National Instruments NI 5102 user manual

User manual for the device National Instruments NI 5102

Device: National Instruments NI 5102
Category: Graphics Tablet
Manufacturer: National Instruments
Size: 0.7 MB
Added : 10/8/2014
Number of pages: 87
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for National Instruments NI 5102. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with National Instruments NI 5102.

For your convenience

If looking through the National Instruments NI 5102 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual National Instruments NI 5102 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual National Instruments NI 5102 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
National Instruments NI 5102 User manual - Online PDF
Advertisement
« Page 1 of 87 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual National Instruments NI 5102 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to National Instruments NI 5102. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

Computer-Based
Instruments
NI 5102 User Manual
High-Speed Digitizer
NI 5102 User Manual
June 2001 Edition
Part Number 321390D-01

Summary of the content on the page No. 2

Support Worldwide Technical Support and Product Information ni.com National Instruments Corporate Headquarters 11500 North Mopac Expressway Austin, Texas 78759-3504 USA Tel: 512 794 0100 Worldwide Offices Australia 03 9879 5166, Austria 0662 45 79 90 0, Belgium 02 757 00 20, Brazil 011 284 5011, Canada (Calgary) 403 274 9391, Canada (Montreal) 514 288 5722, Canada (Ottawa) 613 233 5949, Canada (Québec) 514 694 8521, Canada (Toronto) 905 785 0085, China (Shanghai) 021 6555 7838, China (ShenZhen)

Summary of the content on the page No. 3

Important Information Warranty The NI 5102 is warranted against defects in materials and workmanship for a period of one year from the date of shipment, as evidenced by receipts or other documentation. National Instruments will, at its option, repair or replace equipment that proves to be defective during the warranty period. This warranty includes parts and labor. The media on which you receive National Instruments software are warranted not to fail to execute programming instructions, due to d

Summary of the content on the page No. 4

Compliance FCC/Canada Radio Frequency Interference Compliance* Determining FCC Class The Federal Communications Commission (FCC) has rules to protect wireless communications from interference. The FCC places digital electronics into two classes. These classes are known as Class A (for use in industrial-commercial locations only) or Class B (for use in residential or commercial locations). Depending on where it is operated, this product could be subject to restrictions in the FCC rules. (In Canad

Summary of the content on the page No. 5

Canadian Department of Communications This Class B digital apparatus meets all requirements of the Canadian Interference-Causing Equipment Regulations. Cet appareil numérique de la classe B respecte toutes les exigences du Règlement sur le matériel brouilleur du Canada. Compliance to EU Directives Readers in the European Union (EU) must refer to the Manufacturer's Declaration of Conformity (DoC) for information** pertaining to the CE Mark compliance scheme. The Manufacturer includes a DoC for mo

Summary of the content on the page No. 6

Contents About This Manual Conventions Used in This Manual.................................................................................ix Related Documentation..................................................................................................x Chapter 1 Introduction About Your NI 5102 ......................................................................................................1-1 Acquiring Data with Your NI 5102 ........................................................

Summary of the content on the page No. 7

Contents Chapter 4 Hardware Overview I/O Connector ................................................................................................................ 4-2 Signal Connections........................................................................................................ 4-5 Serial Communications Port (AUX) ............................................................... 4-6 Analog Input............................................................................................

Summary of the content on the page No. 8

About This Manual TheNI5102isananaloginput device availableinPCI,PXI,ISA, PCMCIA, and USB form factors. This manual describes the installation and operation of these digitizers. Conventions Used in This Manual The following conventions are used in this manual: <> Angle brackets that contain numbers separated by an ellipsis represent a range of values associated with a bit or signal name—for example, DBIO<3..0>. » The » symbol leads you through nested menu items and dialog box options to a final

Summary of the content on the page No. 9

About This Manual NI 5102 NI 5102 is a generic term that denotes one or more of the NI 5102 (PCI), NI 5102 (PXI), NI 5102 (ISA), NI 5102 (PCMCIA), and NI 5102 (USB) devices. NI 5102 (ISA) Refers to the NI 5102 for ISA bus. NI 5102 (PCI) Refers to the NI 5102 for PCI bus. NI 5102 (PCMCIA) Refers to the NI 5102 for computers with a Type II PCMCIA slot. NI 5102 (PXI) Refers to the NI 5102 for PXI bus. NI 5102 (USB) Refers to NI 5102 for computers that are USB compatible. NI-DAQ NI-DAQ refers to the

Summary of the content on the page No. 10

1 Introduction This chapter describes the National Instruments (NI) 5102 and lists additional equipment. About Your NI 5102 Thank you for your purchase of an NI 5102. The NI 5102 family consists of five different devices tailored to your choice of bus: the PCI, the PXI, the ISA, the PCMCIA, and the universal serial bus (USB). Your NI 5102 has the following features:  Two 8-bit resolution analog input channels  Real-timesamplingrateof20MS/sto1kS/s; 1GS/srandom interleaved sampling (RIS)  15 MH

Summary of the content on the page No. 11

Chapter 1 Introduction To improve timing resolution for repetitive signals, you can use random interleaved sampling (RIS) on your NI 5102. This method of sampling allows you to view pretrigger data and achieve an effective sampling rate as high as 1 GS/s, 50 times the real-time sampling rate of the device. Detailed specifications of the NI 5102 devices are in Appendix A, Specifications. Acquiring Data with Your NI 5102 You can acquire data either programmatically by writing an application for yo

Summary of the content on the page No. 12

Chapter 1 Introduction Scope SFP C/C++ LabVIEW LabWindows/CVI Microsoft (Win 2000/NT/ (Win 2000/NT/ Visual Basic (Win 2000/NT/ (Win 2000/NT/ Excel Me/9x) Me/9x) Me/9x/3.1) Me/9x/3.1) DAQ VI NI-SCOPE ComponentWorks Measure Library Driver API NI-DAQ Driver Software PCI, PXI (Win 2000/NT/Me/9x/3.1) PCMCIA, ISA, USB (Win 2000/NT/Me/9x) NI 5102 Figure 1-1. The Relationship Between the Programming Environment, NI-DAQ, and Your Hardware Interactively Controlling your NI 5102 with the Scope Soft Front

Summary of the content on the page No. 13

Chapter 1 Introduction NI-SCOPE Driver The NI-SCOPE driver is the preferred choice to program your NI 5102. It provides flexibility and programmability in a standard full-featured instrument-driver format which lets you avoid low-level software calls and which works with LabVIEW, LabWindows/CVI, and conventional languages such as C/C++ and Visual Basic. To help you get started, NI-SCOPE comes with examples you can use or modify. You can find examples for these different ADEs:  LabVIEW— Go toPro

Summary of the content on the page No. 14

Chapter 1 Introduction Note NI 5102 digitizers use only the easy I/O interface under data acquisition in LabWindows/CVI. The easy I/O interface provides limited functionality in CVI. To use the NI 5102 to its full capabilities, use the NI-SCOPE driver as shown in Figure 1-1. Measurement Studio contains tools for data acquisition and device control built on NI-DAQ driver software. Measurement Studio provides a higher-level programming interface for building virtual instruments with Visual Basic,

Summary of the content on the page No. 15

Chapter 1 Introduction PXI-specific features, RTSI bus trigger, RTSI Clock, and Serial Communication are implemented on the J2 connector of the CompactPCI bus. Table 1-1 lists the J2 pins used by your NI 5102 (PXI) digitizer, which is compatible with any CompactPCI chassis with a sub-bus that does not drive these lines. Even if the sub-bus is capable of driving these lines, the NI 5102 (PXI) is still compatible as long as those pins on the sub-bus are disabled by default and are never enabled. D

Summary of the content on the page No. 16

2 Installation and Configuration This chapter describes how to unpack, install, and configure your NI 5102. What You Need to Get Started To set up and use your NI 5102, you will need the following: ❑ One of the following NI 5102 devices: – NI 5102 (PCI) – NI 5102 (PXI) – NI 5102 (ISA) – NI 5102 (PCMCIA) – NI 5102 (USB) ❑ NI-SCOPE Driver CD ❑ One of the following software packages and documentation: – LabVIEW – An application development environment (ADE) such as LabWindows/CVI, Visual C++, or Vi

Summary of the content on the page No. 17

Chapter 2 Installation and Configuration – NI 5102 (USB) NI 5102 (USB) power supply ❑ Vinyl pouch for storing cables and accessories for the NI 5102 (PCMCIA) only Unpacking ♦ NI 5102 (PCI, PXI, ISA) Your device is shipped in an antistatic package to prevent electrostatic damage to the device. Electrostatic discharge can damage several components on the device. To avoid such damage in handling the device, take the following precautions:  Ground yourself via a grounding strap or by holding a grou

Summary of the content on the page No. 18

Chapter 2 Installation and Configuration Installing the NI 5102 There are two main steps involved in installation: 1. Install the NI-SCOPE driver software. You use this driver to write programs to control your NI 5102 in different application development environments (ADEs). Installing NI-SCOPE also allows you to interactively control your NI 5102 with the Scope Soft Front Panel. 2. Install your NI 5102. For step-by-step instructions for installing NI-SCOPE and the NI 5102, see Where to Start wi

Summary of the content on the page No. 19

Chapter 2 Installation and Configuration Table 2-1. NI 5102 (USB) LED Patterns LED NI 5102 (USB) State Description On Configured State Your NI 5102 (USB) is configured. Off Offorinthe Your NI 5102 (USB) is turned off low-power, or in the low-power, suspend suspend mode mode. 2 Blinks Addressed state This pattern is displayed if the host computer detects your NI 5102 (USB) but cannot configure it because NI-DAQ is not installed properly or because there are no system resources available. If the N

Summary of the content on the page No. 20

3 Digitizer Basics This chapter explains basic information about using digitizers, including important terminology and use of the probe. Understanding Digitizers To understand how digitizers work, you should be familiar with the Nyquist theorem and how it affects analog bandwidth and sample rate. You should also understand vertical sensitivity, analog-to-digital converter (ADC) resolution, record length, and triggering options. Nyquist Theorem The Nyquist theorem states that a signal must be sam


Alternative user manuals
# User manual Category Download
1 National Instruments NI 5102 User manual Graphics Tablet 0
2 National Instruments NI PCI-5114 User manual Graphics Tablet 0
3 National Instruments NI 5911 User manual Graphics Tablet 0
4 National Instruments NI PXI-562X User manual Graphics Tablet 1
5 National Instruments PXI/PCI-5114 User manual Graphics Tablet 1
6 National Instruments NI PXI-5621 User manual Graphics Tablet 0
7 Sony S User manual Graphics Tablet 7
8 Sony SGPT11 User manual Graphics Tablet 8
9 Agilent Technologies DC282 User manual Graphics Tablet 2
10 Agilent Technologies DP110 User manual Graphics Tablet 1
11 Agilent Technologies DC135 User manual Graphics Tablet 0
12 Agilent Technologies DC211 User manual Graphics Tablet 1
13 Agilent Technologies DC122 User manual Graphics Tablet 1
14 Agilent Technologies DP1400 User manual Graphics Tablet 2
15 Agilent Technologies DP106 User manual Graphics Tablet 1