Inhaltszusammenfassung zur Seite Nr. 1
036-21630-001-B-0904
DESCRIPTION
YORK Sunline 2000™ heat pumps are convertible single
package units with a common cabinet and a common roof
TECHNICAL GUIDE
curb for the 3-6 ton sizes. The units were designed for light
commercial and commercial applications. They can easily be
installed on a roof curb, slab, roof jack or frame.
All units include:
SINGLE PACKAGE HEAT PUMP UNITS
• Powder Paint finish that meets ASTM-B-117 750 hour
BP 072
salt spray standards
6 NOMINAL TONS
• Permanently lu
Inhaltszusammenfassung zur Seite Nr. 2
036-21630-001-B-0904 TABLE OF CONTENTS DESCRIPTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 LIST OF TABLES Tbl. # Pg. # PRODUCT NOMENCLATURE . . . . . . . . . . . . . . . . . 3 FEATURES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 1 SOUND POWER RATING . . . . . . . . . . . . . . . . . . . . . . 15 FACTORY-INSTALLED OPTIONS . . . . . . . . . . . . . 12 2 CAPACITY RATINGS . . . . . . . . . . . . . . . . . . . . . . . . . 15 FIELD-INSTALLED ACCESSORIES . .
Inhaltszusammenfassung zur Seite Nr. 3
036-21630-001-B-0904 PRODUCT NOMENCLATURE 6 Ton Sunline Model Number Nomenclature B P 072 C00 A 2 A AA 1 Product Generation Product Category 1 = First Generation B = Heat Pump, Single Package Voltage Product Identifier 2 = 208/230-3-60 P = R-22 Hi. Effic. Heat Pump 4 = 460-3-60 5 = 575-3-60 Nominal Cooling Installation Options Additional Options Capacity - MBH (See Next Page) A = No Options Installed 072 = 6 Ton B = Option 1 C = Option 2 D = Options 1 & 2 E = Option 3 F = Option 4 G = Options 1
Inhaltszusammenfassung zur Seite Nr. 4
036-21630-001-B-0904 PRODUCT NOMENCLATURE - Continued 6T Sunline Model Number Nomenclature Standard Cabinet AA None AB Phase Monitor AC Coil Guard AD Dirty Filter Switch AE Phase Monitor & Coil Guard AF Phase Monitor & Dirty Filter Switch AG Coil Guard & Dirty Filter Switch AH Phase Monitor, Coil Guard, & Dirty Filter Switch AJ SS Drain Pan AK SS Drain Pan & Phase Monitor AL SS Drain Pan & Coil Guard AM SS Drain Pan & Dirty Filter Switch AN SS Drain Pan, Phase Monitor, Coil Guard & Dirty Filter
Inhaltszusammenfassung zur Seite Nr. 5
036-21630-001-B-0904 Standard Cabinet JR Johnson UNT Controller, DFS, APS, Technicoat Evap. & Cond Coils, Phase Monitor, & Coil Guard JS Johnson UNT Controller, DFS, APS, SS Drain Pan JT Johnson UNT Controller, DFS, APS, SS Drain Pan, Phase Monitor, & Coil Guard JU Johnson UNT Controller, DFS, APS, SS Drain Pan, & Technicoat Cond Coils JV Johnson UNT Controller, DFS, APS, SS Drain Pan, & Technicoat Evap Coil JW Johnson UNT Controller, DFS, APS, SS Drain Pan, & Technicoat Evap and Cond Coils JX J
Inhaltszusammenfassung zur Seite Nr. 6
036-21630-001-B-0904 Standard Cabinet TD Technicoat Condenser Coil & Dirty Filter Switch TE Technicoat Condenser Coil, Phase Monitor, & Coil Guard TF Technicoat Condenser Coil, Phase Monitor, & Dirty Filter Switch TG Technicoat Condenser Coil, Coil Guard, & Dirty Filter Switch TH Technicoat Condenser Coil, Phase Monitor, Coil Guard, & Dirty Filter Switch TJ Technicoat Evaporator Coil TK Technicoat Evaporator Coil & Phase Monitor TL Technicoat Evaporator Coil & Coil Guard TM Technicoat Evaporator
Inhaltszusammenfassung zur Seite Nr. 7
036-21630-001-B-0904 Standard Cabinet WF Intelli-Comfort w/ModLINC Controller, Technicoat Cond. Coil, & Phase Monitor WG Intelli-Comfort w/ModLINC Controller, Technicoat Cond. Coil, & Coil Guard WH Intelli-Comfort w/ModLINC Controller, Technicoat Cond. Coil, Phase Monitor, & Coil Guard WJ Intelli-Comfort w/ModLINC Controller, & Technicoat Evap. Coil WK Intelli-Comfort w/ModLINC Controller, Technicoat Evap. Coil, & Phase Monitor WL Intelli-Comfort w/ModLINC Controller, Technicoat Evap. Coil, & Co
Inhaltszusammenfassung zur Seite Nr. 8
036-21630-001-B-0904 Hinged Filter Door & Toolless Access Cabinet DX CPC Controller, DFS, APS, SS Drain Pan, Phase Monitor, Coil Guard, & Technicoat Evap and Cond Coils Hinged Filter Door & Toolless Access Panels EA Johnson UNT Controller with Dirty Filter Switch & Air Proving Switch, Hinged Filter Door & Toolless Access Panels EB Johnson UNT Controller, DFS, APS & Phase Monitor, Hinged Filter Door & Toolless Access Panels EC Johnson UNT Controller, DFS, APS & Coil Guard, Hinged Filter Door & T
Inhaltszusammenfassung zur Seite Nr. 9
036-21630-001-B-0904 Hinged Filter Door & Toolless Access Cabinet PC Novar ETC-3 Controller, DFS, APS & Coil Guard, Hinged Filter Door & Toolless Access Panels PD Novar ETC-3 Controller, DFS, APS, Phase Monitor, & Coil Guard, Hinged Filter Door & Toolless Access Panels PE Novar ETC-3 Controller, DFS, APS & Technicoat Cond. Coil, Hinged Filter Door & Toolless Access Panels PF Novar ETC-3 Controller, DFS, APS, Technicoat Cond. Coil, & Phase Monitor, Hinged Filter Door & Toolless Access Panels PG N
Inhaltszusammenfassung zur Seite Nr. 10
036-21630-001-B-0904 Hinged Filter Door & Toolless Access Cabinet QD Simplicity Intelli-Comfort Controller, Phase Monitor, & Coil Guard, Hinged Filter Door & Toolless Access Panels QE Simplicity Intelli-Comfort Controller, & Technicoat Cond. Coil, Hinged Filter Door & Toolless Access Panels QF Simplicity Intelli-Comfort Controller, Technicoat Cond. Coil, & Phase Monitor, Hinged Filter Door & Toolless Access Panels QG Simplicity Intelli-Comfort Controller, Technicoat Cond. Coil, & Coil Guard, Hin
Inhaltszusammenfassung zur Seite Nr. 11
036-21630-001-B-0904 • Fan Delays - Fan on and fan off delays are fully pro- FEATURES grammable and are independent of one another. All units are programmed with default values based All models are available with a wide variety of factory- upon their configuration of cooling and heat. mounted options such as electric heaters, phase monitor, convenience outlet, dirty filter switch, disconnect switch, • Safety Monitoring - The control board monitors the smoke detectors, and coil guards to mak
Inhaltszusammenfassung zur Seite Nr. 12
036-21630-001-B-0904 FIGURE 1 - UNIT CUTAWAY • ELECTRIC HEATERS - Wired for single point power FACTORY-INSTALLED OPTIONS supply. These nickel chromium heater elements are pro- • SINGLE INPUT ELECTRONIC ENTHALPY ECONO- vided with limit and automatic reset capability to prevent MIZERS - Includes a slide-in / plug-in damper assembly operation at excessive temperatures. with fully modulating spring-return motor actuator capa- • FILTER OPTIONS - Standard units are shipped with 1” ble of introduci
Inhaltszusammenfassung zur Seite Nr. 13
036-21630-001-B-0904 Air IAQ sensor. Construction mode operation, 365-day • BOTTOM DRAIN CONNECTION - An optional bottom real time clock with 7 day programming plus holiday drain connection is available for inside the curb connec- scheduling is built-in. Two different modes of demand tions for applications in cold environments to reduce ventilation are achieved through the INTELLI-Com- freezing drain lines. fort™using CO sensors. It uses an inside CO sensor to 2 2 • COIL GUARD - Customers c
Inhaltszusammenfassung zur Seite Nr. 14
036-21630-001-B-0904 Roof curbs are designed to fit inside the base rails of the return air panel. With horizontal ductwork, the accessory unit and include both a wood nailing strip and duct should be mounted on the return air duct. hanger supports. • ENTHALPY ACCESSORY CONTROL KIT - This kit • POWER EXHAUST - Our single input economizer contains the required components to convert a single options are available with power exhaust. Whenever the enthalpy economizer to dual enthalpy. outdoor ai
Inhaltszusammenfassung zur Seite Nr. 15
036-21630-001-B-0904 1 TABLE 1: SOUND POWER RATING -12 SOUND POWER (db 10 Watts) ESP BLOWER UNIT Octave Band Centerline Frequency (Hz) dB(A) CFM SIZE SWL @ dB(A) 2 IWG SPEED KW 63 125 250 500 1,000 2,000 4,000 8,000 10Ft. 072 2200 .3 - 1.35 87 87 77 70 72 65 60 55 77 44 1. These values have been accessed using a model of sound propagation from a point source into the hemispheric\free field. The dBA values provided are to be used for reference only. Calculation of dBA values cover matters of s
Inhaltszusammenfassung zur Seite Nr. 16
036-21630-001-B-0904 TABLE 3: BP072 COOLING CAPACITIES (6 TON) OUTDOOR AMBIENT TEMPERATURE 85°F 95°F RETURN AIR 1 1 GROSS SENSIBLE CAPACITY , MBH GROSS SENSIBLE CAPACITY , MBH 2 2 GROSS GROSS INPUT RETURN AIR DRY BULB TEMP. °F INPUT RETURN AIR DRY BULB TEMP. °F 1 1 CAP. POWER CAP. POWER WB MBH kW MBH kW CFM TEMP 86 83 80 77 74 71 68 86 83 80 77 74 71 68 °F 72 76.1 5.26 45.5 39.7 33.8 28.0 22.2 - - 72.6 5.80 43.1 38.0 32.9 27.7 22.6 - - 67 71.2 5.19 57.8 51.9 46.1 40.3 34.4 28.6 22.8 67.0 5.74
Inhaltszusammenfassung zur Seite Nr. 17
036-21630-001-B-0904 TABLE 3: BP072 COOLING CAPACITIES (6 TON) - CONTINUED OUTDOOR AMBIENT TEMPERATURE 125°F RETURN AIR 1 GROSS SENSIBLE CAPACITY , MBH 2 GROSS INPUT RETURN AIR DRY BULB TEMP. °F 1 CAP. POWER WB MBH kW CFM TEMP 86 83 80 77 74 71 68 °F 72 57.2 7.81 36.3 31.2 26.0 20.9 15.8 - - 67 50.2 7.66 46.2 41.1 36.0 30.8 25.7 20.6 15.4 1800 62 47.3 7.64 47.3 46.6 41.5 36.3 31.2 26.1 20.9 57 46.2 7.59 46.2 45.3 40.2 35.1 29.9 24.8 19.7 72 61.1 7.87 42.1 36.0 29.9 23.9 17.8 - - 67 53.7 7.7
Inhaltszusammenfassung zur Seite Nr. 18
036-21630-001-B-0904 TABLE 4: BP072 HEATING CAPACITIES CAP & OUTDOOR AIR TEMPERATURE (°F) (72% RH) CFM ID DB KW -10 0 10 20 30 40 50 60 MBH 14.733 23.633 32.534 41.435 50.336 59.237 68.137 77.038 55 KW 4.418 4.516 4.614 4.712 4.809 4.907 5.005 5.103 MBH 13.492 22.393 31.293 40.194 49.095 57.996 66.897 75.797 1800 70 KW 5.105 5.203 5.301 5.399 5.496 5.594 5.692 5.790 MBH 11.260 20.161 29.062 37.962 46.863 55.764 64.665 73.566 80 KW 5.559 5.657 5.755 5.853 5.950 6.048 6.146 6.244 MBH 16.565 25.4
Inhaltszusammenfassung zur Seite Nr. 19
036-21630-001-B-0904 TABLE 6: BELT DRIVE BLOWER MOTOR AND DRIVE DATA BELT 1 ADJUSTABLE MOTOR PULLEY FIXED BLOWER PULLEY MOTOR (NOTCHED) BLOWER MODEL RANGE OUTSIDE PITCH OUTSIDE PITCH PITCH SIZE DESIG- BORE DESIG- BORE DESIG- (RPM) HP FRAME DIA. DIA. DIA. DIA. LENGTH QTY. NATION (IN.) NATION (IN.) NATION (IN.) (IN.) (IN.) (IN.) (IN.) 6 TON 900/1250 1 1/2 56 1VL44 3.1-4.1 2.8-3.8 7/8 AK56 5.4 5.2 1 A36 37.3 1 1. All motors have solid bases and are inherently protected. these motors can b
Inhaltszusammenfassung zur Seite Nr. 20
036-21630-001-B-0904 TABLE 9: BP 072 ELECTRICAL DATA BELT DRIVE WITHOUT POWERED CONVENIENCE OUTLET Max OD ID Minimum Compressors Conv Model Fan Blower Electric Heater Heater Heater Circuit Fuse / Voltage Outlet 1 Tonnage Motor Motor Model No. kW Amps Ampacity BRKR RLA Each LRA Each Amps FLA FLA Amps Size NONE 0.0 0.0 31.5 40 2 2CE04510525 4.0 11.1 45.4 60 2 2CE04510725 5.6 15.5 50.9 60 208-3-60 19.2 146 2.3 5.2 0.0 2CE04511025 8.0 22.2 59.3 70 2CE04511525 11.9 33.0 72.8 80 2CE04512025 15.9 44.1