Краткое содержание страницы № 1 
                    
                        Installation  
Operation 
Maintenance
Split System Cooling or  
Heat Pump Air Handler 
7½ - 20 Tons
Model TWE
Models (60 Hz) Models (50 Hz)
TWE060A***E TWE050AD**E
TWE060B***E TWE075AD**E
TWE090A***E TWE100AD**E
TWE090B***E TWE100BD**E
TWE120A***F TWE155BD**E
TWE120B***E TWE200BD**F
TWE180B***E
TWE240B***F
October 2006 TWE-SVX03C-EN                                                                                                                                                                      
                    
                    Краткое содержание страницы № 2 
                    
                        Preface and Warnings and Cautions Literature Change History Warnings and Cautions TWE-SVX03A-EN (June 2003)  Notice that warnings and cautions  Implemented Global Graphics format  appear at appropriate intervals  to IOM. throughout this manual. Warnings  TWE-SVX03B-EN (April 2005)  are provided to alert installing  Added capacitor discharge warning. contractors to potential hazards that  could result in personal injury or  TWE-SVX03C-EN (September 2006)  death, while cautions are designed to  Mo
                    
                    Краткое содержание страницы № 3 
                    
                        Contents Model Number Description  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 General Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Installation Checklist . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Unit Inspection  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Inspection 
                    
                    Краткое содержание страницы № 4 
                    
                        Model Number Description TWE 090 A 1 00 E A 123 456 7 8 9 10 11 12 DIGITS 1-3: PRODUCT TYPE DIGIT 8: ELECTRICAL  Model Number Description CHARACTERISTICS TWE = Split System Heat Pump/ All products are identified by a  Cooling Air Handler 1 = 208-230/60/1 multiple-character model number  that precisely identifies a particular 3 = 208-230/60/3 DIGITS 4-6: NOMINAL GROSS  type of unit. An explanation of the  4 = 460/60/3 COOLING CAPACITY (MBh) alphanumeric identification code is  W = 575/60/3 060 = 
                    
                    Краткое содержание страницы № 5 
                    
                        General Information Installation procedures should be  General  Unit Inspection performed in the sequence that they  This manual covers installation of Inspect material carefully for any  appear in this manual. Do not  the TWE050, 060, 075, 090,100 and  shipping damage. If damaged, it  destroy or remove the manual from  120A single circuit air handlers and  must be reported to, and claims  the unit. TWE060, 075, 090, 100, 120, 155, 180, made against the transportation  200 and 240B dual circuit 
                    
                    Краткое содержание страницы № 6 
                    
                        Unit Dimensions Unit Dimensions Figure 1. 6 TWE-SVX03C-EN                                                                                                                                                                                                                                                                                                                                                                                                                                                           
                    
                    Краткое содержание страницы № 7 
                    
                        Unit Dimensions Figure 1. (continued from previous page) TWE-SVX03C-EN 7                                                                                                                                                                                                                                                                                                                                                                                                                                            
                    
                    Краткое содержание страницы № 8 
                    
                        Unit Dimensions Figure 2. 8 TWE-SVX03C-EN                                                                                                                                                                                                                                                                                                                                                                                                                                                                           
                    
                    Краткое содержание страницы № 9 
                    
                        Unit Dimensions Figure 3. TWE-SVX03C-EN 9                                                                                                                                                                                                                                                                                                                                                                                                                                                                           
                    
                    Краткое содержание страницы № 10 
                    
                        Installation Installation Preparations Process for Drain Pan Relocation The final position for the air handler 1. Remove the access plate at the  must be dictated by required service opposite end of the drain  access to it, weight distribution over connection. This plate secures  structural supports, and by the and lifts the back end of the  locations of electrical, refrigerant drain pan for sloping. It must be  and condensate drainage removed before the drain pan  connections. After this is can
                    
                    Краткое содержание страницы № 11 
                    
                        Installation The crated unit can be moved using a  Refrigerant Piping Preparation Caution  forklift of suitable capacity. For lifting  System Component Damage! The air handler is designed so that  the unit into an elevated mounting  Properly insulate all refrigerant gas  refrigerant piping can enter from  position, run lifting straps or slings  piping to prevent possible water  either the right or left hand side. It is  under the unit and attach securely to  damage due to condensation and to  sh
                    
                    Краткое содержание страницы № 12 
                    
                        Installation be installed, but should not be contains two (2) brass clamps  Caution  connected to the primary drain line (straps) and cork impregnated  Equipment Damage! from the unit. Isolate the auxiliary insulation material approximately 9"  Before hanging the unit on  drain pan from both the air handler long by 4" wide. This is for attaching  suspension rods, reinforce the  and the structure. and insulating the expansion valve  cabinet around the knockouts by  bulb(s) to the suction line(s).
                    
                    Краткое содержание страницы № 13 
                    
                        Installation Note: Important! When air handler filter track to increase the width of the   WARNING  is installed in the vertical filter opening. Hazardous Voltage  position and close proximity  w/Capacitors! trapping of condensate is  Duct Connections Disconnect all electric power,  required, use of a subbase  The supply and return ducts should including remote disconnects and  accessory to raise the air  be connected to the unit with flame discharge all motor start/run  handler for clearance o
                    
                    Краткое содержание страницы № 14 
                    
                        Installation � Inspect duct outlets. Outlets  WARNING  must be open and unrestricted. Hazardous Voltage! � Inspect unit drain lines. Pipe  Disconnect all electric power,  connections must be tight and  including remote disconnects before  drain line unrestricted. servicing. Follow proper lockout/ � Inspect fan assembly to insure all  tagout procedures to ensure the  moving parts move freely. power can not be inadvertently  energized. Failure to disconnect  � If unit is horizontally mounted,  po
                    
                    Краткое содержание страницы № 15 
                    
                        Field Wiring Thermostat and Control   Connections 1. Observe all notes on the  diagrams. 2. Mount the thermostat in the  desired location. 3. Install color coded low voltage  cables between outdoor unit,  indoor unit and thermostat. 4. Connect low voltage control  wiring to the low voltage  terminal board located on the  side of the fan control box per  the typical interconnecting  wiring diagrams on pages 13  through 22. TTA090A/TWE090A  TTA120A/TWE120A Field Wiring: a. 3 power wires. Line volt
                    
                    Краткое содержание страницы № 16 
                    
                        Field Wiring b. 3 power wires. Line voltage  (2) TW_030/TWE060B  for 3 phase; 2 wires for single  (2) TW_060/TWE120B phase. Field Wiring: c. Heat pump thermostat: 6  a. 3 power wires. Line voltage  wires, 24 volts.  for 3 phase; 2 wires for single  i. Electric heat: add 2  phase. additional wire, 24 volts. b. 3 power wires. Line voltage  d. 2 wires, 24 volts. for 3 phase; 2 wires for single  i. Outdoor thermostat; add  phase. 1 additional wire, 24 volts. c. Heat pump thermostat: 7  ii. Electric 
                    
                    Краткое содержание страницы № 17 
                    
                        Field Wiring Figure 11. TTA090A, 120A/TWE090A, 120A; TTA075A, 100A/TWE075A, 100A Figure 12. TTA120B/TWE120B; TTA120C/TWE120A; TTA100B/TWE100B; TTA100C/TWE100A TWE-SVX03C-EN 17                                                                                                                                                                                                                                                                                                                                     
                    
                    Краткое содержание страницы № 18 
                    
                        Field Wiring Figure 13. TWA090A, 120A/TWE090A, 120A; TWA075A, 100A/TWE075A, 100A Figure 14. TTA120B/TWE120B; TTA120C/TWE120A; TTA100B/TWE100B; TTA100C/TWE100A 18 TWE-SVX03C-EN                                                                                                                                                                                                                                                                                                                                     
                    
                    Краткое содержание страницы № 19 
                    
                        Field Wiring Figure 15. TTA090A, 120A/TWE090A, 120A; TTA075A, 100A/TWE075A, 100A Figure 16. TW_060/TWE060; TW_050/TWE050 TWE-SVX03C-EN 19                                                                                                                                                                                                                                                                                                                                                                           
                    
                    Краткое содержание страницы № 20 
                    
                        Field Wiring Figure 17. TW_060/TWE060; TW_050/TWE050 Figure 18. TW_060/TWE060; TW_050/TWE050 20 TWE-SVX03C-EN