Краткое содержание страницы № 1
IP Enabling Siemens Hicom 300
With Avaya Solutions Running
MultiVantage™ Software
Configuring a PRI Trunk Connection between an Avaya S8300
Media Server and an Avaya G700 Media Gateway running
Avaya MultiVantage™ Software and a Siemens Hicom 300.
Issue 1.0
ABSTRACT
Many multi-location enterprises have telecommunications equipment from
vendors that do not provide a gentle migration path to IP converged platforms.
Avaya’s Enterprise Class IP Solutions (ECLIPS) enable a gradual adop
Краткое содержание страницы № 2
1. Introduction: The configuration shown in figure 1 illustrates a PRI Trunk Connection between an Avaya S8300 Media Server and an Avaya G700 Media Gateway (S8300/G700) running Avaya MultiVantage Software placed as an adjunct to a Siemens Hicom 300. The main Central Office connection for the solution is made through the Siemens Hicom 300. Additional Central Office lines can be connected to the S8300/G700 in order to facilitate the use of Avaya™ Extension to Cellular (EC500) and other Avaya Multi
Краткое содержание страницы № 3
2. Equipment and Software Validated: The configuration used to test performance of this solution was established in an Avaya Lab setting within the guidelines and use parameters allowed in the user licenses acquired with the equipment and software listed below. Platform Version Avaya MultiVantage Software 1.2 Avaya S8300 Media Server 213.0 Avaya G700 Media Gateway 3.12 Avaya™ 4612 IP Phones 46XXCommon.V36 Avaya™ 4624 IP Phones 46XXCommon.V36 Avaya MM710 T-1 Interface Firmware version 5 Siemens H
Краткое содержание страницы № 4
Software: 1. Recommended Siemens Hicom 300. Release 9006.5 or newer. 2. Firmware for the boards and phones are included in the core software. Hardware: 1. TNBN64P and TNDN64 can be programmed to run PRI and NI2. 2. TMDN TMD24 can only be used with PRI. Board type used is dependant on software and hardware release of the switch. 4. Cable schematic: Note: A length of 4-wire cable is needed to make the connection to each PRI circuit card. The Pin assignments for each are as follows. Siemens TMDN
Краткое содержание страницы № 5
Figure 2a. MM710 DS1 Circuit Pack Administration Figure 2b. MM710 DS1 Circuit Pack Administration Jsl © 2002 Avaya Inc All Rights Reserved IP Enabling Siemens Hicom with Avaya MultiVantage Solutions LPH 11-27-02 5
Краткое содержание страницы № 6
Trunk Group: Create a Trunk Group and select “isdn” as the Group Type and a TAC number based on your switches dial-plan. Ensure “PRI/BRI” is the Carrier Medium, this is used for ISDN trunks. Set Dial Access to “Y” and Service type is “tie”, this gives the most universal type of connection. All other prompts are default. Figure 4. Trunk–Group Administration Signaling Group: Create a Signaling Group for the PRI D-channel. The Group Type default is “isdn-pri”; this creates a channel to contro
Краткое содержание страницы № 7
Trunk Group Members: Assign trunk ports to the Trunk Group. Up to 255 ports can be assigned to each ISDN Trunk Group. The Sig Grp prompt will display the signaling group after the Trunk Group is created and assigned to the Signaling Group. Figure 5. Assign trunk Group Members 6. Hicom Configurations: The following listing of Command Line Interface (CLI) text is intended to be an accurate representation of the actual administrative visuals for implementing the translations required for the Hic
Краткое содержание страницы № 8
Determine If System Has Capacities:
Краткое содержание страницы № 9
Adding a TNDN64 T-1 Board:
Краткое содержание страницы № 10
ACKTIM = ? ACKTIM : ACKNOWLEDGEMENT TIMER CHARACTERISTIC : OPTIONAL POSSIBLE VALUES : 1000-5000 ACKTIM =1000 DLVTIM = ? DLVTIM : DATA LINK VERIFICATION TIMER CHARACTERISTIC : OPTIONAL POSSIBLE VALUES : 5000-60000 DLVTIM =30000 OCTMAX = ? OCTMAX : MAXIMUM NUMBER OF OCTETS IN AN INFORMATION FIELD CHARACTERISTIC : OPTIONAL POSSIBLE VALUES : 3-260 OCTMAX =260 RETMAX = ? RETMAX : MAXIMUM NUMBER OF RETRANSMISSIONS CHARACTERISTIC : OPTIONAL POSSIBLE VALUES : 1-10
Краткое содержание страницы № 11
SET UP - OUT OF SERVICE (NPR) H6 : THE CIRCUIT WAS ADDED TO THE REFERENCE CLOCK TABLE. H19 : WHEN FCTID IS NOT ENTERED, OR FCTID=0 IS ENTERED FOR A TMDN, IT WILL CONFIGURE A TMDN WITH THE DEFAULT FCTID=1. AMO-BCSU -111 BOARD CONFIGURATION, SWITCHING UNIT ADD COMPLETED; Display Board:
Краткое содержание страницы № 12
Add Trunk Group Access Codes:
Краткое содержание страницы № 13
CFBLOCK = ? CFBLOCK : CALL FORWARD BLOCKING CHARACTERISTIC : OPTIONAL POSSIBLE VALUES : ENABLED CALL FORWARD BLOCKING ENABLED DISABLED CALL FORWARD BLOCKING DISABLED CFBLOCK = DISABLED ADD-TGACC:100,NONE,C-HAWK,23,BOTH,TERR,,,0,ROUND,; H500: AMO TGACC STARTED H1: TRUNK GROUP 100 HAS BEEN CREATED AMO-TGACC-111 TRUNK GROUP ACCESS CODE ADD COMPLETED; Display Trunk Group Access Codes:
Краткое содержание страницы № 14
Display COP (Class of Parameters):
Краткое содержание страницы № 15
Add COS (Class of Service):
Краткое содержание страницы № 16
MDR MESSAGE/CALL DETAIL RECORDING ORIGONLY ORIGINATE ONLY TERMLPBK DATA REMOTE TERMINAL LOOPBACK URTA UNRESTRICTED TRUNK ACCESS TO AND FROM CO ADTE = AFAX = DVCE = ? DVCE : DELETE VOICE AUTHORIZATION CHARACTERISTIC : OPTIONAL POSSIBLE VALUES : AGENT ACD AGENT AUTOLOG ACD AUTOLOGON BROADCST SPEAKER CALL DIAL ONE WAY BROADCAST
Краткое содержание страницы № 17
Display COS (Class of Service):
Краткое содержание страницы № 18
TCCID = ? TCCID : TELEPHONE COMPANY CIRCUIT IDENTIFICATION CHARACTERISTIC : OPTIONAL POSSIBLE VALUES : MAX. OF 30 POSITIONS TCCID = 123456 DEV = ? DEV : DEVICE TYPE (DEVICE HANDLER)/MODULE TYPE CHARACTERISTIC : REQUIRED CONDITIONAL POSSIBLE VALUES : ATMPBB ATM INTERWORKING B-CHANNEL ATMIWB ATM INTERWORKING B-CHANNEL T1GRDSTR T1 TRUNK EMULATING GROUND-START TRUNK GRDSTR GROUND-START TR
Краткое содержание страницы № 19
COSNO = 1 DEDSVC = ? DEDSVC : DEDICATED SERVICE FOR PRIB TRUNKS CHARACTERISTIC : OPTIONAL CONDITIONAL POSSIBLE VALUES : NONE NOT A SPECIAL DEVICE TTA TIE TRUNK ACCESS FX FOREIGN EXCHANGE ACCESS SERVICE PRIV PRIVATE NETWORK SERVICE MCI8 MCI 800 MCIP MCI PRISM-1 MCIV MCI VNET WB9 WATS
Краткое содержание страницы № 20
Modify D-Channel from Default: