Heat & Glo LifeStyle ESCAPE 36DV user manual

User manual for the device Heat & Glo LifeStyle ESCAPE 36DV

Device: Heat & Glo LifeStyle ESCAPE 36DV
Category: Fire Pit
Manufacturer: Heat & Glo LifeStyle
Size: 0.75 MB
Added : 5/8/2013
Number of pages: 26
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Heat & Glo LifeStyle ESCAPE 36DV. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Heat & Glo LifeStyle ESCAPE 36DV.

For your convenience

If looking through the Heat & Glo LifeStyle ESCAPE 36DV user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Heat & Glo LifeStyle ESCAPE 36DV on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Heat & Glo LifeStyle ESCAPE 36DV to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Heat & Glo LifeStyle ESCAPE 36DV User manual - Online PDF
Advertisement
« Page 1 of 26 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Heat & Glo LifeStyle ESCAPE 36DV but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Heat & Glo LifeStyle ESCAPE 36DV. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

Model:
Installers Guide
Escape-36DV
Underwriters
Laboratories Listed
READ THIS MANUAL BEFORE INSTALLING OR
OPERATING THIS APPLIANCE. THIS INSTALLERS
WARNING: IF THE INFORMATION
GUIDE MUST BE LEFT WITH APPLIANCE FOR
FUTURE REFERENCE.
IN THESE INSTRUCTIONS IS NOT
FOLLOWED EXACTLY, A FIRE OR
EXPLOSION MAY RESULT CAUS-
WARNING: IMPROPER INSTALLA-
ING PROPERTY DAMAGE, PER-
TION, ADJUSTMENT, ALTERATION,
SONAL INJURY, OR DEATH. SERVICE OR MAINTENANCE CAN
CAUSE INJURY OR PROPERTY DAM-
- Do not store or

Summary of the content on the page No. 2

SAFETY AND WARNING INFORMATION These units MUST use one of the vent systems READ and UNDERSTAND all instructions carefully ! ! described in the Installing the Fireplace section of before starting the installation. FAILURE TO the Installers Guide. NO OTHER vent systems or FOLLOW these installation instructions may result components MAY BE USED. in a possible fire hazard and will void the warranty. This gas fireplace and vent assembly MUST be Prior to the first firing of the fireplace, READ the !

Summary of the content on the page No. 3

TABLE OF CONTENTS Safety and Warning Information ................................................. 2 u Service Parts Lists ...................................................................... 4 Section 1: Approvals and Codes................................................ 6 Appliance Certification .................................................................... 6 Installation Codes ........................................................................... 6 High Altitude Installations ...

Summary of the content on the page No. 4

Service Parts ESCAPE-36DV (NG, LP) Exploded Parts Diagram Beginning Manufacturing Date: 9-03 (GN, PL) Vue éclatée des pièces Ending Manufacturing Date: ______ 21 27 20 13 14 22 19 16 18 17 15 11 10 VELCRO 9 23 24 25 12 Log set assembly 26 3 5 2 4 7 6 8 Part number list on following page. * La liste des numéros de pièce se * trouve à la page suivante. 1 1 4

Summary of the content on the page No. 5

Service Parts List / Liste des pièces de rechange ESCAPE-36DV IMPORTANT: THIS IS DATED INFORMATION. The most current information is located on your dealers VIP site. When order- ing, supply serial and model numbers to ensure correct service parts. / IMPORTANT : L'information fournie dans cette brochure n'est valide que pendant une courte période. Les sites VIP des distributeurs disposent des renseignements les plus récents. Lors d'une commande, veuillez fournir les numéros de série et de modè

Summary of the content on the page No. 6

Approvals and Codes 1 Appliance Certification High Altitude Installations The Heat-N-Glo fireplace model discussed in this Installers U.L. Listed gas appliances are tested and approved with- Guide has been tested to certification standards and listed out requiring changes for elevations from 0 to 2,000 feet in by the applicable laboratories. the U. S. A. and in Canada. When installing this appliance at an elevation above 2,000 Certification feet, it may be necessary to decrease the input rating

Summary of the content on the page No. 7

Getting Started 2 The Heat-N-Glo Warranty will be voided by, and Heat-N-Glo Introducing the Heat-N-Glo Gas Fireplaces disclaims any responsibility for, the following actions: Heat-N-Glo direct vent gas fireplaces are designed to oper- • Installation of any damaged fireplace or vent system ate with all combustion air siphoned from outside of the component. building and all exhaust gases expelled to the outside. • Modification of the fireplace or direct vent system. The information contained in th

Summary of the content on the page No. 8

Ø8” 25-3/8” (203mm) (646mm) 20-7/8” 3-1/2” (532mm) (90mm) 12” (304mm) 1/2” (13mm) 1” 50-7/8” (25mm) (1292mm) GAS LINE 54-1/8” ACCESS (1375mm) 34-1/2” 35-1/2” 31” (876mm) (788mm) (900mm) 2-5/8” (66mm) 11-5/8” (295mm) 36” 4-1/4” (914mm) ELECTRICAL ACCESS (106mm) TOP VENT COLLARS RATNG PLATES AND LABELS GAS GAS LINE ACCESS CONTROLS Figure 1. Diagram of the ESCAPE-36DV 8

Summary of the content on the page No. 9

1” MIN. (25.4mm) B Installing the Fireplace A 3 Constructing the Fireplace Chase A chase is a vertical box-like structure built to enclose the gas fireplace and/or its vent system. Vertical vents that run E D on the outside of a building may be, but are not required to be, installed inside a chase. C CAUTION: TREATMENT OF FIRESTOP SPACERS AND CONSTRUCTION OF THE CHASE MAY VARY WITH THE 1/2” MIN. (13mm) TYPE OF BUILDING. THESE INSTRUCTIONS ARE NOT A B C D E SUBSTITUTES FOR THE REQUIREMENTS OF LOC

Summary of the content on the page No. 10

Step 2. Framing the Fireplace Fireplace framing can be built before or after the fireplace is CAUTION: MEASURE FIREPLACE DIMENSIONS AND set in place. Framing should be positioned to accommo- VERIFY FRAMING METHODS AND WALL COVERING date wall coverings and fireplace facing material. The dia- DETAILS BEFORE FRAMING. gram below shows framing reference dimensions. Shows center of 10” x 12” vent framing holes for top and rear venting. The center of the hole is one (1) inch (25.4mm) above the center

Summary of the content on the page No. 11

DVP90ST 4 6 12 DVP4 DVP6 DVP12 14-1/4 12-3/16 2 MAX. MIN. 24 36 DVP12A 48 9-7/8 DVP24 O 45.0 10-1/4 DVP45 DVP36 11-1/4 7-1/4 1-1/4 TYP DVP48 8-9/16 1/2 TYP 12-9/16 NOTE: PIPES OVERLAP 1-1/4 INCHES AT EACH JOINT. Figure 6. DVP-Series Direct Vent Component Specifications (5-inch inner pipe / 8-inch outer pipe) 11

Summary of the content on the page No. 12

Step 3. Installing the Vent System A. Vent System Approvals Identifying Vent Components These models are approved to use DVP-series direct vent The vent systems installed on this gas fireplace may in- pipe components and terminations (see Figures 6 and 7). clude one, two, or three 90° elbow assemblies. The rela- Approved vent system components are labeled for identifi- tionships of vertical rise to horizontal run in vent configura- cation. This pipe is tested and listed as an approved com- t

Summary of the content on the page No. 13

CAP STRAIGHT UP VERTICAL VENTING FLUE RESTRICTOR V (FT.) FLUE RESTRICTOR 40' MAX. (12.4 M) V NOTE: On vertical venting configurations install the vertical baffle found in your manual bag per the flue restrictor instructions in this section. Figure 9 2. The restrictor sits inside the 5” diameter collar in the bead area. Using a needle-nose pliers, insert the tips of the pliers into the two holes in the restric- tor plate. Squeeze the pliers to flex the plate. The edges of the plate will need to o

Summary of the content on the page No. 14

VENTING WITH ONE (1) 90° ELBOW V (FT.) H (FT.) 1.5' MIN. (.457m) 2.5' MAX. (.762m) 2' MIN. (.609m) 3' MAX. (.912m) 2.5' MIN. (.762m) 6' MAX. (1.82m) 3.5' MIN. (1.06m) 9' MAX. (2.73m) 4.5' MIN. (1.37m) 12' MAX. (3.64m) 5.5' MIN. (1.67m) 15' MAX. (4.55m) 6.5' MIN. (1.98m) 18' MAX. (5.46m) 7.5' MIN. (2.28m) 21' MAX. (6.37m) H 8.5' MIN. (2.59m) 24' MAX. (7.28m) V = 40’ MAX. (12.2m) V+H = 64’ MAX. (19.5m) H = 24' MAX. (7.28m) V H V NOTE: Must have a 12” minimum vertical vent

Summary of the content on the page No. 15

VENTING WITH THREE (3) 90° ELBOWS V (FT.) H (FT.) 1.5' MIN. (.457m) 2.5' MAX. (.762m) 2' MIN. (.609m) 3' MAX. (.912m) 2.5' MIN. (.762m) 6' MAX. (1.82m) 3.5' MIN. (1.06m) 9' MAX. (2.73m) 4.5' MIN. (1.37m) 12' MAX. (3.64m) NOTE: H + H = 24' MAX. (7.28m) 1 V + V + H + H = 64' MAX. (19.5m) 1 1 H 1 V 1 V H NOTE: Must have a 12” minimum vertical vent o before attaching a 90 elbow to the unit. V 1 H 1 V H V (FT.) H + H (FT.) 1 1.5' MIN. (.457m) 2.5' MAX. (.762m

Summary of the content on the page No. 16

B. Installing Vent Components NOTE: There must be NO INSULATION or other Venting Out the Top Vent combustibles inside the framed firestop opening. The glass must be taken off again for positioning the logs when the unit is finally installed in place and finished around it. Re-install the glass door. Attach vent system to the top 10" starting collars. INTERIOR 1. Attach the First Vent Component to the WALL SHIELD Starting Collars To attach the first vent component to the starting collars

Summary of the content on the page No. 17

If the area above the ceiling IS an attic, position and secure For Vertical Runs - One ceiling firestop is REQUIRED at the firestop on top of the previously framed hole. the hole in each ceiling through which the vent passes. To install firestops for vertical runs that pass through ceilings: NOTE: Keep insulation away from the vent pipe at least 1 inch (25mm). • Position a plumb bob directly over the center of the verti- cal vent component. • Mark the ceiling to establish the centerpoint of the

Summary of the content on the page No. 18

O N P G R v A H D Q (See Note 2) E v V B L U.S. B T v (3 FT) v B B v S S Electrical V V Service F v v M I D* v X A J or K V X = VENT TERMINAL = AIR SUPPLY INLET = AREA WHERE TERMINAL IS NOT PERMITTED V A = 12" .......................... clearances above grade, veran- K = 3 ft. (U.S.A.) (See Note 1) da, porch, deck or balcony 6 ft. (Canada) .......... clearance to a mechanical air supply inlet B = 12" .......................... clearances to window or door that may be opened, or to per- L** = 7

Summary of the content on the page No. 19

WARNING: MAJOR U.S. BUILDING CODES HORIZONTAL ! OVERHANG SPECIFY MINIMUM CHIMNEY AND/OR VENT HEIGHT ABOVE THE ROOF TOP. THESE MIN- IMUM HEIGHTS ARE NECESSARY IN THE INTER- 2 FT. 20 INCH MIN. VERTICAL MIN. EST OF SAFETY. SEE THE PREVIOUS DIAGRAM WALL FOR MINIMUM HEIGHTS, PROVIDED THE TERMI- LOWEST DISCHARGE NATION CAP IS AT LEAST 20 INCHES FROM A VER- OPENING TERMINATION TICAL WALL AND 2-FEET BELOW A HORIZONTAL CAP OVERHANG. X 12 NOTE: This also pertains to vertical vent systems in- stalled on

Summary of the content on the page No. 20

Step 5. Installing the Optional Heat-Zone Kit Step 6 The Gas Control System WARNING: THIS UNIT IS NOT FOR USE WITH ! SOLID FUEL. HEAT-ZONE KNOCKOUTS The type of gas control system used with this model is Intermittent Pilot Ignition. Intermittent Pilot Ignition System This system includes millivolt control valve, standing pilot, thermopile/thermocouple flame sensor, and piezo ignitor. WARNING: 110-120 VAC MUST NEVER BE ! CONNECTED TO A CONTROL VALVE IN A MILLIVOLT SYSTEM. WARNING: CONTINUOUS 11


Alternative user manuals
# User manual Category Download
1 Heat & Glo LifeStyle ESCAPE 36DV User manual Indoor Fireplace 1
2 Heat & Glo LifeStyle 8000TRD User manual Fire Pit 2
3 Aquatic Exotic Flames Natural Gas User manual Fire Pit 0
4 Athena Technologies A88028 User manual Fire Pit 0
5 Avalon Stoves Gas Stove & Fireplace User manual Fire Pit 2
6 Baxi Potterton 339 User manual Fire Pit 1
7 Blue Rhino WAD808WDNC User manual Fire Pit 1
8 Breckwell TRADITION SERIES P23 P23FSL User manual Fire Pit 1
9 Breckwell TRADITION SERIES P23 P23FSA User manual Fire Pit 4
10 Breckwell TRADITION SERIES P23 P23I User manual Fire Pit 1
11 Brinkmann Ranch& Grill User manual Fire Pit 0
12 Brinkmann Gas FirePit User manual Fire Pit 0
13 Bryant GAS FIRED 394U User manual Fire Pit 0
14 Char-Broil FIREBOWL 6501121 User manual Fire Pit 1
15 Charnwood FIREPIT User manual Fire Pit 0