Краткое содержание страницы № 1 
                    
                        INSTALLATION INSTRUCTIONS
30" (76.2 CM) FREESTANDING GAS RANGES
with standard clean oven
Table of Contents
RANGE SAFETY............................................................................. 2
INSTALLATION REQUIREMENTS................................................ 3
Tools and Parts............................................................................ 3
Location Requirements................................................................ 3
Electrical Requirements....................
                    
                    Краткое содержание страницы № 2 
                    
                        RANGE SAFETY Your safety and the safety of others are very important. We have provided many important safety messages in this manual and on your appliance. Always read and obey all safety  messages. This is the safety alert symbol. This symbol alerts you to potential hazards that can kill or hurt you and others. All safety messages will follow the safety alert symbol and either the word “DANGER” or “WARNING.” These words mean: You can be killed or seriously injured if you don't immediately  DANG
                    
                    Краткое содержание страницы № 3 
                    
                        WARNING Tip Over Hazard A child or adult can tip the range and be killed. Connect anti-tip bracket to rear range foot. Reconnect the anti-tip bracket, if the range is moved. Failure to follow these instructions can result in death or serious burns to children and adults. INSTALLATION REQUIREMENTS Tools and Parts Location Requirements Gather the required tools and parts before starting installation. IMPORTANT: Observe all governing codes and ordinances. Do  Read and follow the instructions provid
                    
                    Краткое содержание страницы № 4 
                    
                        Mobile Home - Additional Installation Requirements Cabinet Dimensions The installation of this range must conform to the Manufactured  Home Construction and Safety Standard, Title 24 CFR, Part 3280  Cabinet opening dimensions shown are for 25" (64.0 cm)  (formerly the Federal Standard for Mobile Home Construction  countertop depth, 24" (61.0 cm) base cabinet depth and and Safety, Title 24, HUD Part 280). When such standard is not  36" (91.4 cm) countertop height. applicable, use the Standard for
                    
                    Краткое содержание страницы № 5 
                    
                        Electrical Requirements Gas Supply Requirements WARNING WARNING Explosion Hazard Electrical Shock Hazard Use a new CSA International approved gas supply line. Plug into a grounded 3 prong outlet. Install a shut-off valve. Do not remove ground prong. Securely tighten all gas connections. Do not use an adapter. If connected to LP, have a qualified person make sure  Do not use an extension cord. gas pressure does not exceed 14" (36 cm) water  Failure to follow these instructions can result in death
                    
                    Краткое содержание страницы № 6 
                    
                        Gas Supply Line Gas Pressure Regulator ■ Provide a gas supply line of ¾" (1.9 cm) rigid pipe to the The gas pressure regulator supplied with this range must be  range location. A smaller size pipe on longer runs may result used. The inlet pressure to the regulator should be as follows for  in insufficient gas supply. With LP gas, piping or tubing size proper operation: can be ½" (1.3 cm) minimum. Usually, LP gas suppliers  Natural gas: determine the size and materials used in the system. Minimum
                    
                    Краткое содержание страницы № 7 
                    
                        INSTALLATION INSTRUCTIONS 2. Place template on the floor in cabinet opening so that the left  edge is against cabinet and top edge is against rear wall,  Unpack Range molding or cabinet.  3. Tape template into place. WARNING 4. If countertop is not flush with cabinet opening edge, align  template with overhang. Excessive Weight Hazard Use two or more people to move and install range. Failure to do so can result in back or other injury. 1. Do not use oven door handle to lift or move the range 2. 
                    
                    Краткое содержание страницы № 8 
                    
                        7. Move range close enough to the opening to allow for final  electrical connection. Remove shipping base, cardboard or  Make Gas Connection hardboard from under range. 8. Open the broiler door. Use a ³⁄₈" drive ratchet to lower the rear  leveling legs one-half turn. Use a wrench or pliers to lower the  WARNING front leveling lets one-half turn. B A Explosion Hazard Use a new CSA International approved gas supply line. A. Rear leveling leg B Front leveling leg Install a shut-off valve. Securely 
                    
                    Краткое содержание страницы № 9 
                    
                        3. Use a combination wrench and pliers to attach the flexible  5. Close the broiler door. connector to the adapters. Check that connector is not  6. Remove cooktop burner caps and grates from parts  kinked.    package. Align notches in burner caps with pins in burner  A base. Burner caps should be level when properly positioned.  If burner caps are not properly positioned, surface burners  B will not light. Place burners, burner caps and grates on the  cooktop. D WARNING C F E G Electrical Shock
                    
                    Краткое содержание страницы № 10 
                    
                        Electronic Ignition System Initial lighting and gas flame adjustments If the low flame needs adjusting: Cooktop and oven burners use electronic igniters in place of 1. Turn control knob to the “Lo” setting and remove control  standing pilots. When the cooktop control knob is turned to the knob. “LITE” position, the system creates a spark to light the burner.  2. Insert a small flat-blade screwdriver into the valve stem. Turn  This sparking continues until the control knob is turned to the  the v
                    
                    Краткое содержание страницы № 11 
                    
                        If the flame needs adjusting: 1. Turn the oven off. Wait for the oven burner to cool down. Complete Installation 2. Open oven door and remove oven racks, oven tray, flame 1. Check that all parts are now installed. If there is an extra part,  spreader and set aside. go back through the steps to see which step was skipped. 2. Check that you have all of your tools. A 3. Dispose of/recycle all packaging materials. 4. Check that the range is level. See “Level Range.” A 5. Use a mild solution of liqui
                    
                    Краткое содержание страницы № 12 
                    
                        GAS CONVERSIONS 2. Unplug range or disconnect power. 3. Open broiler door and remove broiler pan. The gas pressure  WARNING regulator is located in the back right hand corner of the broiler  compartment. A Explosion Hazard Use a new CSA International approved gas supply line. Install a shut-off valve. Securely tighten all gas connections. A. Gas pressure regulator If connected to LP, have a qualified person make sure  gas pressure does not exceed 14" (36 cm) water  IMPORTANT: Do not remove the g
                    
                    Краткое содержание страницы № 13 
                    
                        For models with 3 standard burners and 1 power burner: To Convert Surface Burners 1. Remove burner grate, burner caps and burners.  A Std burner 88 Std burner 88 Power burner 96 Std burner 88 B 5. Place the Natural gas orifice spuds in the parts bag for future  use and keep with the bag containing literature. 6. Reinstall burners, burner caps and burner grates. A. Burner cap To Convert Oven Burner B. Burner 1. Open the oven door and remove oven racks, oven tray, flame  2. Locate LP gas orifice s
                    
                    Краткое содержание страницы № 14 
                    
                        3. Open broiler door and remove broiler pan. The gas pressure  regulator is located in the back right hand corner of the broiler  Complete Conversion compartment. 1. Refer to the “Make Gas Connection” section for properly  connecting the range to the gas supply. A 2. Turn the manual shutoff valve in the gas supply line to the  open position. 3. Refer to “Check Operation” in the “Electronic Ignition  System” section for proper burner ignition, operation and  burner flame adjustments. IMPORTANT: Y
                    
                    Краткое содержание страницы № 15 
                    
                        For models with 3 standard burners and 1 power burner: To Convert  Surface Burners 1. Remove burner grate, burner caps and burners.  A Std Burner 149 Std Burner 149 Std Burner 149 Power Burner 165 B 5. Place LP gas orifice spuds in the parts bag for future use and  keep with the bag containing literature. 6. Reinstall burners, burner caps and burner grates. A. Burner cap To Convert Oven Burner B. Burner 1. Open the oven door and remove oven racks, oven tray, flame  2. Locate the Natural gas orif
                    
                    Краткое содержание страницы № 16 
                    
                        W10032050B © 2009. 9/09 All rights reserved. Printed in Mexico