Streszczenie treści zawartej na stronie nr. 1 
                    
                        www.excalibur-fi re.com
Owners & 
P90 Zero Clearance Direct Vent Gas Fireplace
Installation Manual
MODELS:    P90-NG1 Natural Gas     P90-LP1 Propane
WARNING:  
FOR YOUR SAFETY
If the information in these instructions are not followed exactly, 
What to do if you smell gas:
a fi re or explosion may result causing property damage, 
 Do not try to light any appliance
personal injury or loss of life.  
 Do not touch any electrical switch: 
do not use any phone in your 
FOR YOUR SAFETY
building.
Do n
                    
                    Streszczenie treści zawartej na stronie nr. 2 
                    
                        To the New Owner: Congratulations!  ® You are the owner of a state-of-the-art Excalibur Gas Fireplace by  FPI FIREPLACE PRODUCTS  INTERNATIONAL LTD.  The P90 is a hand crafted appliance and has been designed to provide  you with all  the warmth and charm of a wood fi replace at the fl ick of a switch.  The model P90 has  been approved by Warnock Hersey for both safety and effi ciency.  As it also bears our own mark,  it promises to provide you with economy, comfort and security for many trouble fre
                    
                    Streszczenie treści zawartej na stronie nr. 3 
                    
                        TABLE OF CONTENTS Glass Door Installation ................................................31 SAFETY LABEL  Arch Surround .............................................................31 Optional Screen Door  .................................................31 Serial No. Decal   ..........................................................4 Accent Kit Installation ..................................................32 Option 1: Remote Control ............................................33 REQUIREMENTS 
                    
                    Streszczenie treści zawartej na stronie nr. 4 
                    
                        SAFETY LABEL This is a copy of the label that accompanies each  P90 Zero Clearance Direct Vent Gas Fireplace.  We have printed a copy of the contents here for  your review. The safety label is located on the  front inside base of the unit, visible when the  bottom louver is open. ® NOTE: Excalibur units are constantly being  improved. Check the label on the unit and if  there is a difference, the label on the unit is the  correct one. Wall For the State of Massachusetts, installation  and repair
                    
                    Streszczenie treści zawartej na stronie nr. 5 
                    
                        REQUIREMENTS  MA Code - CO Detector (for the State of Massachusetts only) 5.08: Modifications to NFPA-54, Chapter 10 (2) Revise 10.8.3 by adding the following additional requirements:  (a) For all side wall horizontally vented gas fueled equipment installed in every dwelling, building or structure used in whole or in part for  residential purposes, including those owned or operated by the Commonwealth and where the side wall exhaust vent termination is less than  seven (7) feet above finished gr
                    
                    Streszczenie treści zawartej na stronie nr. 6 
                    
                        INSTALLATION Emissions from burning  wood or gas could  IMPORTANT MESSAGE   GENERAL SAFETY  contain chemicals known to the State of  SAVE THESE INFORMATION California to  cause cancer, birth defects or  other reproductive harm. INSTRUCTIONS 1) The appliance installation must conform  with local codes or, in the absence of local  The P90-NG1 or P90-LP1 Direct Vent Fireplace  codes, with the current Canadian or National  INSTALLATION  must be installed in accordance with these Gas Codes, CAN1-B149
                    
                    Streszczenie treści zawartej na stronie nr. 7 
                    
                        INSTALLATION Clearance to Combustibles from: LOCATING YOUR  MANUFACTURED    Back 0" (0mm)    Side 0" (0mm) GAS FIREPLACE MOBILE HOME    Floor 0" (0mm)   ADDITIONAL  1) When selecting a location for your fi replace,  ensure that the clearances outlined on this  REQUIREMENTS NOTE: The minimum fl oor clearance must  page are met. be maintained from the top surface of the  1) Ensure that structural members are not cut  carpeting, tile, etc. 2) Provide adequate clearances for  or weakened during instal
                    
                    Streszczenie treści zawartej na stronie nr. 8 
                    
                        49-7/8"(1267mm) INSTALLATION COMBUSTIBLE  MANTELS FRAMING AND  FINISHING Because of the extreme heat this fi replace  emits, the mantel clearances are critical.  1) Determine the total thickness of facing  Combustible mantel clearances from top of unit  material (e.g. drywall plus ceramic tiles) to  are shown in Diagram below. allow the fi nished surface to be fl ush with  the front of the unit. Total facing thickness  Note: A non-combustible mantel may be  can vary from 1/2" (13mm) to 1" (32mm)  i
                    
                    Streszczenie treści zawartej na stronie nr. 9 
                    
                        INSTALLATION 4) Note:  The unit does not  Facing Over 1" (25mm) Thick have to be completely  enclosed in a chase. The  If the facing material is over 1" (25mm)  thick (example: brick or river  clearance on top of the  rock), install the facing around the perimeter of the face. You may wish  unit is 0" to the standoffs  to make a face template as shown on the diagram. so combustible building  materials can be laid  directly on top of the  FPI offers a cover plate  standoffs. You must  template. S
                    
                    Streszczenie treści zawartej na stronie nr. 10 
                    
                        INSTALLATION OPTIONAL COVER VENTING  UNIT ASSEMBLY  INTRODUCTION PLATE TEMPLATE PRIOR TO  INSTALLATION The  P90  uses  the  "balanced  fl ue"  technology  1) Ensure top clip screws are at top of oblong  Co-axial system. The inner liner vents products  holes before installation. The 2 Top Standoffs must be correctly  of combustion to the outside while the outer liner  positioned and attached to the top before unit  draws outside combustion air into the combustion  Oblong Screw  is slipped into pos
                    
                    Streszczenie treści zawartej na stronie nr. 11 
                    
                        INSTALLATION VENTING FPI Direct  Vent System (Flex) Horizontal Terminations Only These venting systems, in combination with the P90 Direct Vent Gas Fireplace, have been tested and listed as a direct vent heater system by  Warnock Hersey. The location of the termination cap must conform to the requirements in the Vent Terminal Locations diagram in the "Exterior Vent  Termination Locations" section. FPI Direct Vent (Flex) System Termination If a  longer run is needed, the FPI Direct Vent Notes:  K
                    
                    Streszczenie treści zawartej na stronie nr. 12 
                    
                        INSTALLATION EXTERIOR VENT TERMINATION LOCATIONS ® 12 Excalibur P90 Zero Clearance Direct Vent Gas Fireplace A= Clearance above grade, veranda, porch, deck, or balcony *(min. 12"/30cm) H= Not to be installed above a meter/regulator assembly within (3'/90cm) horizontally  B= Clearance to window or door that may be opened *(12"/30cm) #(9"/23cm) from the centerline of the regulator. C= Clearance to permanently closed window *(min. 12"/30cm) J= Clearance to service regulator vent outlet *(min 36"/90
                    
                    Streszczenie treści zawartej na stronie nr. 13 
                    
                        INSTALLATION  RIGID PIPE VENTING COMPONENTS LIST All Simpson Dura-Vent components are available directly from FPI. ® Description     Simpson Dura-Vent     Selkirk            Amerivent               Security ® TM ®            Direct VentGS Direct-Temp          Direct Vent          Secure Vent 6" Pipe Length, Galvanized   908             4DT-6  N/A  SV4L6 6" Pipe Length, Black    908B             4DT-6B  N/A SV4LB6 7" Pipe Length, Galvanized   N/A             N/A   4D7 #N/A 7" Pipe Length, Black  
                    
                    Streszczenie treści zawartej na stronie nr. 14 
                    
                        INSTALLATION RIGID PIPE VENTING SYSTEMS The minimum components required for a basic horizontal termination are: Flat Wall Installation Wall Thickness Vent Length Required   1 Horizontal Termination Cap o (inches) (inches)  1 90 Elbow   1 Rigid Pipe Adaptor  4" -  5-1/2" 6"  1 Wall Thimble 7" -  8-1/2" 9"  1 Length of pipe to suit wall thickness   (see chart)  10" - 1-1/2" 12"  1 4" x 6-5/8" to 5" x 8" increaser for 5" x 8" venting 9" - 14-1/2" 11" - 14-5/8" Adj. Pipe Wall thickness  is measured 
                    
                    Streszczenie treści zawartej na stronie nr. 15 
                    
                        INSTALLATION Horizontal & Vertical Terminations for 5" x 8" Venting ® Excalibur P90 Zero Clearance Direct Vent Gas Fireplace 15                                                                                                                                                                                                                                                                                                                                                                                     
                    
                    Streszczenie treści zawartej na stronie nr. 16 
                    
                        INSTALLATION RIGID PIPE VENTING ARRANGEMENTS - HORIZONTAL TERMINATIONS FPI DIRECT  VENT SYSTEM (FLEX) (Propane & Natural Gas) o o o The diagram shows all allowable combinations of vertical runs with horizontal terminations, using one 90 elbow (two  45 elbows equal one 90  elbow). All Rigid Pipe Systems All Rigid Pipe Systems 4" inner diameter 5" inner diameter 6-5/8" outer diameter 8" outer diameter FPI Flex Vent Note: Must use FPI increaser starter collar 4" inner diameter  (Part # 946-605) at 
                    
                    Streszczenie treści zawartej na stronie nr. 17 
                    
                        INSTALLATION  RIGID PIPE VENTING ARRANGEMENTS - VERTICAL  TERMINATIONS o The shaded area in the diagram shows all allowable combinations of straight vertical and offset to vertical terminations, using two 90 elbow,  with  rigid pipe vent systems for Propane and Natural Gas.  •  Vent must be supported at offsets. •  Firestops are required at each fl oor level and whenever passing through a wall. •  Maintain clearances to combustibles. Note: Must use optional rigid pipe adaptor when using rigid ven
                    
                    Streszczenie treści zawartej na stronie nr. 18 
                    
                        INSTALLATION The P90 is approved for a maximum 40 ft. straight vertical, with rigid pipe  4" x 6-5/8" vent systems for Propane and Natural Gas, as per diagram. The shaded area in the diagram show all allowable combinations of straight  vertical and offset to vertical terminations with rigid pipe vent systems for  o Propane and Natural Gas. Maximum two 45 elbows allowed. •  Vent must be supported at offsets •  Firestops are required at each fl oor level and whenever passing  through a wall. •  Mai
                    
                    Streszczenie treści zawartej na stronie nr. 19 
                    
                        INSTALLATION o Horizontal Venting with Two (2) 90 Elbows Must Use: 5" x 8" Simpson Direct Vent GS Piping with FPI  Increaser Starter Collar (Part #946-605). o o One 90 elbow = Two 45 elbows.  Option     V          H + H1 With these options,       A) 6"  Min.      2' Max. maximum total pipe length       B) 1'  Min.      3' Max. is 30 feet with minimum  of 6 feet total vertical       C) 2'  Min.      4' Max. and maximum 8 feet total       D) 3'  Min.      5' Max. horizontal.      E) 4'  Min.      
                    
                    Streszczenie treści zawartej na stronie nr. 20 
                    
                        INSTALLATION o Vertical Venting with Two (2) 90 Elbows Must Use: 5" x 8" Simpson Direct Vent GS Piping with FPI Increaser  Starter Collar (Part #946-605), unless V1 is greater than or equal to  4'-6" then use 4" x 6-5/8" piping. o o One 90 elbow = Two 45 elbows.  Option V     H V + V1 With these options, max. total  pipe length is 30 feet with min.        A) 0' Min. 2' Max. 1' Min.  of 6 feet total vertical and max.        B) 1' Min. 4' Max. 2' Min.  8 feet total horizontal.       C) 2' Min. 5'