . . . . . . . . . . . . 94 Analog output and universal input setup . . . . . . . . . . . . . . . . . . . . . . . . 94 Interpreting EX2 LEDs. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 96 Binary output LEDs. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 96 Status LED .

Summary of the content on the page No. 11

Contents Node . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 131 Binding types . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 131 Basic binding shapes and the hub/target system . . . . . . . . . . . . . 131 Designing bindings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 133 Appendix A References. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 141 BAS-APG001-EN v

Summary of the content on the page No. 12

Contents vi BAS-APG001-EN

Summary of the content on the page No. 13

Chapter 1 Smoke control overview Smoke is one of the major problems created by a fire. Smoke threatens life and property, both in the immediate location of the fire and in locations remote from the fire. The objectives of smoke control include: • Maintain reduced-risk escape route environments • Diminish smoke migration to other building spaces • Reduce property loss • Provide conditions that assist the fire service • Aid in post-fire smoke removal Smoke consists of airborne solid and liquid

Summary of the content on the page No. 14

Chapter 1 Smoke control overview Methods of smoke control Smoke control system designers use five methods to manage smoke. They use the methods individually or in combination. The specific methods used determine the standards of design analysis, performance criteria, acceptance tests, and routine tests. The methods of smoke control consist of: compartmentation, dilution, pressurization, air flow, and buoyancy. Compartmentation method The compartmentation method provides passive smoke protect

Summary of the content on the page No. 15

Methods of smoke control Figure 1: Sample pressure difference across a barrier Table 1 provides the National Fire Protection Association (NFPA) recommended minimum pressure difference between the high-pressure side and the low-pressure side. Table 1: Recommended minimum pressure difference Minimum pressure Ceiling height difference Building type (ft [m]) (In.w.c. [Pa]) Sprinklered Any 0.05 (12.4) Non-sprinklered 9 (2.7) 0.10 (24.9) Non-sprinklered 15 (4.6) 0.14 (34.8) Non-sprinklered 21 (6.4)

Summary of the content on the page No. 16

Chapter 1 Smoke control overview Table 2: Maximum allowable pressure differences across doors Door width (in. [m]) 32 (0.813) 36 (0.914) 40 (1.02) 44 (1.12) 46 (1.17) Door closer force Pressure difference (lb. [N]) (In.w.c. [Pa]) 6 (26.7) 0.45 (112.0) 0.40 (99.5) 0.37 (92.1) 0.34 (84.6) 0.31 (77.1) 8 (35.6) 0.41 (102.0) 0.37 (92.1) 0.34 (84.5) 0.31 (77.1) 0.28 (69.7) 10 (44.5) 0.37 (92.1) 0.34 (84.5) 0.30 (74.6) 0.28 (69.7) 0.26 (64.7) 12 (53.4) 0.34 (84.5) 0.30 (74.6) 0.27 (67.2) 0.25 (62.2

Summary of the content on the page No. 17

Applications of smoke control methods A disadvantage of the airflow method is that it supplies increased oxygen to a fire. Within buildings, the airflow method must be used with great caution. The airflow required to control a wastebasket fire has sufficient oxygen to support a fire 70 times larger than the wastebasket fire. The airflow method is best applied after fire suppression or in buildings with restricted fuel. For more information on airflow, oxygen, and combustion, refer to Hugge

Summary of the content on the page No. 18

Chapter 1 Smoke control overview Zoned smoke control cannot limit the spread of smoke within the smoke control zone. Consequently, occupants of the smoke control zone must evacuate as soon as possible after fire detection. Figure 3: Sample arrangements of smoke control zones + : Represents high-pressure zone – : Represents low-pressure zone When an HVAC system serves multiple floors (Figure 4 on page 7) and each floor is a separate zone, the following sequence provides smoke control: 1. In

Summary of the content on the page No. 19

Applications of smoke control methods Figure 4: Sample HVAC operation during smoke control Note: For simplicity, Figure 4 does not show the ducts on each floor or the penthouse equipment. When an HVAC system serves only one smoke control zone, the following sequence provides smoke control: 1. In the smoke control zone, the return/exhaust fan activates, the supply fan deactivates. 2. The return air damper closes, and the exhaust damper opens (optionally, the outside air damper closes). 3. In

Summary of the content on the page No. 20

Chapter 1 Smoke control overview If the technique employs modulated supply airflow, a fan provides at least minimum pressure when all stairwell access doors are open. Either a single-speed fan with modulating bypass dampers or a variable frequency drive varies the flow of air into the stairwell to compensate for pressure changes. If the technique employs over-pressure relief, a damper or fan relieves air to the outside to maintain constant pressure in the stairwell. The amount of air relie


Alternative user manuals
# User manual Category Download
1 Trane BAS-APG001-EN User manual Smoke Alarm 2
2 Adobe CS3 User manual Smoke Alarm 1
3 ADT Security Services ADT-LCD40 User manual Smoke Alarm 6
4 ADT Security Services Safewatch Pro 2000 User manual Smoke Alarm 5
5 ADT Security Services SAVS20ADT-1 User manual Smoke Alarm 3
6 ADT Security Services Unimode 9600 User manual Smoke Alarm 7
7 ADT Security Services SAVS20ADTG User manual Smoke Alarm 4
8 Aico Ei166RC User manual Smoke Alarm 12
9 Aico Carbon Monoxide Alarm Ei 225EN User manual Smoke Alarm 40
10 Aico Ei161RC User manual Smoke Alarm 5
11 Aico Ei169RF User manual Smoke Alarm 1
12 Aico Ei168RC User manual Smoke Alarm 14
13 Aico Carbon Monoxide Alarms 260 Series User manual Smoke Alarm 0
14 Aico Carbon Monoxide Alarm Ei 220EN User manual Smoke Alarm 0
15 Aico Ei164RC User manual Smoke Alarm 5