GE 500 user manual

User manual for the device GE 500

Device: GE 500
Category: Power Supply
Manufacturer: GE
Size: 0.36 MB
Added : 8/10/2013
Number of pages: 10
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for GE 500. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with GE 500.

For your convenience

If looking through the GE 500 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual GE 500 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual GE 500 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
GE 500 User manual - Online PDF
Advertisement
« Page 1 of 10 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual GE 500 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to GE 500. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1


g


GE Industrial Systems




™
Digital Energy ML Series
Uninterruptible Power Supply
350-500-700-1000 VA






























Manufactured by:

GE Digital Energy
General Electric Company Telephone +41 (0)91 / 850 51 51
CH – 6595 Riazzino (Locarno) Fax +41 (0)91 / 850 51 44
Switzerland Website www.gedigitalenergy.com



ML Series UPS Technology for the Digital World. ver 1.1 - GB

Summary of the content on the page No. 2

™ g GE Digital Energy ML Series GB USER MANUAL ™ Digital Energy ML Series Uninterruptible Power Supply Uninterruptible Power Supply Uninterruptible Power Supply Uninterruptible Power Supply 350 350--500 500--700 700--1000 VA 1000 VA 350 350--500 500--700 700--1000 VA 1000 VA Please read these instructions carefully before installation and start-up of the Digital Energy™ ML Series UPS. Keep this manual in a safe place for future reference. CONTENTS 1 INTRODUCTION

Summary of the content on the page No. 3

™ g GE Digital Energy ML Series 1 - Introduction 1.1 Introduction The GE (General Electric) Digital Energy™ ML Series UPS, an uninterruptible power supply, protects your equipment from all forms of power interference, including complete power failures. 1.2 Safety Rules • CAUTION: RISK OF ELECTRICAL SHOCK. The UPS contains batteries. The appliance outlets may be electrically live, even when the UPS is disconnected from the mains. • The UPS contains potentially hazar

Summary of the content on the page No. 4

™ g GE Digital Energy ML Series 2.2 Installation Procedure ML 350-700 ML 1000 1. Switch off your computer, and unplug it from the socket-outlet. 2. Disconnect the power cord from the computer (rating 250Vac/10A) and connect this cord to the male input socket (2) at the rear of the UPS (figures on the right show simplified ML 350-700 model). 3. Using the output cord provided, connect the computer to the appliance outl

Summary of the content on the page No. 5

™ g GE Digital Energy ML Series 3 - Operation 3.1 Start-up 3.1.1 Start-up, mains available 1 Press keypad 'ON' for 2 seconds LED ‘LINE’ (already blinking) will illuminate continuously now. 2 The equipment connected to the UPS can now be switched on. 3.1.2 Start-up, mains not available (‘battery start’) If the mains input is absent (power cord not connected, or mains failure): 1 Press keypad 'ON' for 2 seconds until LED ‘BAT’ illuminates. The UPS operates on battery:

Summary of the content on the page No. 6

™ g GE Digital Energy ML Series 3.3 Use: Status and Alarm Indications o status indications the operating mode ! low priority alarms abnormal operating situations !! high priority alarms situations in which the actual output voltage of the UPS is no longer guaranteed; immediate action should be taken RESET SITUATION LINE BAT BUZZER BUZZER Mains on. Green blinking Charger on O (3.3.1) UPS output off 1x /sec Normal Mains on. Green on

Summary of the content on the page No. 7

™ g GE Digital Energy ML Series 3.3.3 On battery The UPS uses the energy stored in the batteries: see chapter 7 ‘Batteries - autonomy’. The UPS will shutdown • after the batteries have been discharged (automatic restart), or • if keypad 'OFF' is pressed for >2 seconds (manual restart required) or • if a 'UPS shutdown' command is given by the computer (automatic restart). 3.3.4 Battery low (end of autonomy) The batteries are nearly discharged. Controlled shutdown of your computer eq

Summary of the content on the page No. 8

™ g GE Digital Energy ML Series 5 - Maintenance 5.1 General The UPS is virtually maintenance free: take care of proper environmental conditions and keep air inlets- outlets free of dust. Please read 2.1. 5.2 Fuses If the AC input fuse (1) is defective, be sure it is replaced by a compatible fuse from the same make and type. Fuse ratings: see chapter 7. 5.3 Batteries 5.3.1 General The service life of the battery is up to 6 years. As a healthy battery is criti

Summary of the content on the page No. 9

™ g GE Digital Energy ML Series 6 - Troubleshooting Whenever a malfunction occurs, first check external factors (e.g. connections, temperature, humidity or load) to determine whether the problem is caused by the unit itself or by its environment. Subsequently check the input fuse: it may be blown. If so: replace the fuse (see 5.2) and be sure that the UPS is not overloaded. The following chart is a simple troubleshooting checklist only. If the suggested solution does not succ

Summary of the content on the page No. 10

™ g GE Digital Energy ML Series 7 - Specifications ML Series model : 350 500 700 1000 Ratings Voltage Amperes (VA) / Watts (W) : 350 / 210 500 / 300 700 / 420 1000 / 600 Input AC input voltage (Vac) : 220 - 240 AC input voltage window (Vac) (mains) : 140 - 300V 140 - 300V 140 - 300V 160 - 265V Maximum AC input voltage (Vac) : 350 Minimum start-up AC voltage (Vac) : 150 150 150 170 Input frequency (Hz) : 50 Input frequency range : nominal ± 10 % Typical no-load power c


Alternative user manuals
# User manual Category Download
1 GE 1000-1500-2000-3000 VA User manual Power Supply 8
2 GE 350 User manual Power Supply 8
3 GE 600 - 1500 VA User manual Power Supply 9
4 GE 700 User manual Power Supply 17
5 GE CS300 User manual Power Supply 4
6 GE 225 User manual Power Supply 0
7 GE DEH-40417 User manual Power Supply 2
8 GE FVR-C9S-7UX User manual Power Supply 270
9 GE K 106168E User manual Power Supply 0
10 GE 300 User manual Power Supply 40
11 GE DIGITAL ENERGY LP11U User manual Power Supply 130
12 GE DIGITAL ENERGY LP 33 User manual Power Supply 356
13 GE ELECTROPHORESIS EPS 301 User manual Power Supply 5
14 GE K-106465A User manual Power Supply 1
15 GE User manual Power Supply 2
16 Sony AC U50A User manual Power Supply 5
17 Sony AC LS1 User manual Power Supply 2
18 Sony NP-FM30 User manual Power Supply 35
19 Sony NP FX101 User manual Power Supply 1
20 Sony NH-AAA-DA User manual Power Supply 2