Streszczenie treści zawartej na stronie nr. 1 
                    
                          
COAXIAL MEDIA INTERFACE
MODULE (THN-MIM)
INSTALLATION GUIDE
The Complete Networking Solution™
CABLETRON SYSTEMS, P. O. Box 5005, Rochester, NH 03867-0505                                                                                                                                                                                                                                                                                                                                                        
                    
                    Streszczenie treści zawartej na stronie nr. 2 
                    
                                             NOTICE NOTICE Cabletron Systems reserves the right to make changes in specifications  and other information contained in this document without prior notice.  The reader should in all cases consult Cabletron Systems to determine  whether any such changes have been made. The hardware, firmware, or software described in this manual is  subject to change without notice. IN NO EVENT SHALL CABLETRON SYSTEMS BE LIABLE FOR  ANY INCIDENTAL, INDIRECT, SPECIAL, OR CONSEQUENTIAL  DAMAGE
                    
                    Streszczenie treści zawartej na stronie nr. 3 
                    
                             NOTICE FCC NOTICE This device complies with Part 15 of FCC rules. Operation is subject to  the following two conditions: (1) this device may not cause harmful  interference, and (2) this device must accept any interference received,  including interference that may cause undesired operation. NOTE: This equipment has been tested and found to comply with the  limits for a Class A digital device, pursuant to Part 15 of FCC Rules.  These limits are designed to provide reasonable protection agai
                    
                    Streszczenie treści zawartej na stronie nr. 4 
                    
                                 CONTENTS TABLE OF CONTENTS CHAPTER 1 INTRODUCTION  1.1 INTRODUCTION ........................................................................ 1-1 1.2 USING THIS MANUAL .............................................................. 1-2 1.3 SPECIFICATIONS ...................................................................... 1-2 1.4 RELATED USER MANUALS ..................................................... 1-4 CHAPTER 2 INSTALLATION  2.1 INTRODUCTION .......................................
                    
                    Streszczenie treści zawartej na stronie nr. 5 
                    
                           CONTENTS iv                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                      
                    
                    Streszczenie treści zawartej na stronie nr. 6 
                    
                                  INTRODUCTION CHAPTER 1 INTRODUCTION 1.1 INTRODUCTION Cabletron Systems Coaxial Media Interface Module (THN-MIM)  provides 12 Ethernet/lEEE 802.3 coaxial cable connectors per module.  ™ When used with the MMAC-8 enclosure, up to 84 coaxial segments  ™ can be connected to one MMAC . The THN-MIM can be mixed with other Media Interface Modules to  provide a variety of different media connections. This means that you  can use a combination of twisted pair, fiber optic, and coaxial cabling  
                    
                    Streszczenie treści zawartej na stronie nr. 7 
                    
                                     INTRODUCTION can be connected directly to the module. Each of these segments  supports one device. The entire THN-MIM or each port on the MIM can be controlled via the  IRM in your MMAC. The IRM can be accessed directly through a  console port on the front panel or be controlled and managed in-band  ™ using Cabletron Systems Remote LANVIEW/Windows ,  ® SPECTRUM , or SNMP compliant network control management  software. ® Each port on the THN-MIM has two LANVIEW LEDs, the Port OK  (PO
                    
                    Streszczenie treści zawartej na stronie nr. 8 
                    
                                     INTRODUCTION NOTE: Cabletron Systems reserves the right to change these  specifications at any time without notice. BNC INTERFACE (Ports 1-12) Type: BNC receptacle, with gold center contact,  for use with BNC type plugs and RG-58  thin-net cable. Internal Transceiver: Cabletron Systems TMS-3 Transceiver. For further information, refer to the  TMS-3 Transceiver User's Manual. Terminations: Each segment is internally connected to a  50 ohm terminator in the port. Grounding: Each segme
                    
                    Streszczenie treści zawartej na stronie nr. 9 
                    
                                         INTRODUCTION SAFETY WARNING: It is the responsibility of the person who sells the system of  which the THN-MIM will be a part, to ensure that the total system meets  allowed limits of conducted and radiated emissions. Designed in accordance with UL478, UL910, NEC 725-2(b), CSA, IEC,  TUV, VDE class A. Meets FCC part 15, Class A limits. SERVICE MTBF (MHBK-217D): >156,462 hr. predicted MTTR: <0.5 hr. PHYSICAL Dimensions: 13.4 D x 11.5 H x 2 W inches Weight: 2 lbs. 1.4 RELATED USER
                    
                    Streszczenie treści zawartej na stronie nr. 10 
                    
                                  INSTALLATION  CHAPTER 2  INSTALLATION 2.1 INTRODUCTION The Cabletron Systems THN-MIM is designed for quick and easy  installation into an MMAC. No special skills or tools are required to  install this module. 2.2 NETWORK DESIGN GUIDELINES The following network design guidelines must be followed when  connecting segments to the THN-MIM. If not, unsatisfactory network  performance may result. 2.2.1 Thin-net Segments This applies to the THN-MIM only.  For the THN-MIM7593, see  section 2.2
                    
                    Streszczenie treści zawartej na stronie nr. 11 
                    
                             INSTALLATION Since the ports on the module are internally terminated, the end of  the segment that will be connected to the module will not be a tee  connector or terminator.  2.2.2 Thin-net Segments (THN-MIM7593 only) The following network design guideline must be followed when  connecting 75 or 93 ohm coaxial cable segments to the THN-MIM7593.  If not, unsatisfactory network performance may result. • The length of the 75 or 93 ohm coaxial cable segment is dependent  on signal loss from on
                    
                    Streszczenie treści zawartej na stronie nr. 12 
                    
                             INSTALLATION  • The THN-MIM7593 does not report false collisions to the IRM.  However, if a non-Cabletron Systems Ethernet device is connected  to the segment, it is possible for false collisions to be generated.  Non-Cabletron System devices should be thoroughly tested before  using them with the THN-MIM7593. 2.2.3 Thick-net Segments • 50 ohm Ethernet type coaxial cable must be used when making up  thick-net cable segments. • Each thick-net cable segment connected to a THN-MIM module  must
                    
                    Streszczenie treści zawartej na stronie nr. 13 
                    
                                         INSTALLATION 2.3 INSTALLATION Install the THN-MIM into the MMAC as follows: CAUTION: Observe all electrostatic precautions when handling the  THN-MIM. Static discharges will damage the module. 1. Remove the unit from the shipping box. 2. Slide the two foam end caps off the unit. 3. Remove the unit from the protective plastic bag and set the  THN-MIM in a static free area. Save the shipping box and  materials in case the module has to be reshipped. 4. Slide the module into the MM
                    
                    Streszczenie treści zawartej na stronie nr. 14 
                    
                                         TESTING AND LANVIEW  CHAPTER 3  TESTING AND LANVIEW 3.1 INTRODUCTION This section lists procedures to ensure that the segments connected to  the Cabletron Systems THN-MIM are operating properly. A  description of LANVIEW LEDs and their function in troubleshooting  physical layer network problems are also provided. 3.2 INSTALLATION CHECK-OUT This section contains procedures to test that the physical layer of the  network and a coaxial segment connected to the THN-MIM are  operati
                    
                    Streszczenie treści zawartej na stronie nr. 15 
                    
                                           TESTING AND LANVIEW At least 100 packets should be sent and received with no errors.  The packets will be received from and sent back to the LAN-MD  acting as the SERVER. When the applicable segment(s) connected to the THN-MIM have  successfully completed these tests, the segments are ready for normal  operation. If any failures were noted, please contact Cabletron Systems  Technical Support. 3.3 USING LANVIEW The THN-MIM uses Cabletron Systems built-in visual diagnostic and