Streszczenie treści zawartej na stronie nr. 1 
                    
                        Agilent N9340A 
Handheld 
Spectrum Analyzer
User’s Guide
                                                                                                                                                                                                                                                                                                                                                                                                                                                           
                    
                    Streszczenie treści zawartej na stronie nr. 2 
                    
                        Notices © Agilent Technologies, Inc. 2007 Warranty No part of this manual may be reproduced  The material contained in this document  in any form or by any means (including  is provided “as is,” and is subject to  electronic storage and retrieval or  being changed, without notice, in future  translation into a foreign language)  editions. Further, to the maximum extent  without prior agreement and written  permitted by applicable law, Agilent  consent from Agilent Technologies, Inc. as  disclaim
                    
                    Streszczenie treści zawartej na stronie nr. 3 
                    
                        Notices © Agilent Technologies, Inc. 2007 Warranty No part of this manual may be reproduced  The material contained in this document  in any form or by any means (including  is provided “as is,” and is subject to  electronic storage and retrieval or  being changed, without notice, in future  translation into a foreign language)  editions. Further, to the maximum extent  without prior agreement and written  permitted by applicable law, Agilent  consent from Agilent Technologies, Inc. as  disclaim
                    
                    Streszczenie treści zawartej na stronie nr. 4 
                    
                        A CAUTION notice denotes a hazard. It calls attention to  CAU CAU TIO -N an operating procedure, practice, or the like that, if not  correctly performed or adhered to, could result in damage  to the product or loss of important data. Do not proceed  beyond a CAUTION notice until the indicated conditions  are fully understood and met.  A WARNING notice denotes a hazard. It calls attention to  WARNING an operating procedure, practice, or the like that, if not  correctly performed or adhered to, co
                    
                    Streszczenie treści zawartej na stronie nr. 5 
                    
                        Table of Contents 1 N9340A Overview Introduction    2 Functionality    2 Optimized Usability    3 Front Panel Overview    4 Top Panel Overview    5 Display Annotations    6 Working with Batteries    7 Installing a Battery    7 Viewing Battery Status    7 Charging a Battery    8 2 Getting Started Checking Shipment and Order List    10 Power Requirements    11 AC Power Cords    12 Safety Considerations    13 Electrical Requirements    15 Electrostatic Discharge (ESD) Precautions    15 Instrument M
                    
                    Streszczenie treści zawartej na stronie nr. 6 
                    
                        Measuring a Low-Level Signal    31 Improving Frequency Resolution and Accuracy    36 Making Distortion Measurements    37 One-button Power Measurement    43 Making a Stimulus Response Transmission Measurement    47 Measuring Stop Band Attenuation of a Low-pass Filter    49 Making a Reflection Calibration Measurement    51 Measuring Return Loss Using the Reflection Calibration Routine    54 4 System Setting Visual and Audio Adjustment    56 Quick Display Adjustment    56 Manual Display Adjustment
                    
                    Streszczenie treści zawartej na stronie nr. 7 
                    
                        Y Axis Units    72 BW/SWP    73 RBW    73 VBW    74 VBW/RBW    74 Avg Type    74 Sweep Time    76 Sweep    77 Enter    79 ESC/CLR    80 Frequency    81 Center Frequency    81 Start Frequency    81 Stop Frequency    81 CF Step    82 Marker    83 Marker    83 Normal    83 Delta    84 Off    84 Mode    86 Marker Trace    87 All Off    87 Meas    88 Span    89 Span    89 Full    89 Zero    89 Last Span    89 TRACE    90 Trace    90 Clear Write    90 Max Hold    90 Minimum Hold    91 View    91 Blank
                    
                    Streszczenie treści zawartej na stronie nr. 8 
                    
                        Save Trace    94 Save As    94 Recall Trace    94 Limit    95 Limit Line    95 Limit Pattern    95 Set Pattern    95 Limit Type    95 Beep    96 Save Pattern    96 Recall Pattern    96 6 SCPI Command Reference SCPI Language Basics    98 Basic Knowledge Requirement    99 Command Categories    99 Command Syntax    99 Standard Notations    100 Default unit of parameters    101 Common Commands    102 Clear Status    102 Identification Query    102 Reset    102 CALCulate Subsystem    103 Limit Line S
                    
                    Streszczenie treści zawartej na stronie nr. 9 
                    
                        Initiate a single sweep    117 INSTrument Subsystem    118 Select One button measurement    118 MEASure Subsystem    119 OBW Subsection    119 ACPR Subsection    119 SENSe Subsystem    123 [:SENSe]:AVERage Subsection    123 FREQuency Subsection    128 SWEep Subsection    132 SYSTem Subsystem    133 Ext Input    133 Date Query    133 Time Query    133 Error Information Query    133 TRACe Subsystem    134 Tracking Generator Subsystem    135 State    135 Output Amplitude    135 Amplitude Offset    
                    
                    Streszczenie treści zawartej na stronie nr. 10 
                    
                        Trigger Source    139 UNIT Subsystem    141 7Error Messages Error Message List    144 8 Menu Map AMPTD    150 BW/SWP    151 FREQ    152 MARKER    153 MEAS    154 SPAN    155 SYS    156 TRACE    157 Limit    158 6                                                                                                                                                                                                                                                                                                
                    
                    Streszczenie treści zawartej na stronie nr. 11 
                    
                        Agilent N9340A  Handheld Spectrum Analyzer 1 N9340A Overview Agilent Technologies 1                                                                                                                                                                                                                                                                                                                                                                                                                                 
                    
                    Streszczenie treści zawartej na stronie nr. 12 
                    
                        1 N9340A Overview Introduction An Agilent N9340A is a handheld spectrum  analyzer with a frequency range from 100 kHz to 3  GHz, tunable to 9 kHz. The analyzer provides  ultimate measurement flexibility in a package that  is ruggedized for field environments and  convenient for mobile applications. Functionality An Agilent N9340A provides your with  comprehensive functionality set and measurement  convenience, including: 1 Pass/Fail judgement  Sets limit lines on the display for a quick  Pass/Fa
                    
                    Streszczenie treści zawartej na stronie nr. 13 
                    
                        N9340A Overview 1 4 Power Suite  Provides one-button measurement functionality  on OBW (Occupied Bandwidth), channel power, and  ACPR (Adjacent Channel Power Ratio). 5 High-sensitivity measurement  Includes a 3 GHz pre-amplifier (Option  N9340A-PA3) enabling highly sensitive  measurement which helps in the analysis of   low-level signals. Optimized Usability An Agilent N9340A handheld spectrum analyzer  provides enhanced usability: • 7.2-inch sunlight viewable screen ( 640 × 480  pixels) enables
                    
                    Streszczenie treści zawartej na stronie nr. 14 
                    
                        1 N9340A Overview Front Panel Overview 12 14 13 N9340A  100 kHz - 3.0 GH z HANDHELD SPECTR UM ANAL YZER       11 10 1 AB C 2DEF 3 GHI 4JKL 5MNO 6 PQ R 9 STU VWX YZ_ 7 8 9 0SAVE LIMIT MARKE R ES C /C L R  P R ES ET 8 ENT ER BW / SYS MO D E ME A S T R A C E AMP TD SPAN FREQ SW P 7 6 1 2 3 4 5 Caption Function 1 Power Switch Toggles the analyzer between on and off  2 SYS Brings up a submenu for system setup 3 Function keys Includes hardkeys: FREQ, SPAN, AMPTD, BW/SWP, TRACE,  MEAS, and MODE 4 Prese
                    
                    Streszczenie treści zawartej na stronie nr. 15 
                    
                        N9340A Overview 1 Top Panel Overview 8 7 9     50 VDC MAX    33 dBm (2 W) MAX EXT TRIG IN/ RF INPUT 50 EXT REF IN RF OUT 50  Ext. Power  Charging PC 12-18 VDC 12-18 VDC  55 80   W M W MA A X X 1 2 3 4 5 6 1. DC Connector Provides input for the DC power source via an  AC-DC adapter. (Make sure that the line-power  source outlet has a protective ground contact.) 2. Charging indicator Lights when the battery is charging. 3. External power indicator Lights when an external DC power applied to  the a
                    
                    Streszczenie treści zawartej na stronie nr. 16 
                    
                        1 N9340A Overview Display Annotations 14 1 13 12 2   3 4 11 5 6 8 9 10 7 Description Associated Function Key 1Time and Date [SYS] > {Setting} > {General}  2 Reference Level [AMPTD]  3 Amplitude Scale [AMPTD]  4 Detector Mode [TRACE] > {More (1 of 2)} > {Detector} 5 Center Frequency [FREQ] > {Center Freq} 6 Resolution Bandwidth [BW/SWP] > {RBW} 7 Display Status Line Displays analyzer status and error messages. 8Video Bandwidth [BW/SWP] > {VBW} 9Frequency Span [SPAN] 10 Sweep Time [BW/SWP] > {Swee
                    
                    Streszczenie treści zawartej na stronie nr. 17 
                    
                        N9340A Overview 1 Working with Batteries Use the original battery supplied with the  instrument or a genuine equivalent replacement  from Agilent.  Installing a Battery Insert a battery, ensuring correct orientation with the  CAU CAU TIO -N electrodes correctly aligned. Step Notes 1 Open the battery cover Use a cross-head type screwdriver to  remove the screw, then pull the cover  open. 2 Insert the battery 3 Close the battery cover Push the cover closed, then refasten  the screw. Viewing Batter
                    
                    Streszczenie treści zawartej na stronie nr. 18 
                    
                        1 N9340A Overview Charging a Battery You can only charge the battery when it is in the  analyzer either in operating or when the analyzer  is shut down. Fully charge the battery before  first using the analyzer. This typically takes  about four hours.  Never use a modified or damaged AC-DC adapter. CAU CAU TIO -N 1 Install the battery in the analyzer. 2 Simply attach the AC-DC adapter and switch on  external power. 3 The charge indicator lights, indicating that the  battery is charging. When the
                    
                    Streszczenie treści zawartej na stronie nr. 19 
                    
                        Agilent N9340A                                                                            Handheld  Spectrum Analyzer 2 Getting Started Conventions 1. A pair of curly brackets { } indicates a softkey, for example  {Start} refers to the Start softkey. 2. A pair of square brackets [ ] indicates a hardkey,   for example, [ENTER] refers to the ENTER hardkey. 3. An analyzer refers to Agilent N9340A handheld spectrum  analyzer in the following chapters. 4. A DUT refers to a device under test. Agilent 
                    
                    Streszczenie treści zawartej na stronie nr. 20 
                    
                        2 Getting Started Checking Shipment and Order List We recommend you check the shipment and order  list according to the following procedure when you  receive the shipment.   Inspect the shipping container for damages.  Signs of damage may include a dented or torn  shipping container or cushioning material that  indicate signs of unusual stress or compacting.  Carefully remove the contents from the shipping  container, and check your shipment.  For any question or problem, contact Agilent  Tec