National Instruments NI PXI-5621 user manual

User manual for the device National Instruments NI PXI-5621

Device: National Instruments NI PXI-5621
Category: Graphics Tablet
Manufacturer: National Instruments
Size: 0.11 MB
Added : 10/8/2014
Number of pages: 9
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for National Instruments NI PXI-5621. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with National Instruments NI PXI-5621.

For your convenience

If looking through the National Instruments NI PXI-5621 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual National Instruments NI PXI-5621 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual National Instruments NI PXI-5621 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
National Instruments NI PXI-5621 User manual - Online PDF
Advertisement
« Page 1 of 9 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual National Instruments NI PXI-5621 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to National Instruments NI PXI-5621. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

NI PXI-5621 SPECIFICATIONS
High-Speed Digitizer
The NI PXI-5621 is a DC-coupled 64 MS/s 14-bit high-speed digitizer.
Except for its DC coupling, the PXI-5621 is functionally identical to the
PXI-5620. Refer to the NI PXI-562x User Manual for instructions on
installing and using your NI PXI-5621.
The NI PXI-5621 specifications are warranted at 0–50 °C ambient unless
otherwise specified, and include a 10 minute warm-up time from ambient
conditions.
General Specifications
Number of channels

Summary of the content on the page No. 2

DC offset.................................................±1 mV (calibrated) Analog bandwidth (–3 dB range) ...........0 Hz to 36 MHz Amplitude accuracy................................±0.5 dB VSWR 0–25 MHz........................................<1.5:1 25–32 MHz......................................<3:1 Dither (can be disabled) Frequency range ..............................150 Hz to 4 MHz Frequency Internal sample clock 16 Frequency ........................................64 MHz/n, where 1 < n <

Summary of the content on the page No. 3

Amplitude Typical Results –70.00 –80.00 –90.00 –100.00 –110.00 –120.00 –130.00 –140.00 0.0 5.0M 10.0M 15.0M 20.0M 25.0M 32.0M Frequency (Hz) Figure 1. Noise Density (Dither Disabled, Input Terminated) Average noise density (dither off).............................................. <–129 dBm/Hz Signal-to-noise ratio 9 dBm signal, full bandwidth.......... >62 dB Harmonic distortion (single tone, 0 dBm signal; includes aliased harmonic distortion) 4–15 MHz, dither enabled .............. <–77 dBm

Summary of the content on the page No. 4

Typical Results 0.00 –10.00 –20.00 –30.00 –40.00 –50.00 –60.00 –70.00 –80.00 –90.00 –100.00 –110.00 30.5M 30.6M 30.7M 30.8M 30.9M 31.0M 31.1M 31.2M 31.3M 31.4M 31.5M Frequency (Hz) Figure 2. Intermodulation Distortion Intermodulation distortion (2-tone, 0 dBm signals, 200 kHz separation) 4–15 MHz, dither enabled ...............<–86 dBm 0–32 MHz, dither disabled ..............<–78 dBm Residual responses (input terminated)....<–75 dBm NI PXI-5621 Specifications 4 ni.com Amplitude (dBm)

Summary of the content on the page No. 5

Typical Results 0.20 0.10 0.00 –0.10 –0.20 –0.30 –0.40 –0.50 –0.60 –0.70 –0.80 0.0 2.5 5.0 7.5 10.0 12.5 15.0 17.5 20.0 22.5 25.0 27.5 30.0 32.0 Frequency (MHz) Figure 3. Frequency Response (0.1–32 MHz) Frequency response (4–25 MHz) Relative (to response at 15 MHz) ... <±0.25 dB Absolute .......................................... <±0.6 dB Absolute (using calibration table)... <±0.5 dB © National Instruments Corporation 5 NI PXI-5621 Specifications Amplitude (dB)

Summary of the content on the page No. 6

Phase Typical Results 20.00E–9 18.00E–9 16.00E–9 14.00E–9 12.00E–9 10.00E–9 8.00E–9 6.00E–9 4.00E–9 2.00E–9 0.00E+0 –2.00E–9 0.0E+0 5.0E+6 10.0E+6 15.0E+6 20.0E+6 25.0E+6 32.0E+6 Frequency (Hz) Figure 4. Group Delay versus Frequency Group delay variation (5–25 MHz) ............................................9 ns pk–pk Group delay variation (0.5–30 MHz) .........................................26 ns pk–pk DDC Decimation rate.......................................32–4,096 DDC tuning resolution..

Summary of the content on the page No. 7

Triggering Modes..................................................... Immediate, software, digital Sources ................................................... PFI 1, PXI<0..7>, PXI STAR Export..................................................... PFI 1, PXI<0..7> Slope....................................................... Rising, falling Pretrigger depth...................................... Up to 32 MS Posttrigger depth .................................... Up to 32 MS Minimum pulse width ......

Summary of the content on the page No. 8

Environmental Specifications Warm-up time.........................................10 minutes Operating environment Ambient temperature.......................0–50 °C Humidity..........................................10–90%, noncondensing Storage environment Storage temperature.........................–20 to 70 °C Humidity..........................................5–95%, noncondensing Maximum altitude...................................2,000 meters Pollution Degree ..................................

Summary of the content on the page No. 9

Electromagnetic Compatibility CE, C-Tick, and FCC Part 15 (Class A) compliant Electrical emissions................................ EN 55011 Class A at 10 m FCC Part 15A above 1 GHz Electrical immunity................................ Evaluated to EN 61326:1997/A1:1998, Table 1 Note For full EMC compliance, you must operate this device with shielded cabling. In addition, all covers and filler panels must be installed. See the Declaration of Conformity (DoC) for this product for any additional


Alternative user manuals
# User manual Category Download
1 National Instruments NI 5102 User manual Graphics Tablet 0
2 National Instruments NI PCI-5114 User manual Graphics Tablet 0
3 National Instruments NI 5102 User manual Graphics Tablet 2
4 National Instruments NI 5911 User manual Graphics Tablet 0
5 National Instruments NI PXI-562X User manual Graphics Tablet 1
6 National Instruments PXI/PCI-5114 User manual Graphics Tablet 1
7 Sony S User manual Graphics Tablet 7
8 Sony SGPT11 User manual Graphics Tablet 8
9 Agilent Technologies DC282 User manual Graphics Tablet 2
10 Agilent Technologies DP110 User manual Graphics Tablet 1
11 Agilent Technologies DC135 User manual Graphics Tablet 0
12 Agilent Technologies DC211 User manual Graphics Tablet 1
13 Agilent Technologies DC122 User manual Graphics Tablet 1
14 Agilent Technologies DP1400 User manual Graphics Tablet 2
15 Agilent Technologies DP106 User manual Graphics Tablet 1