National Instruments NI PXI/PCI-5114 user manual

User manual for the device National Instruments NI PXI/PCI-5114

Device: National Instruments NI PXI/PCI-5114
Category: Computer Hardware
Manufacturer: National Instruments
Size: 0.22 MB
Added : 4/28/2014
Number of pages: 20
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for National Instruments NI PXI/PCI-5114. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with National Instruments NI PXI/PCI-5114.

For your convenience

If looking through the National Instruments NI PXI/PCI-5114 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual National Instruments NI PXI/PCI-5114 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual National Instruments NI PXI/PCI-5114 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
National Instruments NI PXI/PCI-5114 User manual - Online PDF
Advertisement
« Page 1 of 20 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual National Instruments NI PXI/PCI-5114 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to National Instruments NI PXI/PCI-5114. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

NI PXI/PCI-5114 Specifications
8-Bit 250 MS/s Digitizer
Unless otherwise noted, the following conditions were used for each
specification:
• All filter settings
� All impedance selections
� Sample clock set to 250 MS/s
Typical values are representative of an average unit operating at room
temperature. Specifications are subject to change without notice. For the
most recent NI 5114 specifications, visit ni.com/manuals.
To access the NI 5114 documentation, including the NI High-Speed
Digitizer

Summary of the content on the page No. 2

Power .......................................................................................................14 Software...................................................................................................15 Environment ............................................................................................16 NI PXI-5114 .....................................................................................16 NI PCI-5114 ...........................................................

Summary of the content on the page No. 3

Specification Value Comments Voltage Levels Full Scale (FS) 50 Ω 1 MΩ — Input Range and Range Vertical Offset Range Vertical Offset Programmable (V ) Range (V) (V ) Range (V) pk-pk pk-pk Vertical Offset 0.04 ±0.8 0.04 ±0.8 0.1 ±0.8 0.1 ±0.8 0.2 ±0.8 0.2 ±0.8 0.4 ±0.8 0.4 ±0.8 1 ±6.5 1.0 ±8.0 2 ±6.0 2.0 ±8.0 4 ±5.0 4.0 ±8.0 10 ±30 10 ±2.0 20 ±25 40 ±15 Maximum Input 50 Ω 1 MΩ — Overload 7 V with |Peaks| ≤ 10 V |Peaks| ≤ 35 V rms Accuracy Resolution 8 bits — DC Accuracy NI PXI-5114: Within ±5 °

Summary of the content on the page No. 4

Specification Value Comments Bandwidth and Transient Response Bandwidth Range Rise/Fall Time, — (–3 dB) (V ) Bandwidth Typical pk-pk All ranges 125 MHz 2.8 ns except 0.04 0.04 100 MHz 3.5 ns Bandwidth — 20 MHz Noise Filter Limit Filter AC Coupling* *AC coupling Cutoff (–3 dB), 12 Hz available on Typical 1 MΩ only. Passband Referenced to Flatness 50 kHz. ±1 dB up to 50 MHz Bandwidth limit filter off. 1 0 –1 –2 –3 –4 Full Bandwidth –5 –6 Noise Filter –7 –8 –9 –10 1 M 10 M 100 M 200 M Frequenc

Summary of the content on the page No. 5

Specification Value Comments Spectral Characteristics Range (V ) 10 MHz, pk-pk –1 dBFS Spurious Free All ranges except 0.04 0.04 input signal. Dynamic Range with Harmonics Includes the –58 dBc –58 dBc nd (SFDR), Typical 2 through th the 5 Total Harmonic harmonics. Distortion –58 dBc –58 dBc Measured (THD), Typical from DC to Effective 125 MHz. Number of Bits 7.2 6.2 20 MHz (ENOB), bandwidth Calculated* limit filter off. Signal to Noise and Distortion 44 dB 38 dB (SINAD), Typica

Summary of the content on the page No. 6

Horizontal Sample Clock Specification Value Comments Sources Internal, Onboard Clock (internal VCXO)* * Internal Sample Clock is locked to the External, CLK IN (front panel SMB connector) Reference Clock or derived from the onboard VCXO. Onboard Clock (Internal VCXO) Sample Rate Real-Time Sampling Random Interleaved * Divide by n Range (Single Shot) Sampling (RIS) decimation used for all rates less than 3.815 kS/s to 250MS/s* 250 MS/s to 5 GS/s in 250 MS/s. For more increments of 25

Summary of the content on the page No. 7

Specification Value Comments External Sample Clock Sources CLK IN (front panel SMB connector) — Frequency 50 MHz to 250 MHz Divide by n Range decimation available where 1 ≤ n ≤ 65,535. For more information about Sample Clock and decimation, refer to the NI High-Speed Digitizers Help. Duty Cycle 45% to 55% — Tolerance Phase-Locked Loop (PLL) Reference Clock Specification Value Comments Sources NI PXI-5114 NI PCI-5114 — PXI_CLK10 (backplane RTSI 7 connector) CLK IN (front panel SMB CLK I

Summary of the content on the page No. 8

CLK IN (Sample Clock and Reference Clock Input, Front Panel Connector) Specification Value Comments Input Voltage Sine wave: 0.65 V to 2.8 V (0 dBm to 13 dBm) — pk-pk pk-pk Range Square wave: 0.2 V to 2.8 V pk-pk pk-pk Maximum Input 7 V with |Peaks| ≤ 10 V — rms Overload Impedance 50 Ω — Coupling AC — Trigger Reference (Stop) Trigger Specification Value Comments Trigger Types Types Sources Refer to the and Sources following Edge, Window, Hysteresis, CH 0, CH 1, TRIG, sections and to Video,

Summary of the content on the page No. 9

Specification Value Comments Analog Trigger (Edge, Window, and Hysteresis Trigger Types) Sources CH 0 (front panel BNC connector) — CH 1 (front panel BNC connector) TRIG (front panel BNC connector) Trigger Level 8 bits (1 in 256) Resolution CH 0, CH 1 TRIG (External Trigger) — Trigger Level 100% FS ±5 V Range Edge Trigger 5% FS up to 100 MHz 0.5 V up to 100 MHz pk-pk Sensitivity Level ±5% FS up to 10 MHz ±0.5 V up to 10 MHz Accuracy, Typical Jitter ≤ 65 ps rms — Trigger Filters Low Frequency (

Summary of the content on the page No. 10

Specification Value Comments Types Specific Line — Any Line Specific Field Standards SDTV: M-NTSC, B/G-PAL, SECAM, M-PAL fps = fields per second; EDTV: 480i/59.94 fps, 480i/60 fps, 480p/59.94 Fps, 480p/60 Fps, 576i/50 fps, 576p/50 Fps Fps = Frames per second HDTV: 720p/50 Fps, 720p/59.94 Fps, 720p/60 Fps, 1080i/50 fps, 1080i/59.94 fps, 1080i/60 fps, 1080p/24 Fps TRIG (External Trigger, Front Panel Connector) Specification Value Comments Connector BNC — Impedance 1 MΩ in parallel with 22 pF

Summary of the content on the page No. 11

Specification Value Comments As an Input (Trigger) Destinations Start Trigger (Acquisition Arm) — Reference (Stop) Trigger Arm Reference Advance Trigger Input Impedance 150 kΩ — V 2.0 V — IH V 0.8 V — IL Maximum Input –0.5 V to 5.5 V — Overload Maximum 25 MHz — Frequency As an Output (Event) Sources Start Trigger (Acquisition Arm) — Reference (Stop) Trigger End of Record Done (End of Acquisition) Probe Compensation (1 kHz, 50% duty cycle square wave, PFI 1 only) Output Impedance 50 Ω — Logic Ty

Summary of the content on the page No. 12

TClk Specifications National Instruments TClk synchronization method and the NI-TClk driver are used to align the sample clocks on any number of SMC-based modules in a chassis. For more information about TClk synchronization, refer to the NI-TClk Synchronization Help, which is located within the NI High-Speed Digitizers Help. � Specifications are valid for any number of modules installed in one NI PXI-1042 chassis. � All parameters set to identical values for each SMC-based module. � Sample

Summary of the content on the page No. 13

Waveform Specifications Specification Value Comments Onboard Memory 8 MB per Channel 8 megasamples — Size Standard per channel 64 MB per Channel 64 megasamples Option per channel 256 MB per Channel 256 megasamples Option per channel Minimum Record 1 Sample — Length Number of Zero up to full Record Length Single-record Pretrigger Samples mode and multiple-record mode. Number of Zero up to full Record Length Single-record Posttrigger Samples mode and multiple-record mode. Maximum Numb

Summary of the content on the page No. 14

Calibration Specification Value Comments Self-Calibration Self-calibration is done on software command. — The calibration corrects for gain, offset, compensated 1 MΩ attenuator, triggering, and timing adjustment errors for all input ranges. External Calibration The external calibration calibrates the VCXO, gain, — (Factory Calibration) and the voltage reference. Appropriate constants are stored in nonvolatile memory. Interval for External 2 years — Calibration Warm-Up Time 15 minutes — Power

Summary of the content on the page No. 15

Software Specification Value Comments Driver Software NI PXI-5114: NI-SCOPE 2.9 or later. — NI PCI-5114: NI-SCOPE 3.1 or later. NI-SCOPE is an IVI-compliant driver that allows you to configure, control, and calibrate the NI 5114. NI-SCOPE provides application programming interfaces for many development environments. Application NI-SCOPE provides programming interfaces, — Software documentation, and examples for the following application development environments: �LabVIEW ™ ™ � LabWindows /CV

Summary of the content on the page No. 16

Environment NI PXI-5114 Note To ensure that the NI PXI-5114 cools effectively, follow the guidelines in the Maintain Forced Air Cooling Note to Users included in the NI PXI-5114 kit. The NI PXI-5114 is intended for indoor use only. Specification Value Comments Operating 0 ºC to +55 ºC in all NI PXI chassis except the following: — Temperature 0 ºC to +45 ºC when installed in an NI PXI-1000/B or PXI-101x chassis. Meets IEC-60068-2-1 and IEC-60068-2-2. Storage – 40 ºC to +71 ºC. Meets IEC-60068

Summary of the content on the page No. 17

NI PCI-5114 Note To ensure that the NI PCI-5114 cools effectively, follow the guidelines in the Maintain Forced Air Cooling Note to Users included in the NI PCI-5114 kit. Also, to maximize airflow and extend the life of the device, leave any adjacent PCI slots empty. The NI PCI-5114 is intended for indoor use only. Specification Value Comments Operating 0 ºC to +45 ºC. Meets IEC-60068-2-1 and IEC-60068-2-2. — Temperature Storage – 40 ºC to +71 ºC. Meets IEC-60068-2-1 and — Temperature IEC-600

Summary of the content on the page No. 18

Safety, Electromagnetic Compatibility, and CE Compliance Specification Value Comments Safety The NI 5114 meets the requirements of the following — standards of safety for electrical equipment for measurement, control, and laboratory use: � IEC 61010-1, EN 61010-1 � UL 61010-1, CAN/CSA-C22.2 No. 61010-1 For UL and other safety certifications, refer to the product label or visit ni.com/certification, search by model number or product line, and click the appropriate link in the Certification col

Summary of the content on the page No. 19

Physical Specification Value Comments Dimensions NI PXI-5114 NI PCI-5114 — 3U, One slot, 35.5 × 2.0 × 11.3 cm PXI/cPCI Module (13.4 × 0.8 × 4.4 in.) 21.6 × 2.0 × 13.0 cm (8.5 × 0.8 × 5.1 in.) Weight 455 g (16 oz) 421 g (14.8 oz) — Front Panel Connectors Label Function Connector Type — CH 0 Analog Input BNC female CH 1 Analog Input BNC female TRIG External Trigger BNC female CLK IN Sample Clock Input and SMB jack Reference Clock Input AUX I/O PFI 0, PFI 1 9-pin mini-circular DIN NI PXI-5114 F

Summary of the content on the page No. 20

Where to Go for Support The National Instruments Web site is your complete resource for technical support. At ni.com/support you have access to everything from troubleshooting and application development self-help resources to email and phone assistance from NI Application Engineers. A Declaration of Conformity (DoC) is our claim of compliance with the Council of the European Communities using the manufacturer’s declaration of conformity. This system affords the user protection for electro


Alternative user manuals
# User manual Category Download
1 National Instruments 8-Channel, 24 V Logic, Sinking Digital Input Device User manual Computer Hardware 0
2 National Instruments 8252 User manual Computer Hardware 3
3 National Instruments 1143 User manual Computer Hardware 1
4 National Instruments PXI-846x User manual Computer Hardware 0
5 National Instruments 3.21E+04 User manual Computer Hardware 1
6 National Instruments HPC467064 User manual Computer Hardware 0
7 National Instruments 4-Channel, +_ VDC, 16-Bit Simultaneous Sampling Analog Input Devices User manual Computer Hardware 0
8 National Instruments 1142 User manual Computer Hardware 0
9 National Instruments NI PCIe-836x User manual Computer Hardware 1
10 National Instruments CAN Hardware User manual Computer Hardware 0
11 National Instruments 1141 User manual Computer Hardware 0
12 National Instruments 321372C-01 User manual Computer Hardware 2
13 National Instruments MXI-Express Multisystem eXtension Interface for PCI Express, Compact PCI, and PXI Bus Computers User manual Computer Hardware 0
14 National Instruments PXI-846x Series User manual Computer Hardware 0
15 National Instruments network module User manual Computer Hardware 0
16 Sony MSAKIT-PC4A User manual Computer Hardware 2
17 Sony MRW62E-S1 2694866142 User manual Computer Hardware 5
18 Philips MATCH LINE 9596 User manual Computer Hardware 17
19 Sony 64GB SDHC Class 10 Memory Card Readers SF32UY User manual Computer Hardware 1
20 Philips PSC702 User manual Computer Hardware 1