GE ELECTROPHORESIS EPS 301 user manual

User manual for the device GE ELECTROPHORESIS EPS 301

Device: GE ELECTROPHORESIS EPS 301
Category: Power Supply
Manufacturer: GE
Size: 0.37 MB
Added : 8/10/2013
Number of pages: 38
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for GE ELECTROPHORESIS EPS 301. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with GE ELECTROPHORESIS EPS 301.

For your convenience

If looking through the GE ELECTROPHORESIS EPS 301 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual GE ELECTROPHORESIS EPS 301 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual GE ELECTROPHORESIS EPS 301 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
GE ELECTROPHORESIS EPS 301 User manual - Online PDF
Advertisement
« Page 1 of 38 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual GE ELECTROPHORESIS EPS 301 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to GE ELECTROPHORESIS EPS 301. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

Electrophoresis Power Supply
EPS 301
User Manual
Manuel d’Utilization
Bedienungsanleitung
Manual del usuario
Manuale dell’operatore
18-1130-18
Edition AB

Summary of the content on the page No. 2

Electrophoresis Power Supply - EPS 301 run HV on set view enter STOP Fig. 1. The front panel of the EPS 301. Figure 1. Le panneau avant de l’EPS 301. Abb. 1. Die Fronttafel des EPS 301. Figura 1. Panel frontal de la EPS 301. Figura 1. Pannello anteriore dell’EPS 301. Voltage 100-120/220-240 V AC Frequency 50/60 Hz Power 120 W 1.5 A Max MAINS Disconnect before servicing 100-120 220-240 Fig. 2. The rear panel of the EPS 301. Figure 2. Le panne

Summary of the content on the page No. 3

EPS 301 - User Manual Contents 1. Introduction . . . . . . . . . . . . . . . . . . . . . . 2 5. Operation. . . . . . . . . . . . . . . . . . . . . . . . 5 2. Safety information . . . . . . . . . . . . . . . . . 2 5.1 Connecting the . . . . . . . . . . . . . . . . . 2.1 Safety precautions . . . . . . . . . . . . . . 2 electrophoresis unit(s) . . . . . . . . . . . 5 2.2 Built-in safety features . . . . . . . . . . . 2 5.2 Programming. . . . . . . . . . . . . . . . . . 5 3. Unpacking and installat

Summary of the content on the page No. 4

EPS 301 - User Manual 1. Introduction The GE Healthcare Electrophoresis Power Supply EPS 301 is a high quality, high precision and safe power supply for electrophoresis applications that require a maximum of 300 volts, 400 mA and 80 W. EPS 301 is primarily designed for the following techniques: 1. Submarine DNA electrophoresis 2. Electroblotting 3. Immuno electrophoresis 4. Mini polyacrylamide gel electrophoresis Electrophoresis separations can be controlled by voltage or current. The EPS 30

Summary of the content on the page No. 5

EPS 301 - User Manual 3. Unpacking and installation Unpacking Check the contents against the packing list supplied. Inspect for any damage that may have occurred during transit. Report any damage immediately to your local GE Healthcare representative and to the transport company concerned. Mains connection Select the appropriate voltage range, 100-120 or 220-240 V. See Fig. 2 inside front cover. Warning! If the power supply is connected to 220-240 V with the range set to 100-120 V, the instrume

Summary of the content on the page No. 6

EPS 301 - User Manual 4. Technical description 4.1 Materials The main components in the EPS 301 power supply are made of the following materials. Instrument box Aluminium Display holder Polypropene (PP). UL94V0 Keyboard Polyester Output sockets Acetalplastic (POM). UL94V0 Rubber feet Polyurethane 4.2 Front panel On the front panel there is a numerical display illustrated with the symbols, V, mA, and h.m., a keyboard with six membrane keys, a light emitting diode that lights when voltage is appli

Summary of the content on the page No. 7

EPS 301 - User Manual 4.5 Output sockets There are two sets of output sockets connected in parallel to allow two electrophoresis units to be connected and run at the same time, see Fig. 1 inside front cover. 4.6 Rear panel The rear panel is shown in Fig. 2, see inside front cover. On the rear panel there is: 1. A mains switch. Press in I to switch on the power to the power supply. Press 0 to switch off the power. 2. A socket for the mains cable. 3. A switch for voltage range. The left position

Summary of the content on the page No. 8

EPS 301 - User Manual View actual values Press VIEW in Run mode to change between the actual values for voltage, current or elapsed time. Press VIEW for more than three seconds to switch automatically between these values. Stop the automatic switching by pressing VIEW or RUN. View programmed values Press SET/ENTER to view the programmed values during a run. If the keyboard is idle for 4 seconds or you press RUN the display goes back to the actual values. Change parameters during a run When t

Summary of the content on the page No. 9

EPS 301 - User Manual set enter set enter set enter set enter run view view view view STOP view view view Fig. 3. Step-by-step summary of programming and running. 7

Summary of the content on the page No. 10

EPS 301 - User Manual 6. Maintenance Wipe the instrument regularly with a damp cloth. Let the instrument dry completely before use. All servicing should be entrusted to qualified personnel only. Please contact your local GE Healthcare representative for more service information. 7. Trouble shooting If an error occurs, either during a run or when switching on the power supply, the output is switched off if necessary and an error message will be displayed. The following messages can be displayed.

Summary of the content on the page No. 11

EPS 301 - User Manual 8. Technical specifications Regulation Maximum voltage and current with automatic cross-over at preset limits Output mode Contante Voltage: 0-300 V DC, Contante Current: 0-400 mA Maximum Power Output 80 W Programming range Voltage: 5-300 V DC Current: 10-400 mA Time: 00.01-23.59 h or off (- - - -) Output resolution Voltage: 1 V Current: 1 mA Programming resolution Voltage: 1 V Current: 1 mA Time: 1 min Accuracy Voltage: 4%, ± 2 V Current: 4%, ± 4 mA Timer: 0.1% ± 1 min L

Summary of the content on the page No. 12

EPS 301 - User Manual 10

Summary of the content on the page No. 13

EPS 301 - Manuel d’Utilisation Table des matières 1. Introduction . . . . . . . . . . . . . . . . . . . . . . 2 4.2 Écran d'affichage . . . . . . . . . . . . . . . 3 2. Renseignements concernant la sécurité . . 2 4.3 Clavier . . . . . . . . . . . . . . . . . . . . . . . 3 2.1 Précautions d'emploi . . . . . . . . . . . . 2 4.4 Prises (connecteurs) de sortie . . . . . . 4 2.2 Caractéristiques de sécurité . . . . . . . . 4.5 Panneau arrière . . . . . . . . . . . . . . . . 4 intrinsèques . . . . . .

Summary of the content on the page No. 14

EPS 301 - Manuel d’Utilisation 1. Introduction L’Unité d’Alimentation électrique d’Électrophorèse EPS 301 produite por GE Healthcare est une unité d’alimentation électrique de haute précision, de sécurité maximale et de grande qualité destinée aux applications d’électrophorèse qui nécessite un maximum de 300 volt, de 400 mA et de 80 W. L’EPS 301 a été étudiée principalement pour être utilisée dans les domaines suivants: 1. électrophorèse sous-marine des acides nucléiques (ADN, ARN) 2. électrotra

Summary of the content on the page No. 15

EPS 301 - Manuel d’Utilisation Branchement sur l’alimentation secteur Sélectionner la tension appropriée, 100-120 V ou 220-240 V; Figure 2 (voir verso de la page de couverture). Recommandation importante! Si l’unité d’alimentation électrique est branchée sur la tension secteur de 220-240 V, alors que le sélecteur de l’appareil est placé sur la tension de 100-120 V, l’instrument w risque d’être sérieusement endommagé. Employer le cordon d’alimentation secteur approprié et brancher une des extrémi

Summary of the content on the page No. 16

EPS 301 - Manuel d’Utilisation Les valeurs autorisées sont: tension 5-300 V, intensité 10-400 mA, durée 0:01-23:59 heures ou minuterie non-active - - - - (arrêt manuel de l’opération d’électrophorèse). UP/DOWN (/) / Cette touche permet de modifier la valeur des paramètres V, mA et h.m. pendant que le cadran d’affichage clignote. Lorsqu’on maintient une pression sur cette touche, on accélère le défilement des valeurs numériques. Une pression rapide sur / permet de modifier la valeur d’un incr

Summary of the content on the page No. 17

EPS 301 - Manuel d’Utilisation 5. Utilisation 5.1 Instructions simplifiées Dans cette section l’utilisateur trouvera en résumé les grandes lignes de la programmation et de l’utilisation de l’EPS 301. Voir Figure 3 et consulter les instructions simplifiées de l’EPS 301 qui accompagnent l’unité d’alimentation EPS 301. Nous vous recommandons de conserver ces instructions à côté de l’instrument. 1. Mettre l’interrupteur d’alimentation secteur en position ON (Marche). Le programme se met en mode «End»

Summary of the content on the page No. 18

EPS 301 - Manuel d’Utilisation Entrer en mode 1. Paramétrer la tension limite set programmation 5 -> 300 V enter avec confirmer + passer au set sélectionner avec paramètre suivant avec enter 2. Paramétrer le courant-limite 10 -> 400 mA sélectionner avec confirmer + passer au set paramètre suivant avec enter 3. Paramétrer la durée de 0:01 - 23:59 (Minuterie OFF = ——) confirmer + passer au sélectionner avec set paramètre suivant avec enter 4. Démarrer l’exécution Démarrer en run appuyant sur vie

Summary of the content on the page No. 19

EPS 301 - Bedienungsanleitung Inhaltsverzeichnis 1. Einleitung. . . . . . . . . . . . . . . . . . . . . . . . 2 4.2 Anzeige . . . . . . . . . . . . . . . . . . . . . . 3 2. Sicherheitsangaben . . . . . . . . . . . . . . . . . 2 4.3 Tastatur . . . . . . . . . . . . . . . . . . . . . . 3 2.1 Sicherheitsmaßnahmen . . . . . . . . . . 2 4.4 Ausgangsbuchsen . . . . . . . . . . . . . . . 4 2.2 Eingebaute Sicherheitsmerkmale . . . 2 4.5 Rückwand . . . . . . . . . . . . . . . . . . . . 4 3. Auspacken und

Summary of the content on the page No. 20

EPS 301 - Bedienungsanleitung 1. Einleitung Das Elektrophorese-Stromversorgungsgerät EPS 301 von GE Healthcare ist ein qualitativ hochwertiges, äußerst genaues und sicheres Stromversorgungsgerät für Elektrophoreseanwendungen, die eine Stromversorgung von maximal 300 Volt, 400 mA und 80 W benötigen. Das Modell EPS 301 wurde vornehmlich für die folgenden Arbeitsverfahren entwickelt: 1. Submarine-DNA-Elektrophorese 2. Elektroblotting 3. DNA-Fragmenttrennung (Gen-Navigator) 4. Immunelektrophorese 5.


Alternative user manuals
# User manual Category Download
1 GE 1000-1500-2000-3000 VA User manual Power Supply 8
2 GE 350 User manual Power Supply 8
3 GE 600 - 1500 VA User manual Power Supply 9
4 GE 700 User manual Power Supply 17
5 GE CS300 User manual Power Supply 4
6 GE 225 User manual Power Supply 0
7 GE DEH-40417 User manual Power Supply 2
8 GE FVR-C9S-7UX User manual Power Supply 270
9 GE K 106168E User manual Power Supply 0
10 GE 300 User manual Power Supply 40
11 GE 500 User manual Power Supply 1
12 GE DIGITAL ENERGY LP11U User manual Power Supply 130
13 GE DIGITAL ENERGY LP 33 User manual Power Supply 356
14 GE K-106465A User manual Power Supply 1
15 GE User manual Power Supply 2
16 Sony AC U50A User manual Power Supply 5
17 Sony AC LS1 User manual Power Supply 2
18 Sony NP-FM30 User manual Power Supply 35
19 Sony NP FX101 User manual Power Supply 1
20 Sony NH-AAA-DA User manual Power Supply 2