National Instruments 8-Channel, 24 V Logic, Sinking Digital Input Device user manual

User manual for the device National Instruments 8-Channel, 24 V Logic, Sinking Digital Input Device

Device: National Instruments 8-Channel, 24 V Logic, Sinking Digital Input Device
Category: Computer Hardware
Manufacturer: National Instruments
Size: 0.61 MB
Added : 4/28/2014
Number of pages: 18
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for National Instruments 8-Channel, 24 V Logic, Sinking Digital Input Device. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with National Instruments 8-Channel, 24 V Logic, Sinking Digital Input Device.

For your convenience

If looking through the National Instruments 8-Channel, 24 V Logic, Sinking Digital Input Device user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual National Instruments 8-Channel, 24 V Logic, Sinking Digital Input Device on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual National Instruments 8-Channel, 24 V Logic, Sinking Digital Input Device to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
National Instruments 8-Channel, 24 V Logic, Sinking Digital Input Device User manual - Online PDF
Advertisement
« Page 1 of 18 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual National Instruments 8-Channel, 24 V Logic, Sinking Digital Input Device but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to National Instruments 8-Channel, 24 V Logic, Sinking Digital Input Device. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

Hi-Speed USB Carrier
NI USB-9162
Hi-SPeed USB Carrier
NI USB-9162
USER GUIDE AND SPECIFICATIONS
NI USB-9421
8-Channel, 24 V Logic, Sinking Digital Input Device
This user guide describes how to use the National Instruments USB-9421
and lists the device specifications. In this user guide, the NI USB-9421 with
screw terminal and the NI USB-9421 with D-SUB are referred to
inclusively as the NI USB-9421.
Introduction
The NI USB-9421 data acquisition device provides a USB interface with
connection

Summary of the content on the page No. 2

Dimensions Figures 2 and 3 show the NI USB-9421 device dimensions. Hi-Speed USB Carrier NI USB-9162 140.23 mm 120.68 mm (5.521 in.) (4.751 in.) 137.82 mm 118.26 mm (5.426 in.) (4.656 in.) 88.12 mm 25.34 mm (3.469 in.) (0.998 in.) Figure 2. NI USB-9421 (Screw Terminal) Device in Millimeters (Inches) Hi-Speed USB Carrier NI USB-9162 125.76 mm 120.68 mm (4.951 in.) (4.751 in.) 123.38 mm 118.26 mm (4.857 in.) (4.656 in.) 88.12 mm 25.34 mm (3.469 in.) (0.998 in.) Figure 3. NI USB-9421 (D-SUB)

Summary of the content on the page No. 3

Safety Guidelines Operate the NI USB-9421 only as described in these operating instructions. Note Although the NI 9421 module may have more stringent certification standards than the NI USB-9421, when used with the NI USB-9162 carrier, the combined system may be limited. Refer to the Specifications section for more details. Hot Surface This icon denotes that the component may be hot. Touching this component may result in bodily injury. Caution Do not disconnect I/O-side wires or connectors un

Summary of the content on the page No. 4

Related Documentation Each application software package and driver includes information about writing applications for taking measurements and controlling measurement devices. The following references to documents assume you have NI-DAQmx 8.7 or later, and where applicable, version 7.1 or later of the NI application software. NI-DAQmx for Windows The DAQ Getting Started Guide describes how to install your NI-DAQmx for Windows software, your NI-DAQmx-supported DAQ device, and how to confirm

Summary of the content on the page No. 5

� Taking Measurements—Contains the conceptual and how-to information you need to acquire and analyze measurement data in LabVIEW, including common measurements, measurement fundamentals, NI-DAQmx key concepts, and device considerations. LabWindows/CVI The Data Acquisition book of the LabWindows/CVI Help contains measurement concepts for NI-DAQmx. This book also contains Taking an NI-DAQmx Measurement in LabWindows/CVI, which includes step-by-step instructions about creating a measurement t

Summary of the content on the page No. 6

ANSI C without NI Application Software The NI-DAQmx Help contains API overviews and general information about measurement concepts. Select Start»All Programs»National Instruments»NI-DAQ»NI-DAQmx Help. The NI-DAQmx C Reference Help describes the NI-DAQmx Library functions, which you can use with National Instruments data acquisition devices to develop instrumentation, acquisition, and control applications. Select Start»All Programs»National Instruments»NI-DAQ» NI-DAQmx C Reference Help. .NET

Summary of the content on the page No. 7

Training Courses If you need more help getting started developing an application with NI products, NI offers training courses. To enroll in a course or obtain a detailed course outline, refer to ni.com/training. Technical Support on the Web For additional support, refer to ni.com/support or zone.ni.com. Installing the Software Software support for the NI USB-9421 for Windows Vista/XP/2000 is provided by NI-DAQmx. The DAQ Getting Started Guide, which you can download at ni.com/manuals, offe

Summary of the content on the page No. 8

3. Align the I/O module with the carrier, as shown in Figure 4. 1 1 High Voltage Screw Terminal Backshell Figure 4. Module Installation 4. Squeeze the latches and insert the NI 9421 module into the NI USB-9162 carrier. 5. Press firmly on the connector side of the NI 9421 module until the latches lock the module into place, as shown in Figure 5. Figure 5. Locking Module into Place NI USB-9421 User Guide and Specifications 8 ni.com

Summary of the content on the page No. 9

Mounting the NI USB-9421 to a Panel Threaded inserts are located in the NI USB-9421 for mounting it to a panel. Refer to Figure 6 for dimensions. 85.7 mm (3.37 in.) 72.2 mm (2.84 in.) Threaded Insert M3 x 0.5 8.5 mm (0.34 in.) Max Depth 76.1 mm (3.00 in.) Figure 6. Module Dimensions in Millimeters (Inches) Connecting the NI USB-9421 to a Computer Plug one end of the USB cable into the NI USB-9421 and the other end into an available USB port on the computer. Refer to the NI-DAQmx for USB Devi

Summary of the content on the page No. 10

Table 1. LED State/Device Status LED State Device Status Not lit Device not connected or in suspend. On, not blinking Device connected, but no module installed. Single-blink Operating normally. Double-blink Operating normally. Quadruple-blink Device error. Refer to ni.com/support. Wiring the NI USB-9421 Device Caution A high voltage screw terminal backshell must be installed when using hazardous voltages (>42.4 V , 60 VDC). pk Note Table 2 illustrates the accessories available from ni.com for

Summary of the content on the page No. 11

Each channel of the NI USB-9421 has a terminal or pin, DI, to which you can connect voltage or current signals. The NI USB-9421 also has a common terminal or pin, COM, that is internally connected to the isolated reference of the module. Each digital input channel on the NI USB-9421 has an LED that indicates the state of that channel. Refer to Table 3 for the terminal assignments of the NI USB-9421 with screw terminal. Refer to Figure 7 for the pin assignments of the NI USB-9421 with D-SUB

Summary of the content on the page No. 12

0 3 47 1 COM DI0 14 2 NC NC 15 3 COM DI1 16 4 COM DI2 17 5 NC NC 18 6 COM DI3 19 7 COM DI4 20 8 NC NC 21 9 COM DI5 22 10 COM DI6 23 11 NC NC 24 12 COM DI7 25 13 COM Figure 7. Pin Assignments Connecting Devices to the NI USB-9421 The NI USB-9421 has sinking inputs, meaning that when current goes through or voltage is applied to the DI terminal or pin, DI provides a path to ground for the current or voltage. The NI USB-9421 internally limits current signals connected to DI. For more informatio

Summary of the content on the page No. 13

Sourcing-Output Device DI External + Power _ NI USB-9421 Supply COM Figure 8. Connecting a Device to the NI USB-9421 (3-Wire Device Shown) The NI USB-9421 channel registers as ON when the sourcing-output device applies a voltage or drives a current to DI that is in the input ON range. The channel registers as OFF when the device applies a voltage or drives a current to DI that is in the input OFF range. If no device is connected to DI, the channel registers as OFF. The channel LED turns on

Summary of the content on the page No. 14

Figure 10. Assembled High Voltage Screw Terminal Backshell Specifications The following specifications are typical for the range 0 to 60 °C unless otherwise noted. All voltages are relative to COM unless otherwise noted. Input Characteristics Number of channels................................8 Input type................................................Sinking Digital logic levels OFF state Input voltage.............................≤5V Input current .............................≤300 μA ON state

Summary of the content on the page No. 15

Bus Interface USB specification .................................. USB 2.0 Hi-Speed Physical Characteristics Dimensions With screw terminal........................ 14.0 cm × 8.8 cm × 2.5 cm (5.52 in. × 3.47 in. × 1.00 in.) With 25-pin D-SUB ........................ 12.6 cm × 8.8 cm × 2.5 cm (4.95 in. × 3.47 in. × 1.00 in.) Screw-terminal wiring............................ 12 to 24 AWG copper conductor wire with 10 mm (0.39 in.) of insulation stripped from the end Torque for screw terminals ...

Summary of the content on the page No. 16

NI USB-9421 with D-SUB Safety Voltages Channel-to-COM ....................................30 V max Isolation Channel-to-channel..........................No isolation between channels Channel-to-earth ground Withstand .................................1,000 V , verified by a 5 second rms dielectric withstand test Continuous ...............................60 VDC, Measurement Category I Measurement Category I is for measurements performed on circuits not directly connected to the electrical distr

Summary of the content on the page No. 17

Operating humidity (IEC 60068-2-56)................................... 10 to 90% RH, noncondensing Storage humidity (IEC 60068-2-56)................................... 5 to 95% RH, noncondensing Maximum altitude .................................. 2,000 m Pollution Degree (IEC 60664) ............... 2 Electromagnetic Compatibility This product is designed to meet the requirements of the following standards of EMC for electrical equipment for measurement, control, and laboratory use: � EN 61326

Summary of the content on the page No. 18

Waste Electrical and Electronic Equipment (WEEE) EU Customers At the end of their life cycle, all products must be sent to a WEEE recycling center. For more information about WEEE recycling centers and National Instruments WEEE initiatives, visit ni.com/environment/weee.htm. RoHS National Instruments (RoHS) ni.com/environment/rohs_china National Instruments RoHS (For information about China RoHS compliance, go to ni.com/environment/rohs_china.) Where to Go


Alternative user manuals
# User manual Category Download
1 National Instruments 8252 User manual Computer Hardware 3
2 National Instruments 1143 User manual Computer Hardware 1
3 National Instruments PXI-846x User manual Computer Hardware 0
4 National Instruments 3.21E+04 User manual Computer Hardware 1
5 National Instruments HPC467064 User manual Computer Hardware 0
6 National Instruments 4-Channel, +_ VDC, 16-Bit Simultaneous Sampling Analog Input Devices User manual Computer Hardware 0
7 National Instruments 1142 User manual Computer Hardware 0
8 National Instruments NI PCIe-836x User manual Computer Hardware 1
9 National Instruments CAN Hardware User manual Computer Hardware 0
10 National Instruments 1141 User manual Computer Hardware 0
11 National Instruments 321372C-01 User manual Computer Hardware 2
12 National Instruments MXI-Express Multisystem eXtension Interface for PCI Express, Compact PCI, and PXI Bus Computers User manual Computer Hardware 0
13 National Instruments PXI-846x Series User manual Computer Hardware 0
14 National Instruments network module User manual Computer Hardware 0
15 National Instruments NI PXI/PCI-5114 User manual Computer Hardware 0
16 Sony MSAKIT-PC4A User manual Computer Hardware 2
17 Sony MRW62E-S1 2694866142 User manual Computer Hardware 5
18 Philips MATCH LINE 9596 User manual Computer Hardware 17
19 Sony 64GB SDHC Class 10 Memory Card Readers SF32UY User manual Computer Hardware 1
20 Philips PSC702 User manual Computer Hardware 1