QuickSpecs
HP 60 Modular Smart Array HP 60 Modular Smart Array HP 60 Modular Smart Array HP 60 Modular Smart Array
Overview
The HP 60 Modular Smart Array enclosure is a 2U Serial Attach SCSI (SAS) disk drive storage enclosure supporting 3.5 inch SAS,
Serial ATA (SATA) and SAS Midline (MDL) drives. This enclosure delivers industry-leading data performance, availability, storage
density, and upgradeability to meet customers' demanding and growing storage needs. This enclosure is designed to supp
Streszczenie treści zawartej na stronie nr. 2
QuickSpecs HP 60 Modular Smart Array HP 60 Modular Smart Array HP 60 Modular Smart Array HP 60 Modular Smart Array Overview Front panel LEDs and buttons Front panel LEDs and buttons Front panel LEDs and buttons Front panel LEDs and buttons 1. Heartbeat LED 2. Fault LED 3. UID button/LED Rear Panel components Rear Panel components Rear Panel components Rear Panel components 1. Power Supply 1 6. I/O module bay 2. System fan 1 7. I/O module bay 3. Dual 7 segment display board (for future
Streszczenie treści zawartej na stronie nr. 3
QuickSpecs HP 60 Modular Smart Array HP 60 Modular Smart Array HP 60 Modular Smart Array HP 60 Modular Smart Array Overview At A Glance At A Glance At A Glance At A Glance 2U rackmount form factor 3 Gb/s SAS host connectivity Dual Domain support with HP Smart Array P800 Controller for HP ProLiant and Integrity servers (requires dual port SAS drives) Multi Initiator support with the SC44Ge Host Bus Adapter (AH303A) (HP-UX and Open VMS on selected HP Integrity Servers) with dual port SAS drives on
Streszczenie treści zawartej na stronie nr. 4
QuickSpecs HP 60 Modular Smart Array HP 60 Modular Smart Array HP 60 Modular Smart Array HP 60 Modular Smart Array Standard Features Modular Smart Array Modular Smart Array Modular Smart Array Modular Smart Array The HP Modular Smart Array family delivers simple, affordable storage technology to meet today's Family Family Family Family demanding and growing IT needs. These storage solutions offer the best price/performance and best price/availability features for direct attach environments, smal
Streszczenie treści zawartej na stronie nr. 5
QuickSpecs HP 60 Modular Smart Array HP 60 Modular Smart Array HP 60 Modular Smart Array HP 60 Modular Smart Array Standard Features NOTE: NOTE: NOTE: NOTE: Customer must be running HP Systems Insight Manager in order to qualify for Pre-Failure warranty. The enclosure is only covered for the warranty period of the drive (3 years for SAS and 1 year for SAS Midline (MDL) and SATA drives). DA - 12627 North America — Version 37 — June 8, 2011 Page 5
Streszczenie treści zawartej na stronie nr. 6
QuickSpecs HP 60 Modular Smart Array HP 60 Modular Smart Array HP 60 Modular Smart Array HP 60 Modular Smart Array Product Highlights High Levels of Storage High Levels of Storage High Levels of Storage High Levels of Storage Storage Capacity Storage Capacity Storage Capacity Storage Capacity - The MSA60 enclosure supports up to 12 SAS drives for a maximum capacity Density, Data Protection, Density, Data Protection, Density, Data Protection, Density, Data Protection, of 7.2 TB SAS drives or 24 T
Streszczenie treści zawartej na stronie nr. 7
QuickSpecs HP 60 Modular Smart Array HP 60 Modular Smart Array HP 60 Modular Smart Array HP 60 Modular Smart Array MSA60 Components MSA60 Enclosure MSA60 Enclosure MSA60 Enclosure MSA60 Enclosure The 2U array houses up to twelve 3.5 inch Universal hot pluggable SAS or SATA drives. Each MSA60 includes the following standard components: MSA60 base enclosure with redundant power supplies and fan modules Rack mounting hardware kit 0.5m mini-SAS cable Two AC power cords and two PDU interconnect cords
Streszczenie treści zawartej na stronie nr. 8
QuickSpecs HP 60 Modular Smart Array HP 60 Modular Smart Array HP 60 Modular Smart Array HP 60 Modular Smart Array MSA60 Components Smart Array P812 Smart Array P812 Smart Array P812 Smart Array P812 The HP Smart Array P812 provides superior RAID performance, while delivering high levels of Features Features Features Features connectivity, reliability, and many advanced features Increased connectivity with 8 internal ports and 16 external ports. 1 G 72-bit wide DDR2-800 flash-backed write cache
Streszczenie treści zawartej na stronie nr. 9
QuickSpecs HP 60 Modular Smart Array HP 60 Modular Smart Array HP 60 Modular Smart Array HP 60 Modular Smart Array Software Components Utilities Utilities Utilities Utilities The MSA60 utilizes a single, consistent set of utility software for storage and RAID management, setup, configuration and troubleshooting. This consistency reduces the cost of ownership by reducing the training and technical expertise necessary to install and maintain your HP server storage solution. Configuration Utilities
Streszczenie treści zawartej na stronie nr. 10
QuickSpecs HP 60 Modular Smart Array HP 60 Modular Smart Array HP 60 Modular Smart Array HP 60 Modular Smart Array Service and Support, HP Care Pack, and Warranty Information Service and Support Service and Support Service and Support Service and Support Three-year limited parts only warranty, including hardware diagnostic support, pre-failure warranty (coverage of hard drives, memory and processors). The warranty is fully supported by HP Services and a worldwide network of resellers and service
Streszczenie treści zawartej na stronie nr. 11
QuickSpecs HP 60 Modular Smart Array HP 60 Modular Smart Array HP 60 Modular Smart Array HP 60 Modular Smart Array Service and Support, HP Care Pack, and Warranty Information HA110A3-87G HA111A3-87G HA112A3-87G 4 Year Support HA101A4-87G HA103A4-87G HA104A4-87G HA105A4-87G HA109A4-87G HA110A4-87G HA111A4-87G HA112A4-87G 5 Year Support HA101A5-87G HA103A5-87G HA104A5-87G HA105A5-87G HA109A5-87G HA110A5-87G HA111A5-87G HA112A5-87G Installation & Start-Up HA113A1-564 Fixed Care Packs Fixed Care Pac
Streszczenie treści zawartej na stronie nr. 12
QuickSpecs HP 60 Modular Smart Array HP 60 Modular Smart Array HP 60 Modular Smart Array HP 60 Modular Smart Array Configuration Information Step 1: Base Configuration Step 1: Base Configuration Step 1: Base Configuration Step 1: Base Configuration Model Model Model Model Shipping Dimensions Shipping Dimensions Shipping Dimensions Shipping Dimensions Part Number Part Number Part Number Part Number MSA60 MSA60 MSA60 MSA60 HP 60 Modular Smart Array 418408-B21 I/O Module I/O Module I/O Module I/O M
Streszczenie treści zawartej na stronie nr. 13
QuickSpecs HP 60 Modular Smart Array HP 60 Modular Smart Array HP 60 Modular Smart Array HP 60 Modular Smart Array Configuration Information Step 2: Array Controllers Step 2: Array Controllers Step 2: Array Controllers Step 2: Array Controllers Description Description Description Description Part Number Part Number Part Number Part Number Smart Array Controllers Smart Array Controllers Smart Array Controllers Smart Array Controllers HP ProLiant Servers HP ProLiant Servers HP ProLiant Servers HP
Streszczenie treści zawartej na stronie nr. 14
QuickSpecs HP 60 Modular Smart Array HP 60 Modular Smart Array HP 60 Modular Smart Array HP 60 Modular Smart Array Configuration Information Step 3: Choose HP ProLiant Server(s)/HP Integrity Server(s) Step 3: Choose HP ProLiant Server(s)/HP Integrity Server(s) Step 3: Choose HP ProLiant Server(s)/HP Integrity Server(s) Step 3: Choose HP ProLiant Server(s)/HP Integrity Server(s) Server Compatibility Server Compatibility Server Compatibility Server Compatibility HP ProLiant Servers HP ProLiant Ser
Streszczenie treści zawartej na stronie nr. 15
QuickSpecs HP 60 Modular Smart Array HP 60 Modular Smart Array HP 60 Modular Smart Array HP 60 Modular Smart Array Configuration Information NOTE: NOTE: NOTE: NOTE: Go to the HP Hard Drive Compatibility table for complete drive compatibility information (http://www.hp.com/products/harddiskdrives). Using hard drives in unsupported configurations will result in voiding the warranty and could result in damage to the drive and/or loss of data. Step 5: Choose Rack Option Step 5: Choose Rack Option
Streszczenie treści zawartej na stronie nr. 16
QuickSpecs HP 60 Modular Smart Array HP 60 Modular Smart Array HP 60 Modular Smart Array HP 60 Modular Smart Array Technical Specifications LED Indicators for HDDs LED Indicators for HDDs LED Indicators for HDDs LED Indicators for HDDs Online (bottom) Drive Failure/ID (top) LED Indicators on Front LED Indicators on Front LED Indicators on Front LED Indicators on Front Heartbeat LED Panel Panel Panel Panel Fault LED UID button/LED LED Indicators on Rear LED Indicators on Rear LED Indicators on Re
Streszczenie treści zawartej na stronie nr. 17
QuickSpecs HP 60 Modular Smart Array HP 60 Modular Smart Array HP 60 Modular Smart Array HP 60 Modular Smart Array Technical Specifications © Copyright 2011 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. The only warranties for HP products and services are set forth in the express warranty statements accompanying such products and services. Nothing herein should be construed as constituting an additional warranty. HP shall not be l