National Instruments NI 5102 user manual

User manual for the device National Instruments NI 5102

Device: National Instruments NI 5102
Category: Graphics Tablet
Manufacturer: National Instruments
Size: 0.1 MB
Added : 10/8/2014
Number of pages: 8
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for National Instruments NI 5102. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with National Instruments NI 5102.

For your convenience

If looking through the National Instruments NI 5102 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual National Instruments NI 5102 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual National Instruments NI 5102 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
National Instruments NI 5102 User manual - Online PDF
Advertisement
« Page 1 of 8 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual National Instruments NI 5102 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to National Instruments NI 5102. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

USER GUIDE

CALIBRATING THE NI 5102 WITH
CALIBRATION EXECUTIVE
Contents
Introduction............................................................................................. 2
What Is Calibration? ........................................................................ 2
Why Should You Calibrate? ............................................................ 2
How Often Should You Calibrate?.................................................. 2
Equipment and Other Test Requirements ............

Summary of the content on the page No. 2

Introduction This document contains information and step-by-step instructions for loading and running the calibration procedure for the NI 5102 using Calibration Executive. What Is Calibration? Calibration consists of verifying the measurement accuracy of a device and correcting for any measurement error. Verification is measuring the performance of a device and comparing the results to the factory specifications of the device. National Instruments calibrates every 5102 device at the factory. Du

Summary of the content on the page No. 3

Equipment and Other Test Requirements This section describes the equipment, documentation, software, and test conditions needed for calibration. Test Equipment Tables 1 and 2 list specifications for equipment you can use to calibrate your NI 5102 with Calibration Executive. Recommended Equipment Table 1 lists the equipment that National Instruments recommends for this procedure. Table 1. Required Equipment Specifications for NI 5102 Calibration Required Recommended Parameter Equipment Equipment

Summary of the content on the page No. 4

Alternative Equipment Table 2 contains a list of alternative equipment you can use to calibrate your NI 5102 with Calibration Executive. Table 2. Alternative Equipment Specifications for NI 5102 Calibration Required Recommended Parameter Equipment Equipment Measured Necessary Specifications Vertical Offset 0 VDC ±0.1 mV Calibrator Fluke 5700 Vertical Gain DC ±40 mV to ±4.5 V, ±0.1% Calibrator into 1 MΩ AC Coupling sine wave 9–13 Hz ±100 ppm, 1.8 Vpp ±2%into1MΩ High-Speed Signal Tektronix SG503 B

Summary of the content on the page No. 5

Software Complete the following steps to install Calibration Executive: 1. Make sure that your computer and monitor are powered on and that you have installed Windows 2000/NT/Me/9x. 2. Close all open applications. 3. Insert the installation CD into the CD-ROM drive. 4. Choose the Run option from the Start menu on the desktop task bar. 5. In the command line box, typex:\setup.exe (wherex is the letter of the CD-ROM drive you are using), and click OK. 6. Follow the instructions that appear in the

Summary of the content on the page No. 6

Calibration Procedures This section explains how to set up and run the Calibration Executive procedure. Using the Wavetek 9500 in automated mode, the calibration procedure takes approximately ten minutes. In manual mode, the procedure takes approximately 30 minutes. Using the alternative instruments in automated mode, the calibration procedure takes approximately 20 minutes. In manual mode, the procedure takes approximately 40 minutes. Connecting Your Calibrator, DMM, and NI 5102 The calibration

Summary of the content on the page No. 7

Viewing the Calibration Report When the procedure is finished, complete the following steps to view the calibration report: 1. Click View»Reports. 2. Select View to launch your browser and view your report. The calibration report appears as an printable HTML file. You have completed calibrating your NI 5102 with Calibration Executive. Note If your NI 5102 device fails after calibration, return the device to National Instruments for repair or replacement. © National Instruments Corporation 7 Cali

Summary of the content on the page No. 8

Technical Support Resources NI Web Support National Instruments Web support is your first stop for help in solving installation, configuration, and application problems and questions. Online problem-solving and diagnostic resources include frequently asked questions, knowledge bases, product-specific troubleshooting wizards, manuals, drivers, software updates, and more. Web support is available through the Technical Support section ofni.com Worldwide Support National Instruments has offices loca


Alternative user manuals
# User manual Category Download
1 National Instruments NI PCI-5114 User manual Graphics Tablet 0
2 National Instruments NI 5102 User manual Graphics Tablet 2
3 National Instruments NI 5911 User manual Graphics Tablet 0
4 National Instruments NI PXI-562X User manual Graphics Tablet 1
5 National Instruments PXI/PCI-5114 User manual Graphics Tablet 1
6 National Instruments NI PXI-5621 User manual Graphics Tablet 0
7 Sony S User manual Graphics Tablet 7
8 Sony SGPT11 User manual Graphics Tablet 8
9 Agilent Technologies DC282 User manual Graphics Tablet 2
10 Agilent Technologies DP110 User manual Graphics Tablet 1
11 Agilent Technologies DC135 User manual Graphics Tablet 0
12 Agilent Technologies DC211 User manual Graphics Tablet 1
13 Agilent Technologies DC122 User manual Graphics Tablet 1
14 Agilent Technologies DP1400 User manual Graphics Tablet 2
15 Agilent Technologies DP106 User manual Graphics Tablet 1