Summary of the content on the page No. 1 
                    
                        30" (76.2 CM) AND 36" (91.4 CM) GAS DOWNDRAFT 
COOKTOP INSTALLATION INSTRUCTIONS 
INSTRUCTIONS D'INSTALLATION DE LA TABLE DE 
CUISSON À GAZ À ASPIRATION PAR LE BAS
 DE 30" (76,2 CM) ET DE 36" (91,4 CM) 
Table of Contents/Table des matières
COOKTOP SAFETY..................................................................................1 SÉCURITÉ DE LA TABLE DE CUISSON ............................................ 13
INSTALLATION REQUIREMENTS ........................................................
                    
                    Summary of the content on the page No. 2 
                    
                        WARNING: If the information in this manual is not followed exactly, a fire or explosion  may result causing property damage, personal injury or death. – Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this  or any other appliance. – WHAT TO DO IF YOU SMELL GAS: Do not try to light any appliance.  Do not touch any electrical switch.  Do not use any phone in your building.  Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier'
                    
                    Summary of the content on the page No. 3 
                    
                        INSTALLATION REQUIREMENTS ■ The cooktop should be installed in a location away from  strong draft areas, such as windows, doors and strong  Tools and Parts heating vents or fans. Gather the required tools and parts before starting installation.  ■ All openings in the wall or floor where cooktop is to be  Read and follow the instructions provided with any tools listed  installed must be sealed. here. ■ Cabinet opening dimensions that are shown must be used.  Tools needed Given dimensions are mini
                    
                    Summary of the content on the page No. 4 
                    
                        A Cabinet Dimensions B C D A D E B C F G H F G L I E N A. 30" (76.2 cm) F. 1¹¹⁄₁₆" (4.3 cm) recommended  minimum cabinet to motor  B. 12¹⁵⁄₁₆" (32.9 cm) centerline of H clearance cooktop to centerline of gas  M manifold pipe G. 12¹⁄₂" (31.8 cm) I K C. 4" (10.2 cm) H. 14" (35.6 cm) K J D. 6¹⁹⁄₃₂" (16.8 cm) I. 28¼" (71.4 cm) E. 18⁷⁄₁₆" (46.8 cm) M 36" (91.4 cm) Cooktop A A. 30" (76.2 cm) on 30" (76.2 cm) models 36" (91.4 cm) on 36" (91.4 cm) models B. Combustible area above countertop (shown by da
                    
                    Summary of the content on the page No. 5 
                    
                        For Best Performance: Cutout Dimensions ■ Use 26-gauge minimum galvanized or 25-gauge minimum  aluminum metal vent. Poor quality pipe fittings can reduce  airflow. Flexible metal vent is not recommended. B A NOTE: Local codes may require a heavier gauge material. ■ Metal duct may be reduced to 30-gauge galvanized steel or  26-gauge aluminized steel if allowed by local codes. This  D reduction is based on information in the International  C Residential Codes Section M1601.1 (2006 edition). E ■ Do
                    
                    Summary of the content on the page No. 6 
                    
                        Venting Methods Common venting methods are shown for a counter-mounted  Concrete Slab Installations - Exhaust Through Wall downdraft cooktop. The cooktop may be vented through the wall  or floor. B Option 1 - Roof Venting Option 2 - Wall Venting A D E B F      C N  G H M      I K L B J A. Wall cap B. 6" (15.2 cm) round metal vent C. 16" (40.6 cm) maximum D. 6" (15.2 cm) round PVC sewer pipe A E. 6" (15.2 cm) round metal vent F. 6" (15.2 cm) round PVC coupling A G. Concrete slab H. 6" (15.2 cm) r
                    
                    Summary of the content on the page No. 7 
                    
                        Example vent system Calculating Vent System Length wall cap 90˚ elbow To calculate the length of the system you need, add the equivalent  6 ft (1.8 m) feet (meters) for each vent piece used in the system. Vent Piece 6" (15.2 cm) Round 45° elbow 2.5 ft (0.8 m)  2 ft  (0.6 m) 90° elbow 5.0 ft (1.5 m) 1- 90° elbow = 5 ft (1.5 m) 8 ft (2.4 m) straight = 8 ft (2.4 m) 1 - wall cap = 0 ft (0 m) System length = 13 ft (3.9 m) 6" (15.2 cm) 0.0 ft wall cap (0.0 m) NOTE: Flexible vent is not recommended. Fl
                    
                    Summary of the content on the page No. 8 
                    
                        Gas Supply Requirements Flexible metal appliance connector: ■ If local codes permit, use a ¹⁄₂" or ³⁄₄" I.D. flexible stainless  WARNING steel tubing gas connector, designed by CSA to connect  the cooktop to the rigid gas supply line.  ■ A ½" male pipe thread is needed for connection to the  Explosion Hazard female pipe threads of the inlet to the cooktop pressure  regulator.  Use a new CSA International approved gas supply line. ■ Do not kink or damage the flexible metal tubing when  Install a 
                    
                    Summary of the content on the page No. 9 
                    
                        Burner Input Requirements Gas Supply Pressure Testing Input ratings shown on the model/serial rating plate are for Gas supply pressure for testing regulator must be at least  elevations up to 2,000 ft (609.6 m). 1" water column pressure above the manifold pressure shown on  the model/serial rating plate. For elevations above 2,000 ft (609.6 m), ratings should be reduced  at a rate of 4% for each 1,000 ft (304.8 m) above sea level (not Line pressure testing above ½ psi gauge (14" WCP) applicable 
                    
                    Summary of the content on the page No. 10 
                    
                        3. Insert the ³⁄₈" socket and extension into the hole and use the 4. Verify the “Top” label is positioned as shown. ratchet handle to loosen the nut half of a rotation. Repeat this  process for each of the 4 nuts. 4. With the nuts loosened, the blower exhaust scroll can be  easily rotated downward. A 5. Retighten each nut with the ³⁄₈" socket, extension and ratchet. A. Top label 6. Reinstall the 4 plastic plugs. 5. Follow steps 5 - 10 in the “Install Cooktop” section. To rotate blower motor: NOT
                    
                    Summary of the content on the page No. 11 
                    
                        Typical flexible connection.  Complete Connection 1. Open the manual shutoff valve in the gas supply line. The  valve is open when the handle is parallel to the gas pipe. A. Manifold entrance B. Gas pressure regulator A C. Use pipe-joint compound. B  D. Adapter (must have ½" male pipe  A thread) E. Flexible connector B F. Adapter A. Closed valve G. Use pipe-joint compound. B. Open valve C H. Manual gas shutoff valve D I. ½" or ¾" gas pipe 2. Test all connections by brushing on an approved noncor
                    
                    Summary of the content on the page No. 12 
                    
                        To adjust standard burners: The flame can be adjusted using the adjustment screw in the  Electronic Ignition System center of the valve stem. The valve stem is located directly  Initial lighting and gas flame adjustments underneath the control knob. This cooktop is equipped for electronic auto-reignition by means  If the “low” flame needs to be adjusted: of a spark igniter located at the rear of each burner. The burners  1. Light 1 burner and turn to lowest setting. are designed to light at any 
                    
                    Summary of the content on the page No. 13 
                    
                        SÉCURITÉ DE LA TABLE DE CUISSON Votre sécurité et celle des autres est très importante. Nous donnons de nombreux messages de sécurité importants dans ce manuel et sur votre appareil ménager. Assurez-vous de  toujours lire tous les messages de sécurité et de vous y conformer.  Voici le symbole d’alerte de sécurité. Ce symbole d’alerte de sécurité vous signale les dangers potentiels de décès et de blessures graves à vous  et à d’autres. Tous les messages de sécurité suivront le symbole d’alerte de
                    
                    Summary of the content on the page No. 14 
                    
                        Dans l’État du Massachusetts, les instructions d’installation suivantes sont applicables : ■  Les travaux d’installation et réparation doivent être exécutés par un plombier ou tuyauteur qualifié ou licencié, ou par le  personnel qualifié d’une entreprise licenciée par l’État du Massachusetts. ■  Si une vanne à boisseau sphérique est utilisée, elle doit comporter une manette “T”. ■  Si un conduit de raccordement flexible est utilisé, sa longueur ne doit pas dépasser 3 pi. EXIGENCES D'INSTALLATION
                    
                    Summary of the content on the page No. 15 
                    
                        Résidence mobile – Spécifications additionnelles à Table de cuisson de 36" (91,4 cm) respecter lors de l'installation L'installation de cette table de cuisson doit être conforme aux  dispositions de la norme Manufactured Home Construction and  A Safety Standard, Title 24 CFR, Part 3280 (anciennement Federal  Standard for Mobile Home Construction and Safety, Title 24, HUD  Part 280). Lorsque cette norme n'est pas applicable, utiliser la  norme Standard for Manufactured Home Installations, ANSI  A
                    
                    Summary of the content on the page No. 16 
                    
                        ■ Un dégagement minimum de 2" (5,1 cm) entre le moteur/ Dimensions du placard ventilateur et le placard est recommandé pour que le  refroidissement puisse s'effectuer correctement. Un  dégagement de 6" (15,2 cm) est recommandé pour avoir  A accés en cas de réparations. D Dimensions de l’ouverture à découper B B A C D F G L E C N E F H H M I K K J I M J G A. 30" (76,2 cm) sur les modèles de 30" (76,2 cm) A. 28⁵⁄₈" (72,7 cm) maximum sur les modèles de 30" (76,2 cm) 36" (91,4 cm) sur les modèles de
                    
                    Summary of the content on the page No. 17 
                    
                        ■ Le circuit d'évacuation doit comporter un clapet. Si la bouche Installations pour régions à climat froid de décharge murale ou par le toit comporte un clapet, ne pas  On devrait installer un clapet anti-reflux additionnel pour  utiliser le clapet fourni avec la hotte de cuisinière. minimiser le reflux d’air froid, et incorporer un élément non  métallique d’isolation thermique pour minimiser la conduction de  ■ Au niveau de chaque jointure du circuit d'évacuation, assurer  chaleur par l’intermé
                    
                    Summary of the content on the page No. 18 
                    
                        Installations dans dalle de béton - Évacuation à travers le mur Raccord de transition de 3¹⁄₄" x 4,5 pi (1,4 m) B 10" (8,3 cm x 25,4 cm) sur 6"  (15,2 cm) A D E F Raccord de transition de 6" 1 pi (0,3 m)      C N  (15,2 cm) à 3¹⁄₄" x 10"  G (8,3 cm x 25,4 cm) H M     I K Coude de transition à 90° de 5 pi (1,5 m) L 3¹⁄₄" x 10" (8,3 cm x 25,4 cm)  J à 6" (15,2 cm) A. Bouche de décharge murale B. Conduit métallique de dia. 6" (15,2 cm) C. 16" (40,6 cm) maximum D. Conduit PVC pour égout de dia. 6" (
                    
                    Summary of the content on the page No. 19 
                    
                        Spécifications électriques Spécifications de l'alimentation en gaz IMPORTANT : La table de cuisson doit être correctement reliée à  la terre en conformité avec les codes et règlements locaux en  AVERTISSEMENT vigueur, ou en l'absence de tels codes, avec le National Electrical  Code, ANSI/NFPA 70 ou le Code canadien des installations  électriques, CSA C22.1. Cette table de cuisson est dotée d'un système d'allumage  électronique qui ne fonctionnera pas en cas de branchement dans  une prise qui n'e
                    
                    Summary of the content on the page No. 20 
                    
                        Canalisation de gaz Détendeur de gaz ■ Installer une canalisation de gaz rigide de ¾" (1,9 cm) jusqu'à Le détendeur fourni avec cette table de cuisson doit être utilisé. La  l'emplacement d'installation de la table de cuisson. L'emploi pression d'alimentation du détendeur doit être comme suit pour un  d'une canalisation de plus petit diamètre sur un circuit plus fonctionnement correct : long peut causer une déficience du débit d'alimentation. On  Gaz naturel : doit utiliser un composé d'étanchéi