30005_CLRCO2075_UM_Cover.qxd 8/22/03 4:27 PM Page 2 U-LINE CORPORATION LIMITED WARRANTY U-Line Corporation warrants each U-Line product to be free from defects in materials and workmanship for a period of one year from the date of purchase; and warrants the sealed system (consisting of the compressor, the condenser, the evaporator, the hot gas bypass valve, the dryer and the connecting tubing) in each U-Line product to be free from defects in materials and workmanship for a period of five yea
Краткое содержание страницы № 3
30005_CLRCO2075 User Manual 8/22/03 4:23 PM Page 1 INTRODUCTION Congratulations on your purchase of U-Line CLRCO2075 Combination Ice Maker/Refrigerator. A pioneer in the field for nearly 40 years, U-Line is the world’s number one manufacturer of built-in, under- counter ice making and specialty refrigeration products. U-Line dedi- cates 100% of its research and development to these products. The result: U-Line technology leads the market with innovation, design, depth of product line and perf
Краткое содержание страницы № 4
30005_CLRCO2075 User Manual 8/22/03 5:07 PM Page 2 User’s Manual If you do not return your Product Registration Card, U-Line will use the date of sale to the U-Line distributor as the first date of warranty for your unit. Please also record the purchase date of your U-Line unit and your dealer’s name, address and telephone number. Model Number: ________________________________________ Serial Number: ________________________________________ Purchase Date: _____________________________________
Краткое содержание страницы № 5
30005_CLRCO2075 User Manual 8/22/03 4:24 PM Page 3 SAFETY PRECAUTIONS Do not attempt to install or operate your unit until you have read the safety precautions in this manual. Safety items throughout this manual are labeled with a Danger, Warning or Caution based on the risk type. DEFINITIONS This is the safety alert symbol. It is used to alert you to ! potential personal injury hazards. Obey all safety messages that follow this symbol to avoid possible injury or death. DANGER ! ! DANGER indi
Краткое содержание страницы № 6
30005_CLRCO2075 User Manual 8/22/03 4:24 PM Page 4 User’s Manual GENERAL PRECAUTIONS DANGER ! ! RISK OF CHILD ENTRAPMENT. Before you throw away your old refrigerator or freezer, take off the doors and leave shelves in place so that children may not easily climb inside. WARNING ! •Never attempt to repair or perform maintenance on the unit until the electricity has been disconnected. • Altering, cutting of power cord, removal of power cord, removal of power plug, or direct wiring can cause seri
Краткое содержание страницы № 7
30005_CLRCO2075 User Manual 8/22/03 4:24 PM Page 5 PRODUCT DIMENSIONS 24" 23-15/16" (61) (60.8) 34-1/8" (86.7) FULL RETRACT HEIGHT WATER VALVE WATER WATER CONNECTION 21-3/4" DRAIN (55.2) CLRCO001 Figure 1 DRAIN INSTALLATION PLEASE READ all instructions completely before attempting to install or operate the unit. All Ice Makers require a con- nection to the water supply and improper hook-up can result in substantial property damage! All water and drain connections MUST BE made by a licensed/
Краткое содержание страницы № 8
30005_CLRCO2075 User Manual 8/22/03 4:24 PM Page 6 User’s Manual The CLRCO2075 can be installed using a gravity drain or can use a factory installed or equivalent drain pump. Follow these guidelines when installing drain lines to prevent water from flowing back into the ice maker storage bin and/or potentially flowing onto the floor causing water damage: Gravity Drain • Drain lines must have a 5/8 inch inside diameter. • Drain lines must have a 1 inch drop per 48 inches of run (1/4 inch per
Краткое содержание страницы № 9
30005_CLRCO2075 User Manual 8/22/03 4:24 PM Page 7 3. Remove screws securing back panel. 4. Check that the clamps and hose connections (Figure 3) are tight at the following areas: • Discharge tube (A) • Drain tube (B) • Vent tube (C) B B C A BACK VIEW SIDE VIEW CLRCO003 Figure 3 5. Place a suitable container beneath the pump’s discharge tube. (The bucket must be able to hold a minimum of one gallon.) WARNING ! Back panel serves as a guard. DO NOT remove the back panel unless it is to be se
Краткое содержание страницы № 10
30005_CLRCO2075 User Manual 8/22/03 4:24 PM Page 8 User’s Manual CONNECTING A DRAIN PUMP If a gravity drain connection is not available, and you have not purchased the CLRCO2075 with factory installed pump, we strong- ly recommend the use of the U-Line P60 drain pump. The U-Line P60 drain pump is available through your Dealer, or direct from U-Line with complete installation instructions. If a pump other than the U-Line P60 drain pump is to be used, it must meet the following specifica- tion
Краткое содержание страницы № 11
30005_CLRCO2075 User Manual 8/22/03 4:24 PM Page 9 SITE PREPARATION 1. Position the unit on a flat, level surface, capable of supporting the entire weight of the unit. Remember that the unit will be signifi- cantly heavier once it is fully loaded. It is extremely important that the unit is level. If it is not level, the water will not flow over the ice mold evenly. This can cause a reduction in ice rate, uneven sized cubes or water spilling into the storage area which will cause the ice in th
Краткое содержание страницы № 12
30005_CLRCO2075 User Manual 8/22/03 4:24 PM Page 10 User’s Manual NOTE All U-Line units have a zero CABINET clearance for the door to OR WALL open (Figure 4). See BUILT- IN INSTALLATION for addi- tional clearance require- ments. DOOR SWING 0" NOTE CLEARANCE Stainless Steel models NEEDED require a minimum of UL124A 2-1/2" door handle clear- ance when installed against Figure 4 a wall. 6. Install and connect the water supply line. See CONNECTING THE WATER SUPPLY for installation requirements.
Краткое содержание страницы № 13
C 30005_CLRCO2075 User Manual 8/22/03 4:24 PM Page 11 BUILT-IN INSTALLATION Your U-Line product has been designed for either free-standing or built- in installation. When built-in, your U-Line product does not require addi- tional air space for top, sides or rear. However, the front grille must NOT be obstructed. CAUTION Do not install unit behind closed doors. Table 3. Built-in Cabinet Dimensions Unit Dimensions AB C 34-1/8" 23-15/16" 24" NOTE To ease unit installation and removal, it is rec
Краткое содержание страницы № 14
30005_CLRCO2075 User Manual 8/22/03 4:24 PM Page 12 User’s Manual CONNECTING THE WATER SUPPLY When connecting the water supply, follow these guidelines: • Review the local plumbing codes before you install the unit. • In most instances, the cold water supply will come from the basement through a hole in the floor. • The water pressure should be between 20 minimum and 120 maximum psi. • Install a shut-off valve in the 1/4 inch supply line. • Connect sufficient tubing to the unit to allow the u
Краткое содержание страницы № 15
30005_CLRCO2075 User Manual 8/22/03 4:24 PM Page 13 3. For recessed installations, allow extra water supply and drain line length to provide slack for easy removal from the recessed area (Figure 8). This will also safeguard against kinking the line. CLRCO005 Figure 8 NOTE After completing the installation, turn on the water and recheck water and drain connection for leaks. Apply addi- tional tightening if needed. DO NOT use thread sealing compound or tape. 4. Plug in the power cord. 5. G
Краткое содержание страницы № 16
30005_CLRCO2075 User Manual 8/22/03 4:24 PM Page 14 User’s Manual LEVELING THE UNIT It is extremely important that the unit is level. If it is not level, the water will not flow over the ice mold evenly. This can cause a reduction in ice rate, uneven sized cubes or water spilling into the storage area which will cause the ice in the bin to melt prematurely. Remember that floors near drains have a tendency to slope towards the drain. 1. Use a level to check the levelness of the ice maker from
Краткое содержание страницы № 17
30005_CLRCO2075 User Manual 8/22/03 4:24 PM Page 15 2. If the ice maker is not level, adjust the feet on the corners of the unit as necessary (Figure 11). RAISE LOWER DWR005 Figure 11 3. Check the levelness after each adjustment and repeat the previous steps until the unit is level. REVERSING THE DOOR All U-Line units (except Stainless Steel models) may be left or right hand opening. The door opening is easily reversed by moving the hinge hard- ware to the opposite side (Figure 12). To revers
Краткое содержание страницы № 18
30005_CLRCO2075 User Manual 8/22/03 4:24 PM Page 16 User’s Manual 1. Remove top hinge screw pin 3. Remove top hinge (3 screws), (7/64" Allen wrench) from reinstall hinge screw pin, and cabinet (Figure 13). Remove remount on opposite side door by tilting forward and BOTTOM (Figure 15). lifting off bottom hinge pin. HINGE SCREW PIN UL313 Figure 15 UL310 4. Remove the two door closers from the existing bottom hinge Figure 13 and install as shown on the new bottom hinge location 2. Remove p
Краткое содержание страницы № 19
30005_CLRCO2075 User Manual 8/22/03 4:24 PM Page 17 5. Remove existing bottom hinge (3 screws) and remount on opposite side TOP. Remove hinge screw pin. 6. With bottom of door facing up, remove pivot plate (2 screws), flip over, and remount on opposite side of door (Figure 17). UL319 Figure 17 7. Holding door upright with top of door tilted forward, place hole of door pivot plate on bottom hinge screw pin (Figure 18). Be sure that the bosses on the closers align with holes in hinge and hing
Краткое содержание страницы № 20
30005_CLRCO2075 User Manual 8/22/03 4:24 PM Page 18 User’s Manual DOOR ADJUSTMENT Your door is aligned at the factory before shipment. Occasional re-adjustment may be necessary, especially if an Overlay Panel is installed. The following procedure will correct for up to 1/4" alignment. The door should never be flush with the top of the cabinet. Even when level, the top edge of the door will be 1/8" below the top of the cabinet (Figure 19). To adjust : 1. Compare the top edge of 1/8" the door